ISO Guide 35:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Reference materials — Guidance for characterization and assessment of homogeneity and stability
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
03-05-2024
English, French
21-08-2017
ISO/Guide 35:2017 explains concepts and provides approaches to the following aspects of the production of reference materials:
- the assessment of homogeneity;
- the assessment of stability and the management of the risks associated with possible stability issues related to the properties of interest;
- the characterization and value assignment of properties of a reference material;
- the evaluation of uncertainty for certified values;
- the establishment of the metrological traceability of certified property values.
The guidance given supports the implementation of ISO 17034. Other approaches may also be used as long as the requirements of ISO 17034 are fulfilled.
Brief guidance on the need for commutability assessment (6.11) is given in this document, but no technical details are provided. A brief introduction for the characterization of qualitative properties (9.6 to 9.10) is provided together with brief guidance on sampling such materials for homogeneity tests (Clause 7). However, statistical methods for the assessment of the homogeneity and stability of reference materials for qualitative properties are not covered. This document is also not applicable to multivariate quantities, such as spectral data.
Committee |
ISO/TC 334
|
DocumentType |
Guide
|
Pages |
105
|
PublisherName |
International Organization for Standardization
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
Standards | Relationship |
JIS Q 0035:2022 | Identical |
SA HB 19.35:2018 | Identical |
PD ISO GUIDE 35:2017 | Identical |
FD ISO GUIDE 35 : 2018 FD | Identical |
NEN NPR ISO GUIDE 35 : 2006 | Identical |
PKN ISO GUIDE 35 : 2018 | Identical |
ASTM D 6362 : 1998 : R2003 | Standard Practice for Certificates of Reference Materials for Water Analysis |
FD ISO GUIDE 34 : 2010 FD | GENERAL REQUIREMENTS FOR THE COMPETENCE OF REFERENCE MATERIAL PRODUCERS |
ASTM E 2296 : 2003 | Standard Practice for Silver Corrections in Metal Bearing Ores, Concentrates, and Related Metallurgical Materials by Fire Assay Slag Recycling and Cupel Proof Gravimetry |
PD 6532-5:1997 | Reference materials. Guide to the contents of certificates of reference materials Quality system guidelines for the production of reference materials |
02/101929 DC : DRAFT FEB 2002 | PREN 12697-38 - BITUMINOUS MIXTURES - TEST METHODS FOR HOT MIX ASPHALT - PART 38: TEST EQUIPMENT AND CALIBRATION |
BS EN ISO/IEC 17043:2010 | Conformity assessment. General requirements for proficiency testing |
BS ISO 16042:2007 | Iron ores. Guidelines for the use of certified reference materials (CRMs) |
OIML D 18 : 2008 | THE USE OF CERTIFIED REFERENCE MATERIALS IN FIELDS COVERED BY METROLOGICAL CONTROL EXERCISED BY NATIONAL SERVICES OF LEGAL METROLOGY. BASIC PRINCIPLES |
BS ISO 17992:2013 | Iron ores. Determination of arsenic content. Hydride generation atomic absorption spectrometric method |
BS ISO 14606:2015 | Surface chemical analysis. Sputter depth profiling. Optimization using layered systems as reference materials |
11/30214536 DC : 0 | BS EN ISO 13736 - DETERMINATION OF FLASH POINT - ABEL CLOSED-CUP METHOD |
BIS IS 15393-6 : 2003(R2009) | ACCURACY (TRUENESS AND PRECISION) OF MEASUREMENT METHODS AND RESULTS - PART 6: USE IN PRACTICE OF ACCURACY VALUES |
OIML G 1-100 : 2008 | EVALUATION OF MEASUREMENT DATA - GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
03/300854 DC : DRAFT JAN 2003 | ISO 3679 - DETERMINATION OF FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD |
15/30327269 DC : 0 | BS EN ISO 17034 - GENERAL REQUIREMENTS FOR THE COMPETENCE OF REFERENCE MATERIAL PRODUCERS |
