Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NBN EN 60439-5 : 2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR POWER DISTRIBUTION IN PUBLIC NETWORKS

Superseded date

01-04-2011

Published date

12-01-2013

Sorry this product is not available in your region.

Committees responsible
National foreword
Foreword
1 General
    1.1 Scope and object
    1.2 Normative references
2 Definitions
    2.1 General
    2.2 Constructional units of ASSEMBLIES
    2.3 External design of ASSEMBLIES
    2.5 Conditions of installation of ASSEMBLIES
    2.7 Gangways within ASSEMBLIES
3 Classification of ASSEMBLIES
4 Electrical characteristics of ASSEMBLIES
    4.9 Rated current (of a cable distribution
          cabinet)
5 Information to be given regarding the ASSEMBLY
    5.1 Name plates
6 Service conditions
    6.1 Normal service conditions
    6.2 Special service conditions
7 Design and construction
    7.1 Mechanical design
    7.2 Enclosure and degree of protection
    7.4 Protection against electric shock
    7.6 Switching devices and components installed
          in ASSEMBLIES
8 Test specifications
    8.1 Classification of tests
    8.2 Type tests
Annex A (normative)
Annex ZA (normative) Normative references to
         international publications with their
         corresponding European publications
Figures
1 - Typical distribution network
2 - Diagram of test to verify the resistance to
    static load
3 - Sandbag for test to verify the resistance to
    shock load
4 - Diagram of test to verify the resistance to
    shock load
5 - Diagram of test to verify the resistance to
    torsional stress
6 - Diagram of test to verify impact force
    withstand
7 - Diagram of test to verify the mechanical strength
    of doors
8 - Striker element for test of resistance to mechanical
    shock impacts induced by sharp-edged objects
9 - Typical test arrangement for mechanical strength
    of base
Tables
7 - List of additional verifications and tests
18 - Axial load to be applied to the inserts
A.1 - Minimum and maximum cross-sections of copper and
      aluminium conductors, suitable for connection
      (see 7.1.3.2)

Provides supplementary requirements for substation cable distribution boards (SCDBs) and cable distribution cabinets (CDCs), which are stationary, type-tested assemblies (TTA).

DevelopmentNote
Supersedes NBN EN 50300. (10/2007)
DocumentType
Standard
PublisherName
Belgian Standards
Status
Superseded
Supersedes

Standards Relationship
DIN EN 60439-5 : 2007 Identical
BS EN 60439-5:2006 Identical
EN 60439-5:2006 Identical
I.S. EN 60439-5:2006 Identical
UNE-EN 60439-5:2007 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.