MIL-C-18312 Revision G:2013

Current

Current

The latest, up-to-date edition.

CAPACITOR, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), GENERAL SPECIFICATION FOR

Available format(s)

PDF

1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION

Specifies the general requirements for fixed capacitors with metallized (paper, paper-plastic or plastic film) dielectric, direct current, hermetically sealed in metal cases.

Committee
FSC 5910
DevelopmentNote
Inactive for New Design. (09/2001)
DocumentType
Standard
Pages
43
PublisherName
US Military Specs/Standards/Handbooks
Status
Current

BS EN 61709:2017 Electric components. Reliability. Reference conditions for failure rates and stress models for conversion
MIL-HDBK-217 Revision F:1991 RELIABILITY PREDICTION OF ELECTRONIC EQUIPMENT
15/30310531 DC : 0 BS EN 61709 ED 3.0 - ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION
I.S. EN 61709:2017 ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION
MIL-P-24423 Base Document:1970 PROPULSION AND AUXILIARY CONTROL CONSOLES AND ASSOCIATED CONTROL AND INSTRUMENTATION EQUIPMENT, NAVAL SHIPBOARD USE, BASIC DESIGN REQUIREMENTS
MIL-PRF-39022 Revision J:2015 Capacitor, Fixed, Metallized, Paper-Plastic Film or Plastic Film Dielectric, Direct and Alternating Current, (Hermetically Sealed in Metal or Ceramic Cases), Established Reliability, General Specification for
IEC 61709:2017 RLV Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
EN 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
MIL C 39022 : E CAPACITOR, FIXED, METALLIZED PAPER, PAPER-PLASTIC FILM, OR PLASTIC FILM DIELECTRIC DIRECT AND ALTERNATING CURRENT, HERMETICALLY SEALED IN METAL CASE) ESTABLISHED RELIABILITY, GEN. SPEC. FOR
MIL-C-18312-2 Revision D:2013 CAPACITORS, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), STYLE CH09
MIL-C-18312-3 Revision D:2013 CAPACITORS, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), STYLE CH12
IEC 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion

MIL-PRF-39022 Revision J:2015 Capacitor, Fixed, Metallized, Paper-Plastic Film or Plastic Film Dielectric, Direct and Alternating Current, (Hermetically Sealed in Metal or Ceramic Cases), Established Reliability, General Specification for
MIL-STD-202-211 Base Document:2015 METHOD 211, TERMINAL STRENGTH
MIL-STD-202-302 Base Document:2015 Method 302, Insulation Resistance
ANSI/NCSL Z540 3 : 2006(R2013) REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT
MIL-STD-202-305 Base Document:2015 Method 305, Capacitance
MIL-STD-202-101 Base Document:2015 Method 101, Salt Atmosphere (Corrosion)
MIL-STD-202-107 Base Document:2015 Method 107, Thermal Shock
MIL-STD-202-106 Base Document:2015 Method 106, Moisture Resistance
MIL-STD-202-301 Base Document:2015 Method 301, Dielectric Withstanding Voltage
MIL-C-18312-3 Revision D:2013 CAPACITORS, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), STYLE CH12
MIL-STD-202-104 Base Document:2015 Method 104, Immersion
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
MIL-C-18312-2 Revision D:2013 CAPACITORS, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), STYLE CH09
MIL-STD-202-105 Base Document:2015 Method 105, Barometric Pressure (Reduced)
MIL-STD-202-208 Base Document:2015 Method 208, Solderability
MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
MIL-STD-1285 Revision D:2004 MARKING OF ELECTRICAL AND ELECTRONIC PARTS
MIL-STD-202-201 Base Document:2015 Method 201, Vibration
MIL-STD-202-204 Base Document:2015 Method 204, Vibration, High Frequency
MIL-STD-202-112 Base Document:2015 METHOD 112, SEAL
MIL-STD-202-213 Base Document:2015 Method 213, Shock (Specified Pulse)

$34.82
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.