13/30213813 DC : 0 | BS EN ISO 16140-1 - MICROBIOLOGY OF FOOD AND ANIMAL FEED - METHOD VALIDATION - PART 1: VOCABULARY |
NF EN ISO 15351 : 2010 | STEEL AND IRON - DETERMINATION OF NITROGEN CONTENT - THERMAL CONDUCTIMETRIC METHOD AFTER FUSION IN A CURRENT OF INERT GAS (ROUTINE METHOD) |
05/30116635 DC : DRAFT APR 2005 | BS ISO 12739 - ZINC SULFIDE CONCENTRATES - DETERMINATION OF ZINC CONTENT - IONEXCHANGE/EDTA TITRIMETRIC METHOD |
BS ISO 5725-4:1994 | Accuracy (trueness and precision) of measurement methods and results Basic methods for the determination of the trueness of a standard measurement method |
08/30182372 DC : DRAFT JULY 2008 | BS EN 15842 - FOODSTUFFS - DETECTION OF FOOD ALLERGENS - GENERAL CONSIDERATIONS AND VALIDATION OF METHODS |
BS ISO 4689-3:2017 | Iron ores. Determination of sulfur content Combustion/infrared method |
BS EN ISO 16664:2017 | Gas analysis. Handling of calibration gases and gas mixtures. Guidelines |
BS ISO 16664 : 2004 | GAS ANALYSIS - HANDLING OF CALIBRATION GASES AND GAS MIXTURES - GUIDELINES |
ISO Guide 31:2015 | Reference materials — Contents of certificates, labels and accompanying documentation |
03/300855 DC : DRAFT JAN 2003 | ISO 3680 - DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD |
BS EN 10315:2006 | Routine method for analysis of high alloy steel by X-ray fluorescence spectrometry (XRF) by using a near by technique |
ASTM D 6596 : 2000 : R2005 | Standard Practice for Ampulization and Storage of Gasoline and Related Hydrocarbon Materials |
BS ISO 13528:2015 | Statistical methods for use in proficiency testing by interlaboratory comparison |
CSA ISO/TR 10017 : 2003 : R2013 | GUIDANCE ON STATISTICAL TECHNIQUES FOR ISO 9001:2000 |
ASTM D 6362 : 1998 : R2013 | Standard Practice for Certificates of Reference Materials for Water Analysis |
PREN 3976 : 200P1 | AEROSPACE SERIES - TITANIUM AND TITANIUM ALLOYS - TEST METHOD - CHEMICAL ANALYSIS FOR THE DETERMINATION OF HYDROGEN CONTENT |
ISO 13658:2000 | Zinc sulfide concentrates Determination of zinc content Hydroxide precipitation and EDTA titrimetric method |
PREN ISO 13736 : DRAFT 2011 | DETERMINATION OF FLASH POINT - ABEL CLOSED-CUP METHOD |
I.S. EN 16339:2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
CEI UNI 70099 : 2010 | INTERNATIONAL VOCABULARY OF METROLOGY - BASIC AND GENERAL CONCEPTS AND ASSOCIATED TERMS (VIM) |
BS ISO 2597-2:2015 | Iron ores. Determination of total iron content Titrimetric methods after titanium(III) chloride reduction |
ISO/TS 10798:2011 | Nanotechnologies — Charaterization of single-wall carbon nanotubes using scanning electron microscopy and energy dispersive X-ray spectrometry analysis |
UNE-EN ISO/IEC 17043:2010 | Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010) |
CEI UNI EN ISO/IEC 17025 : 2008 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES |
ASTM E 2972 : 2015 | Standard Guide for Production, Testing, and Value Assignment of In-House Reference Materials for Metals, Ores, and Other Related Materials |
BS ISO 10204:2017 | Iron ores. Determination of magnesium. Flame atomic absorption spectrometric method |
I.S. EN ISO 15194:2009 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - REQUIREMENTS FOR CERTIFIED REFERENCE MATERIALS AND THE CONTENT OF SUPPORTING DOCUMENTATION |
ASTM D 8175 : 2018 | Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Pensky-Martens Closed Cup Tester |
ASTM C 1128 : 2018 : REDLINE | Standard Guide for Preparation of Working Reference Materials for Use in Analysis of Nuclear Fuel Cycle Materials |
ISO 6974-1:2012 | Natural gas — Determination of composition and associated uncertainty by gas chromatography — Part 1: General guidelines and calculation of composition |
BS EN 12697-38:2004 | Bituminous mixtures. Test methods for hot mix asphalt Test equipment and calibration |
BS EN ISO 10993-12:2012 | Biological evaluation of medical devices Sample preparation and reference materials |
