N290.5-16
Current
The latest, up-to-date edition.
Requirements for electrical power and instrument air systems of CANDU nuclear power plants
Hardcopy , PDF
English, French
01-01-2016
Preface
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 General design considerations
5 Design requirements - Electrical power systems
6 Design requirements - Instrument air system
7 Qualification
Annex A (informative) - Sample electrical configuration using
a two group philosophy with a separate EPS system
Contains the design, procurement, qualification, construction, installation, testing, commissioning, and documentation of CANDU nuclear power plant electrical power and instrument air systems.
DevelopmentNote |
French Edition issued on 01-02-2017. (02/2017)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0400-2
|
Pages |
40
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the third edition of CSA N290.5, Requirements for electrical power and instrument air systems of CANDU nuclear power plants. It supersedes the previous editions, published in 2006 and 1990. Note: CANDU (CANada Deuterium Uranium) is a Registered trademark of Atomic Energy of Canada Ltd., used under exclusive license by Candu Energy Inc, a Member of the SNC-Lavalin Group. Changes to this edition include new requirements, guidance, and recommendations for beyond design basis accident requirements arising from the Fukushima Daiichi event including requirements for design extension conditions. Consistent with industry initiatives to further classify and subdivide the beyond design basis accident regime, this Standard has been updated to address design extension conditions to the extent they are applicable to electrical power and instrument air systems. Other requirements for beyond design basis accidents are addressed in CSA N290.16. The CSA N-Series Standards provide an interlinked set of requirements for the management of nuclear facilities and activities. The CSA N286 Standard provides overall direction to management to develop and implement sound management practices and controls, while the other CSA nuclear Standards provide technical requirements and guidance that support the management system. This Standard works in harmony with CSA N286 and does not duplicate the generic requirements of CSA N286; however, it can provide more specific direction for those requirements. This Standard reflects the operating experience of the Canadian nuclear power industry. Users of this Standard are reminded that the design, manufacture, construction, commissioning, operation, and decommissioning of nuclear facilities in Canada are subject to the provisions of the Nuclear Safety and Control Act and its supporting Regulations. Scope 1.1 This Standard covers the design, procurement, qualification, construction, installation, testing, commissioning, and documentation of CANDU nuclear power plant electrical power and instrument air systems. 1.2 Electrical power and instrument air systems of CANDU nuclear power plants include all structures, systems, and components that are necessary to meet the plant design requirements, including the requirements for design extension conditions (DECs). 1.3 Electrical power systems consist of the Class I, II, III, IV, and other electrical systems that are required to meet the plant design requirements. 1.4 Instrument air systems consist of the components of the plant instrument air system and other provisions to provide compressed gas that is necessary to meet the plant design requirements. 1.5 This Standard was developed specifically for CANDU nuclear power plant designs and satisfies the applicable requirements of CNSC REGDOC-2.5.2. 1.6 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
CSA N290.13 : 2005 | ENVIRONMENTAL QUALIFICATION OF EQUIPMENT FOR CANDU NUCLEAR POWER PLANTS |
CSA N290.0 & N290.1 PACKAGE : 2013 | CONSISTS OF N290.0-11, GENERAL REQUIREMENTS FOR SAFETY SYSTEMS OF NUCLEAR POWER PLANTS AND N290.1-13, REQUIREMENTS FOR THE SHUTDOWN SYSTEMS OF NUCLEAR POWER PLANTS |
N290.6-16 | Requirements for monitoring and display of nuclear power plant safety functions in the event of an accident |
CSA N293 : 2012 : INC : UPD 1 : 2017 : R201700 | FIRE PROTECTION FOR NUCLEAR POWER PLANTS |
CSA N293 : 2012(R2018) | FIRE PROTECTION FOR NUCLEAR POWER PLANTS |
CSA N293 : 2012 | FIRE PROTECTION FOR NUCLEAR POWER PLANTS |
CSA N290.0 & N290.3 PACKAGE : 2016 | CONSISTS OF N290.0-11, GENERAL REQUIREMENTS FOR SAFETY SYSTEMS OF NUCLEAR POWER PLANTS AND N290.3-16, REQUIREMENTS FOR THE CONTAINMENT SYSTEM OF NUCLEAR POWER PLANTS |
CSA N290.0 & N290.2 PACKAGE : 2017 | CONSISTS OF N290.0-17, GENERAL REQUIREMENTS FOR SAFETY SYSTEMS OF NUCLEAR POWER PLANTS AND N290.2-17, REQUIREMENTS FOR EMERGENCY CORE COOLING SYSTEMS OF NUCLEAR POWER PLANTS |
CSA N393:13 (R2018) | Fire protection for facilities that process, handle, or store nuclear substances |
CSA N287.1:14 (R2019) | General requirements for concrete containment structures for nuclear power plants |
CSA N287.3:14 (R2019) | Design requirements for concrete containment structures for nuclear power plants |
CSA N290.8 : 2015 | TECHNICAL SPECIFICATION REQUIREMENTS FOR NUCLEAR POWER PLANT COMPONENTS |
IEEE 1106-2015 | IEEE Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications |
CSA N286.7 : 2016 | QUALITY ASSURANCE OF ANALYTICAL, SCIENTIFIC, AND DESIGN COMPUTER PROGRAMS |
CSA N290.12 : 2014 | HUMAN FACTORS IN DESIGN FOR NUCLEAR POWER PLANTS |
CSA N287.8 : 2015 | AGING MANAGEMENT FOR CONCRETE CONTAINMENT STRUCTURES FOR NUCLEAR POWER PLANTS |
N285.0-12/N285.6 SERIES-12 | General requirements for pressure-retaining systems and components in CANDU nuclear power plants/Material Standards for reactor components for CANDU nuclear power plants |
CSA N293 : 2012 | FIRE PROTECTION FOR NUCLEAR POWER PLANTS |
CSA N290.16 : 2016 | REQUIREMENTS FOR BEYOND DESIGN BASIS ACCIDENTS |
N290.6-16 | Requirements for monitoring and display of nuclear power plant safety functions in the event of an accident |
IEEE 450-2010 REDLINE | IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications |
IEEE 1184-2006 | IEEE Guide for Batteries for Uninterruptible Power Supply Systems |
ISA 7.0.01 : 1996 | QUALITY STANDARD FOR INSTRUMENT AIR |
CSA N290.7 : 2014 | CYBER SECURITY FOR NUCLEAR POWER PLANTS AND SMALL REACTOR FACILITIES |
CSA N290.14 : 2015 | QUALIFICATION OF DIGITAL HARDWARE AND SOFTWARE FOR USE IN INSTRUMENTATION AND CONTROL APPLICATIONS FOR NUCLEAR POWER PLANTS |
IEEE 387-1995 | IEEE Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations |
CSA N290.0 & N290.3 PACKAGE : 2016 | CONSISTS OF N290.0-11, GENERAL REQUIREMENTS FOR SAFETY SYSTEMS OF NUCLEAR POWER PLANTS AND N290.3-16, REQUIREMENTS FOR THE CONTAINMENT SYSTEM OF NUCLEAR POWER PLANTS |
IEEE 1115-2014 | IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications |
IEEE 485-2010 | IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.