ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 21: DIRECT LOCAL DATA EXCHANGE
12-01-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
3.2 Abbreviations
4 Physical properties
4.1 Electrical current loop interface
4.2 Electrical interface V.24/V.28
4.3 Optical interface
4.3.1 Construction of the reading head
4.3.2 Characteristic data of the magnet
4.3.3 Arrangement of components in the tariff device
4.3.4 Alignment
4.3.5 Optical characteristics
5 Character transmission
5.1 Type of transmission
5.2 Transmission speed
5.3 Signal quality
5.4 Character format
5.5 Character code
5.6 Character security
6 Data transmission protocol
6.1 General
6.2 Calculation of the block check character
6.3 Message definitions
6.3.1 Request message
6.3.2 Identification message
6.3.3 Acknowledgement/option select message
6.3.4 Data message (except in programming mode)
6.3.5 Acknowledgement message
6.3.6 Repeat-request message
6.3.7 Programming command message
6.3.8 Programming command message using optional partial
blocks
6.3.9 Data message (programming mode)
6.3.10 Data message (programming mode) using optional partial
blocks
6.3.11 Error message (programming mode)
6.3.12 Break message (programming mode)
6.3.13 Block message (other protocols)
6.3.14 Explanations of message contents
6.4 Communication modes
6.4.1 Protocol mode A
6.4.2 Protocol mode B
6.4.3 Protocol mode C
6.4.4 Protocol mode D
6.4.5 Protocol mode E (other protocols)
6.4.6 Entering programming mode (unknown tariff device)
6.4.7 Partial block communication (optional, only in protocol
mode C)
6.5 Syntax diagrams
6.5.1 Readout mode
6.5.2 Programming mode
6.6 Data set structure
Annex A (normative) Flow chart for direct local data exchange
protocol, protocol mode C
Annex B (normative) Wake-up methods for battery-operated tariff
devices
Annex C (informative) Formatted codes
Annex D (informative) Levels of access - system security
Annex E (normative) METERING HDLC protocol using protocol mode E
for direct local data exchange
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Index
Specifies hardware and protocol specifications for local meter data exchange. In such systems, a hand- held unit (HHU) or a unit with equivalent functions is connected to a tariff device or a group of devices.
DevelopmentNote |
Indice de Classement: C44-103 PR NF EN 62056-21 MAY 2000. Supersedes NF EN 61107 (07/2003)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Standards | Relationship |
IEC 62056-21:2002 | Identical |
UNE-EN 62056-21:2003 | Identical |
BS EN 62056-21:2002 | Identical |
DIN EN 62056-21 : 2003 | Identical |
I.S. EN 62056-21:2002 | Identical |
EN 62056-21:2002 | Identical |
NBN EN 62056-21 : 2002 | Identical |
NF EN 62056-42 : 2003 | ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 42: PHYSICAL LAYER SERVICES AND PROCEDURES FOR CONNECTION-ORIENTED ASYNCHRONOUS DATA EXCHANGE |
NF EN 14236 : 2007 | ULTRASONIC DOMESTIC GAS METERS |
ISO 1155:1978 | Information processing Use of longitudinal parity to detect errors in information messages |
IEC TR 62051:1999 | Electricity metering - Glossary of terms |
NF EN 62056-46 : 2003 AMD 1 2008 | ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 46: DATA LINK LAYER USING HDLC PROTOCOL |
NF EN 62056-42 : 2003 | ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 42: PHYSICAL LAYER SERVICES AND PROCEDURES FOR CONNECTION-ORIENTED ASYNCHRONOUS DATA EXCHANGE |
NFZ 66 100 : 1992 FD | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - CHARACTER STRUCTURE FOR START/STOP AND SYNCHRONOUS CHARACTER ORIENTED TRANSMISSION |
NFZ 66 010 : 1992 FD | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - BASIC MODE CONTROL PROCEDURES FOR DATA COMMUNICATION SYSTEMS |
ISO 1745:1975 | Information processing Basic mode control procedures for data communication systems |
IEC 62056-42:2002 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange |
NF EN 62056-53 : 2008 | ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 53: COSEM APPLICATION LAYER |
ISO 1177:1985 | Information processing Character structure for start/stop and synchronous character oriented transmission |
IEC 62056-53:2006 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 53: COSEM application layer |
ISO/IEC 646:1991 | Information technology ISO 7-bit coded character set for information interchange |
NFC 01 300 : 2001 AMD 2 2017 | ELECTROTECHNICAL VOCABULARY - ELECTRICAL AND ELECTRONIC MEASUREMENTS AND MEASURING INSTRUMENTS - PART 311: GENERAL TERMS RELATING TO MEASUREMENTS - PART 312: GENERAL TERMS RELATING TO ELECTRICAL MEASUREMENTS - PART 313: TYPES OF ELECTRICAL MEASURING INSTRUMENTS - PART 314: SPECIFIC TERMS ACCORDING TO THE TYPE OF INSTRUMENT |
IEC 62056-46:2002+AMD1:2006 CSV | Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.