ISO/IEC 17043:2010 | Conformity assessment — General requirements for proficiency testing |
UNE-EN ISO 13736:2013 | Determination of flash point - Abel closed-cup method (ISO 13736:2013) |
BS EN ISO 14111:1999 | Natural gas. Guidelines to traceability in analysis |
ISO 17511:2003 | In vitro diagnostic medical devices Measurement of quantities in biological samples Metrological traceability of values assigned to calibrators and control materials |
EN ISO 2719:2016 | Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016) |
DIN EN ISO 148-3:2017-04 | METALLIC MATERIALS - CHARPY PENDULUM IMPACT TEST - PART 3: PREPARATION AND CHARACTERIZATION OF CHARPY V-NOTCH TEST PIECES FOR INDIRECT VERIFICATION OF PENDULUM IMPACT MACHINES (ISO 148-3:2016) |
EN ISO 148-3:2016 | Metallic materials - Charpy pendulum impact test - Part 3: Preparation and characterization of Charpy V-notch test pieces for indirect verification of pendulum impact machines (ISO 148-3:2016) |
UNI EN ISO 10993-12 : 2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS |
ASTM E 1724 : 1995 | Standard Guide for Testing and Certification of Metal and Metal-Related Reference Materials |
ISO 10258:2018 | Copper sulfide concentrates — Determination of copper content — Titrimetric methods |
BS EN ISO 2592:2017 | Petroleum and related products. Determination of flash and fire points. Cleveland open cup method |
10/30215322 DC : 0 | BS EN ISO 6974-1 - NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 1: GENERAL GUIDELINES AND CALCULATION OF COMPOSITION |
ISO 13545:2000 | Lead sulfide contentrates Determination of lead content EDTA titration method after acid digestion |
BS ISO 16878:2016 | Iron ores. Determination of metallic iron content. Iron(III) chloride titrimetric method |
ISO/TR 79:2015 | Reference materials - Examples of reference materials for qualitative properties |
ISO 13313:2017 | Iron ores Determination of sodium Flame atomic absorption spectrometric method |
06/30112308 DC : 0 | EN ISO 13530 - WATER QUALITY - GUIDANCE ON ANALYTICAL QUALITY CONTROL FOR CHEMICAL AND PHYSICOCHEMICAL WATER ANALYSIS |
ASTM D 6596:2000 | Standard Practice for Ampulization and Storage of Gasoline and Related Hydrocarbon Materials |
12/30237514 DC : 0 | BS ISO 13528 - STATISTICAL METHODS FOR USE IN PROFICIENCY TESTING BY INTERLABORATORY COMPARISONS |
ASTM E 2294 : 2003 | Standard Practice for Proof Silver Corrections in Metal Bearing Ores, Concentrates and Related Materials by Fire Assay Gravimetry |
ISO 16878:2016 | Iron ores Determination of metallic iron content Iron(III) chloride titrimetric method |
09/30179503 DC : DRAFT FEB 2009 | BS ISO 29301 - MICROBEAM ANALYSIS - ANALYTICAL TRANSMISSION ELECTRON MICROSCOPY - METHODS FOR CALIBRATING IMAGE MAGNIFICATION BY USING REFERENCE MATERIALS GIVING A PERIODIC DIFFRACTION PATTERN |
UNI EN 15842 : 2010 | FOODSTUFFS - DETECTION OF FOOD ALLERGENS - GENERAL CONSIDERATIONS AND VALIDATION OF METHODS |
10/30203803 DC : 0 | BS ISO 6974-2 - NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 2: UNCERTAINTY CALCULATIONS |
OIML V 2-200 : 2012 | INTERNATIONAL VOCABULARY OF METROLOGY - BASIC AND GENERAL CONCEPTS AND ASSOCIATED TERMS (VIM) |
BS ISO 15247:2015 | Zinc sulfide concentrates. Determination of silver content. Acid dissolution and flame atomic absorption spectrometric method |
BS ISO 13312:2017 | Iron ores. Determination of potassium. Flame atomic absorption spectrometric method |
ASTM E 826 : 2014 : REDLINE | Standard Practice for Testing Homogeneity of a Metal Lot or Batch in Solid Form by Spark Atomic Emission Spectrometry |
BS 2000-524(2004) : 2004 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - BS 2000-524: DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD |
