Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NF EN 61098 : 2008

Current

Current

The latest, up-to-date edition.

RADIATION PROTECTION INSTRUMENTATION - INSTALLED PERSONNEL SURFACE CONTAMINATION MONITORING ASSEMBLIES

Published date

12-01-2013

Sorry this product is not available in your region.

AVANT-PROPOS
1 Domaine d'application et objet
2 Références normatives
3 Termes et définitions
4 Classement des appareils
   4.1 Suivant le type de rayonnement à mesurer
   4.2 Suivant le type de surface à surveiller
   4.3 Suivant le type
   4.4 Classement synthétique
5 Caractéristiques de conception
   5.1 Position de l'utilisateur
   5.2 Mensurations de l'utilisateur
   5.3 Moyens de surveillance des mains
   5.4 Moyens de surveillance des pieds
   5.5 Moyens de surveillance corps entier
   5.6 Affichage
   5.7 Indicateurs sonores
   5.8 Durée du controle
   5.9 Facilité de décontamination
   5.10 Détecteurs utilisés
6 Performances exigées et procédures d'essai
   6.1 Procédures générales d'essai
   6.2 Fluctuations statistiques
   6.3 Sources de référence
   6.4 Nature des essais
   6.5 Utilisation de détecteurs à flux gazeux
7 Caractéristiques radiatives
   7.1 Variation de la réponse en fonction de la position
        de la source
   7.2 Bruit de fond
   7.3 Débit d'émission surfacique minimale détectable
   7.4 Variation de la réponse avec l'énergie
   7.5 Réponse aux autres rayonnements ionisants
   7.6 Essais de type et individuels de série des
        performances
   7.7 Linéarité de l'indication
8 Protection des surcharges
   8.1 Exigences
   8.2 Méthode d'essai
9 Disponibilité
   9.1 Temps de chauffage
   9.2 Panne d'alimentation
10 Conditions environnementales
   10.1 Température
   10.2 Humidité relative
   10.3 Pression atmosphérique
11 Alimentation
   11.1 Tension et fréquence
   11.2 Compatibilité électromagnétique
12 Stockage
13 Documentation
   13.1 Certificat
   13.2 Manuel d'utilisation et de maintenance
   13.3 Instructions d'utilisation
   13.4 Rapport d'essai de type
Annexe A (informative) Explication de la dérivation de
         la formule du taux d'émission surfacique
         minimum détectable
Annexe ZA (informative) Exemples d'essais supplémentaires
          possibles pour une caractérisation du volume
          sensible
Annexe ZB (informative) Sommation des informations de
          détecteurs proches
Annexe ZC (normative) Références normatives à d'autres
          publications internationales avec les publications
          européennes correspondantes

Applies to contamination warning assemblies and monitors used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or not.

DevelopmentNote
Indice de classement: C19-106. PR NF EN 61098 February 2007. (02/2007)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
BS EN 61098:2007 Identical
DIN EN 61098 : 2008 Identical
NBN EN 61098 : 2007 Identical
I.S. EN 61098:2007 Identical
EN 61098:2007 Identical

IEC 60038:2009 IEC standard voltages
IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
NF EN 61187 : 1995 ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION
IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
NF EN 61000 4-2 : 2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-2: TESTING AND MEASUREMENT TECHNIQUES - ELECTROSTATIC DISCHARGE IMMUNITY TEST
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
NF EN 60359 : 2003 ELECTRICAL AND ELECTRONIC MEASUREMENT EQUIPMENT - EXPRESSION OF PERFORMANCE
NF EN 61000 4-8 : 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
NFC 01 394 : 2007 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 394: NUCLEAR INSTRUMENTATION - INSTRUMENTS
ISO 8769-2:1996 Reference sources for the calibration of surface contamination monitors Part 2: Electrons of energy less than 0,15 MeV and photons of energy less than 1,5 MeV
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 7503-1:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles
NF EN 61000 4-6 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
NF EN 61000-4-3 : 2006 AMD 2 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
NFC 01 393 : 2004 ELECTROTECHNICAL VOCABULARY - PART 393: NUCLEAR INSTRUMENTATION - PHYSICAL PHENOMENA AND BASIC CONCEPTS
ISO 8769:2016 Reference sources Calibration of surface contamination monitors Alpha-, beta- and photon emitters
IEC 60777:1983 Terminology, quantities and units concerning radiation protection
IEC 60050-393:2003 International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more