NF EN 1366-9 : 2009

Current

Current

The latest, up-to-date edition.

FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 9: SINGLE COMPARTMENT SMOKE EXTRACTION DUCTS

Published date

12-01-2013

Sorry this product is not available in your region.

Avant-propos
Introduction
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Équipement d'essai
5 Conditions d'essai
6 Éprouvette d'essai
7 Installation de l'éprouvette d'essai
8 Conditionnement
9 Application de l'instrumentation
10 Procédure d'essai
11 Critères de performances
12 Rapport d'essai
13 Domaine d'application direct des résultats d'essai
Annexe A (informative) - Mesure du débit
         volumique/massique
Annexe B (informative) - Mesure de la teneur en oxygène
Annexe C (informative) - Utilisation de coefficients de
         correction pour la prise en compte de différents
         paramètres
Bibliographie

La présente partie de l'EN 1366 spécifie une méthode d'essai pour déterminer la résistance au feu des conduits d'extraction de fumées qui sont utilisés pour des applications relatives à un seul compartiment. Dans de telles applications, le système d'extraction de fumées vise à fonctionner seulement jusqu'à l'embrasement généralisé (600 degrés C en général). Cette méthode d'essai n'est valable que pour des conduits fabriqués avec des matériaux non combustibles (Euroclasse A1 et A2-s1, d0). Les essais ne s'appliquent qu'aux conduits à quatre faces et aux conduits circulaires.

DevelopmentNote
Indice de classement: P92-130-9. PR NF EN 1366-9 February 2005. (02/2005) PR NF EN 1366-9 December 2007. (12/2007)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
EN 1366-9:2008 Identical

FD CEN/TR 12101-4 : 2009 FD SMOKE AND HEAT CONTROL SYSTEMS - PART 4: INSTALLED SHEVS SYSTEMS FOR SMOKE AND HEAT VENTILATION
NF EN 15423 : 2008 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS

ISO 13943:2017 Fire safety — Vocabulary
EN 1366-1:2014 Fire resistance tests for service installations - Part 1: Ventilation ducts
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1751:2014 Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves
ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more