UNI CEN/TR 10317 : 2009 | EUROPEAN CERTIFIED REFERENCE MATERIALS (EURONORM-CRMS) FOR THE DETERMINATION OF THE CHEMICAL COMPOSITION OF IRON AND STEEL PRODUCTS PREPARED UNDER THE AUSPICES OF THE EUROPEAN COMMITTEE FOR IRON AND STEEL STANDARDIZATION |
14/30231508 DC : 0 | BS ISO 13065 - SUSTAINABILITY CRITERIA FOR BIOENERGY |
UNI ISO/TS 21749 : 2009 | MEASUREMENT UNCERTAINTY FOR METROLOGICAL APPLICATIONS - REPEATED MEASUREMENTS AND NESTED EXPERIMENTS |
ISO Guide 32:1997 | Calibration in analytical chemistry and use of certified reference materials |
I.S. EN 10315:2006 | ROUTINE METHOD FOR ANALYSIS OF HIGH ALLOY STEEL BY X-RAY FLUORESCENCE SPECTROMETRY (XRF) BY USING A NEAR BY TECHNIQUE |
DIN ISO 5725-2:2002-12 | Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method (ISO 5725-2:1994 including Technical Corrigendum 1:2002) |
ISO 10378:2016 | Copper, lead and zinc sulfide concentrates Determination of gold and silver Fire assay gravimetric and flame atomic absorption spectrometric method |
DIN EN 15842:2010-06 | FOODSTUFFS - DETECTION OF FOOD ALLERGENS - GENERAL CONSIDERATIONS AND VALIDATION OF METHODS |
08/30190548 DC : DRAFT DEC 2008 | BS EN ISO 17054 - ROUTINE METHOD FOR ANALYSIS OF HIGH ALLOY STEEL BY X-RAY FLUORESCENCE SPECTROMETRY (XRF) BY USING A NEAR BY TECHNIQUE |
EN ISO 17511:2003 | In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials (ISO 17511:2003) |
DIN EN ISO 15351:2010-08 | Steel and iron - Determination of nitrogen content - Thermal conductimetric method after fusion in a current of inert gas (Routine method) (ISO 15351:1999) |
BS 2000-170(1998) : 1998 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - PETROLEUM PRODUCTS AND OTHER LIQUIDS - DETERMINATION OF FLASH POINT - ABEL CLOSED CUP METHOD |
BS 2000-450(2000) : 2000 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - DIESEL FUEL - ASSESSMENT OF LUBRICITY USING THE HIGH-FREQUENCY RECIPROCATING RIG (HFRR) - TEST METHOD |
BS ISO 16700:2004 | Microbeam analysis. Scanning electron microscopy. Guidelines for calibrating image magnification |
07/30157023 DC : 0 | BS EN ISO 15194 - IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - REQUIREMENTS FOR CERTIFIED REFERENCE MATERIALS AND THE CONTENT OF SUPPORTING DOCUMENTATION |
I.S. EN ISO 17511:2003 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN BIOLOGICAL SAMPLES - METROLOGICAL TRACEABILITY OF VALUES ASSIGNED TO CALIBRATORS AND CONTROL MATERIALS |
DIN EN ISO 16664:2016-07 (Draft) | GAS ANALYSIS - HANDLING OF CALIBRATION GASES AND GAS MIXTURES - GUIDELINES (ISO 16664:2017) |
ASTM D 6596 : 2000 : R2016 | Standard Practice for Ampulization and Storage of Gasoline and Related Hydrocarbon Materials |
ISO 12739:2006 | Zinc sulfide concentrates — Determination of zinc — Ion-exchange/EDTA titrimetric method |
BS EN ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories |
I.S. EN ISO 16140-1:2016 | MICROBIOLOGY OF THE FOOD CHAIN - METHOD VALIDATION - PART 1: VOCABULARY (ISO 16140-1:2016) |
UNE-ISO/IEC GUIA 98-3:2012 IN | Uncertainty of measurement - Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
UNE-EN ISO 16140-1:2016 | Microbiology of the food chain - Method validation - Part 1: Vocabulary (ISO 16140-1:2016) |
NF EN 15842 : 2010 | FOODSTUFFS - DETECTION OF FOOD ALLERGENS - GENERAL CONSIDERATIONS AND VALIDATION OF METHODS |
ASTM D 6362 : 1998 : R2008 | Standard Practice for Certificates of Reference Materials for Water Analysis |
NF ISO 16700 : 2006 | MICROBEAM ANALYSIS - SCANNING ELECTRON MICROSCOPY - GUIDELINES FOR CALIBRATING IMAGE MAGNIFICATION |
I.S. EN ISO 148-3:2016 | METALLIC MATERIALS - CHARPY PENDULUM IMPACT TEST - PART 3: PREPARATION AND CHARACTERIZATION OF CHARPY V-NOTCH TEST PIECES FOR INDIRECT VERIFICATION OF PENDULUM IMPACT MACHINES (ISO 148-3:2016) |
ASTM E 2295 : 2013 : REDLINE | Standard Practice for Fire Assay Silver Corrections in Analysis of Metal Bearing Ores, Concentrates, and Related Metallurgical Materials by Silver Determination in Slags and Cupels |
ASTM E 2294 : 2003 : R2008 : EDT 1 | Standard Practice for Proof Silver Corrections in Metal Bearing Ores, Concentrates and Related Materials by Fire Assay Gravimetry |
BS 2000-34(2016) : 2016 | DETERMINATION OF FLASH POINT - PENSKY-MARTENS CLOSED CUP METHOD (ISO 2719:2016) |
EN ISO 2592:2017 | Petroleum and related products - Determination of flash and fire points - Cleveland open cup method (ISO 2592:2017) |
ISO 15194:2009 | In vitro diagnostic medical devices Measurement of quantities in samples of biological origin Requirements for certified reference materials and the content of supporting documentation |
UNI EN ISO 13736 : 2013 | DETERMINATION OF FLASH POINT - ABEL CLOSED-CUP METHOD |
ISO 15633:2017 | Iron ores — Determination of nickel — Flame atomic absorption spectrometric method |
DIN EN 12697-38:2004-10 | Bituminous mixtures - Test methods for hot mix asphalt - Part 38: Common equipment and calibration; German version EN 12697-38:2004 |
DIN EN ISO 10993-12:2012-10 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
DIN EN ISO 6974-1:2012-11 | Natural gas - Determination of composition and associated uncertainty by gas chromatography - Part 1: General guidelines and calculation of composition (ISO 6974-1:2012) |
DIN EN ISO 6974-2:2012-11 | Natural gas - Determination of composition and associated uncertainty by gas chromatography - Part 2: Uncertainty calculations (ISO 6974-2:2012) |
BS EN ISO 12677:2011 | Chemical analysis of refractory products by X-ray fluorescence (XRF) Fused cast-bead method |
I.S. EN ISO 6974-1:2012 | NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 1: GENERAL GUIDELINES AND CALCULATION OF COMPOSITION (ISO 6974-1:2012) |
I.S. EN ISO 10723:2012 | NATURAL GAS - PERFORMANCE EVALUATION FOR ANALYTICAL SYSTEMS (ISO 10723:2012) |
I.S. EN ISO 13736:2013 | DETERMINATION OF FLASH POINT - ABEL CLOSED-CUP METHOD (ISO 13736:2013) |
I.S. EN ISO 6974-2:2012 | NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 2: UNCERTAINTY CALCULATIONS (ISO 6974-2:2012) |
DIN EN ISO 10723:2013-04 | NATURAL GAS - PERFORMANCE EVALUATION FOR ANALYTICAL SYSTEMS (ISO 10723:2012) |
I.S. EN ISO 10993-8:2000 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 8: SELECTION AND QUALIFICATION OF REFERENCE MATERIALS FOR BIOLOGICAL TESTS |
NF EN ISO 17511 : 2004 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN BIOLOGICAL SAMPLES - METROLOGICAL TRACEABILITY OF VALUES ASSIGNED TO CALIBRATORS AND CONTROL MATERIALS |
I.S. EN ISO 10993-12:2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS (ISO 10993-12:2012) |
I.S. EN ISO 2719:2016 | DETERMINATION OF FLASH POINT - PENSKY-MARTENS CLOSED CUP METHOD (ISO 2719:2016) |
I.S. EN ISO 3679:2015 | DETERMINATION OF FLASH NO-FLASH AND FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD (ISO 3679:2015) |
UNI ISO/TR 18532 : 2010 | Guide to the application of statistical methods for quality and standardization in the industrial sector |
PD 6532-3:2000 | Reference materials. Guide to the contents of certificates of reference materials Guide to the uses of certified reference materials |
PD 6532-5:2000 | Reference materials. Guide to the contents of certificates of reference materials General requirements for the competence of reference material producers |
17/30346182 DC : 0 | BS ISO 29301 - MICROBEAM ANALYSIS - ANALYTICAL TRANSMISSION ELECTRON MICROSCOPY - METHODS FOR CALIBRATING IMAGE MAGNIFICATION BY USING REFERENCE MATERIALS HAVING PERIODIC STRUCTURES |
ECA ILAC P14 : 2013 | ILAC POLICY FOR UNCERTAINTY IN CALIBRATION |
I.S. CWA 15261-2:2005 | MEASUREMENT UNCERTAINTIES IN MECHANICAL TESTS ON METALLIC MATERIALS - PART 2: THE EVALUATION OF UNCERTAINTIES IN TENSILE TESTING |
EN ISO 13736:2013 | Determination of flash point - Abel closed-cup method (ISO 13736:2013) |
PD ISO Guide 34:2009 | General requirements for the competence of reference material producers |
I.S. EN ISO 3680:2004 | DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD |
PD ISO/TR 9686:2017 | Direct reduced iron. Determination of carbon and/or sulfur. High-frequency combustion method with infrared measurement |
UNE-EN ISO 17034:2017 | General requirements for the competence of reference material producers (ISO 17034:2016) |
14/30301974 DC : 0 | BS ISO 10203 - IRON ORES - DETERMINATION OF CALCIUM - FLAME ATOMIC ABSORPTION SPECTROMETRIC METHOD |
BS ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Basic methods for the determination of repeatability and reproducibility of a standard measurement method |
BS ISO 15634:2015 | Iron ores. Determination of chromium content. Flame atomic absorption spectrometric method |
BS ISO 13547-1:2014 | Copper, lead, zinc and nickel sulfide concentrates. Determination of arsenic Iron hydroxide concentration and inductively coupled plasma atomic emission spectrometric method |
ASTM E 1724 : 1995 : R2001 | Standard Guide for Testing and Certification of Metal and Metal-Related Reference Materials (Withdrawn 2010) |
ISO/TS 14167:2003 | Gas analysis General quality assurance aspects in the use of calibration gas mixtures - Guidelines |
DIN EN 16339:2013-11 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
BS EN ISO 16140-1:2016 | Microbiology of the food chain. Method validation Vocabulary |
ISO/TR 9686:2017 | Direct reduced iron Determination of carbon and/or sulfur High-frequency combustion method with infrared measurement |
ASTM E 1732 : 2017-09 | TERMINOLOGY RELATING TO FORENSIC SCIENCE |
PD ISO/TR 79:2015 | Reference materials. Examples of reference materials for qualitative properties |
14/30281211 DC : 0 | BS ISO 11536 - IRON ORES - DETERMINATION OF LOSS ON IGNITION - GRAVIMETRIC METHOD |
03/317065 DC : DRAFT NOV 2003 | ISO/IEC 17025 - GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABS - AMENDMENT 1 |
BS ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results Intermediate measures of the precision of a standard measurement method |
BS ISO 22682:2017 | Iron ores. Determination of trace elements. Plasma spectrometric method |
BS EN 15842:2010 | Foodstuffs. Detection of food allergens. General considerations and validation of methods |
BS 3156-11.0.3(1997) : 1997 AMD 10655 | ANALYSIS OF FUEL GASES - METHODS FOR NON-MANUFACTURED GASES - GENERAL - GUIDELINES TO TRACEABILITY IN ANALYSIS OF NATURAL GAS |
BS ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results General principles and definitions |
BS 2000-523(2015) : 2015 | DETERMINATION OF FLASH NO-FLASH AND FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD |
BS ISO 20998-2:2013 | Measurement and characterization of particles by acoustic methods Guidelines for linear theory |
15/30301302 DC : 0 | BS EN ISO 2719 - DETERMINATION OF FLASH POINT - PENSKY-MARTENS CLOSED CUP METHOD |
UNE-ISO/IEC GUIA 99:2012 IN | International vocabulary of metrology. Basics and general concepts and associated terms (VIM) |
16/30328237 DC : 0 | BS ISO 22682 - IRON ORES - DETERMINATION OF TRACE ELEMENTS - PLASMA SPECTROMETRIC METHOD |
BS EN ISO 15351:2010 | Steel and iron. Determination of nitrogen content. Thermal conductimetric method after fusion in a current of inert gas (Routine method) |
PD ISO/TS 14411-1:2017 | Preparation of particulate reference materials Polydisperse material based on picket fence of monodisperse spherical particles |
PD CEN/TR 10317:2014 | European certified reference materials (EURONORM-CRMs) for the determination of the chemical composition of iron and steel products prepared under the auspices of the European Committee for Iron and Steel Standardization (ECISS) |
BIS IS/ISO/IEC 17025 : 2005 AMD 1 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES |
14/30296672 DC : 0 | BS ISO GUIDE 33 - REFERENCE MATERIALS - GOOD PRACTICE IN USING REFERENCE MATERIALS |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
BS ISO 12739:2006 | Zinc sulfide concentrates. Determination of zinc. Ion-exchange/EDTA titrimetric method |
ISO Guide 80:2014 | Guidance for the in-house preparation of quality control materials (QCMs) |
ASTM E 2296 : 2003 : R2008 : EDT 1 | Standard Practice for Silver Corrections in Metal Bearing Ores, Concentrates, and Related Metallurgical Materials by Fire Assay Slag Recycling and Cupel Proof Gravimetry |
ISO 13291:2006 | Zinc sulfide concentrates Determination of zinc Solvent extraction and EDTA titrimetric method |
PD 6461-3:1995 | General metrology Guide to the expression of uncertainty in measurement (GUM) |
S.R. CEN/TR 10317:2014 | EUROPEAN CERTIFIED REFERENCE MATERIALS (EURONORM-CRMS) FOR THE DETERMINATION OF THE CHEMICAL COMPOSITION OF IRON AND STEEL PRODUCTS PREPARED UNDER THE AUSPICES OF THE EUROPEAN COMMITTEE FOR IRON AND STEEL STANDARDIZATION (ECISS) |
ISO/TR 18336:2016 | Guidelines for good XRF laboratory practice for the iron ore industry |
ISO/TS 20460:2015 | Paper and board — Automated on-line testing — Metrological comparability between standardized measurements and output of on-line gauges |
ISO/TS 14411-1:2017 | Preparation of particulate reference materials — Part 1: Polydisperse material based on picket fence of monodisperse spherical particles |
UNE-EN 16339:2014 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
ISO Guide 30:2015 | Reference materials — Selected terms and definitions |
UNI EN ISO 15351 : 2010 | STEEL AND IRON - DETERMINATION OF NITROGEN CONTENT - THERMAL CONDUCTIMETRIC METHOD AFTER FUSION IN A CURRENT OF INERT GAS (ROUTINE METHOD) |
ASTM D 7911 : 2014 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
UNI CEI EN ISO/IEC 17043 : 2010 | CONFORMITY ASSESSMENT - GENERAL REQUIREMENTS FOR PROFICIENCY TESTING |
ISO Guide 34:2009 | General requirements for the competence of reference material producers |
ISO/TR 18532:2009 | Guidance on the application of statistical methods to quality and to industrial standardization |
ISO 17992:2013 | Iron ores — Determination of arsenic content — Hydride generation atomic absorption spectrometric method |
ISO 4689-3:2017 | Iron ores Determination of sulfur content Part 3: Combustion/infrared method |
ISO 10204:2017 | Iron ores — Determination of magnesium — Flame atomic absorption spectrometric method |
DIN EN ISO 3679:2015-06 | Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015) |
ISO 1523:2002 | Determination of flash point — Closed cup equilibrium method |
UNE-EN ISO 6974-2:2013 | Natural gas - Determination of composition and associated uncertainty by gas chromatography - Part 2: Uncertainty calculations (ISO 6974-2:2012) |
UNE-EN ISO 6974-1:2013 | Natural gas - Determination of composition and associated uncertainty by gas chromatography - Part 1: General guidelines and calculation of composition (ISO 6974-1:2012) |
BS EN ISO 3680:2004 | Methods of test for petroleum and its products. BS 2000-524. Determination of flash/no flash. Rapid equilibrium closed cup method |
UNE-EN ISO 12677:2012 | Chemical analysis of refractory products by X-ray fluorescence (XRF) - Fused cast-bead method (ISO 12677:2011) |
EN ISO 6974-2:2012 | Natural gas - Determination of composition and associated uncertainty by gas chromatography - Part 2: Uncertainty calculations (ISO 6974-2:2012) |
EN ISO 16140-1:2016 | Microbiology of the food chain - Method validation - Part 1: Vocabulary (ISO 16140-1:2016) |
UNI EN ISO 12677 : 2011 | CHEMICAL ANALYSIS OF REFRACTORY PRODUCTS BY X-RAY FLUORESCENCE (XRF) - FUSED CAST-BEAD METHOD |
UNI EN ISO 6974-2 : 2012 | NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 2: UNCERTAINTY CALCULATIONS |
EN ISO 15351:2010 | Steel and iron - Determination of nitrogen content - Thermal conductimetric method after fusion in a current of inert gas (Routine method) (ISO 15351:1999) |
UNI EN ISO 6974-1 : 2012 | NATURAL GAS - DETERMINATION OF COMPOSITION AND ASSOCIATED UNCERTAINTY BY GAS CHROMATOGRAPHY - PART 1: GENERAL GUIDELINES AND CALCULATION OF COMPOSITION |
UNI EN ISO 10723 : 2013 | NATURAL GAS - PERFORMANCE EVALUATION FOR ANALYTICAL SYSTEMS |
UNE-EN ISO 148-3:2017 | Metallic materials - Charpy pendulum impact test - Part 3: Preparation and characterization of Charpy V-notch test pieces for indirect verification of pendulum impact machines (ISO 148-3:2016) |
DIN EN ISO 148-3:2015-09 (Draft) | METALLIC MATERIALS - CHARPY PENDULUM IMPACT TEST - PART 3: PREPARATION AND CHARACTERIZATION OF CHARPY V-NOTCH TEST PIECES FOR INDIRECT VERIFICATION OF PENDULUM IMPACT MACHINES (ISO 148-3:2016) |
UNE-EN ISO 14189:2017 | Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration (ISO 14189:2013) |
ASTM D 93 : 2016-07 | TEST METHODS FOR FLASH POINT BY PENSKY-MARTENS CLOSED CUP TESTER |
BS EN ISO 15194:2009 | In vitro diagnostic medical devices. Measurement of quantities in samples of biological origin. Requirements for certified reference materials and the content of supporting documentation |
BS EN 16339:2013 | Ambient air. Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
I.S. EN ISO/IEC 17043:2010 | CONFORMITY ASSESSMENT - GENERAL REQUIREMENTS FOR PROFICIENCY TESTING |
PD ISO/TR 16476:2016 | Reference materials. Establishing and expressing metrological traceability of quantity values assigned to reference materials |
12/30271500 DC : 0 | BS ISO GUIDE 80 - GUIDANCE FOR IN-HOUSE PRODUCTION OF REFERENCE MATERIALS FOR QUALITY CONTROL (QCMS) |
06/30138176 DC : 0 | EN ISO 13736 - DETERMINATION OF FLASH POINT - ABEL CLOSED CUP METHOD |
17/30345272 DC : 0 | BS ISO 14167 - GAS ANALYSIS - GENERAL QUALITY ASPECTS AND METROLOGICAL TRACEABILITY OF CALIBRATION GAS MIXTURES |
DD ISO/TS 10798 : DRAFT JULY 2011 | NANOTECHNOLOGIES - CHARACTERIZATION OF SINGLEWALL CARBON NANOTUBES USING SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE X-RAY SPECTROMETRY ANALYSIS |
DIN EN ISO 15194:2009-10 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - REQUIREMENTS FOR CERTIFIED REFERENCE MATERIALS AND THE CONTENT OF SUPPORTING DOCUMENTATION |
BS EN ISO 148-3:2016 | Metallic materials. Charpy pendulum impact test Preparation and characterization of Charpy V-notch test pieces for indirect verification of pendulum impact machines |
13/30294275 DC : 0 | BS ISO GUIDE 30 - REFERENCE MATERIALS - SELECTED TERMS AND DEFINITIONS |
ISO/TR 16476:2016 | Reference materials — Establishing and expressing metrological traceability of quantity values assigned to reference materials |
BS ISO 11536:2015 | Iron ores. Determination of loss on ignition. Gravimetric method |
CEN/TR 10317:2014 | European certified reference materials (EURONORM-CRMs) for the determination of the chemical composition of iron and steel products prepared under the auspices of the European Committee for Iron and Steel Standardization (ECISS) |
09/30210426 DC : 0 | BS EN ISO 15351 - STEEL AND IRON - DETERMINATION OF NITROGEN CONTENT - THERMAL CONDUCTIMETRIC METHOD AFTER FUSION IN A CURRENT OF INERT GAS (ROUTINE METHOD) |
14/30316056 DC : 0 | BS ISO/GUIDE 31 - REFERENCE MATERIALS - CONTENTS OF CERTIFICATES, LABELS AND ACCOMPANYING DOCUMENTATION |
PD 6532-3:1992 | Reference materials. Guide to the contents of certificates of reference materials Guide to the uses of certified reference materials |
15/30317578 DC : 0 | BS ISO 16700 - MICROBEAM ANALYSIS - SCANNING ELECTRON MICROSCOPY - GUIDELINES FOR CALIBRATING IMAGE MAGNIFICATION |
PD ISO GUIDE 30:2015 | Reference materials. Selected terms and definitions |
16/30325304 DC : 0 | BS EN ISO 2592 - PETROLEUM AND RELATED PRODUCTS - DETERMINATION OF FLASH AND FIRE POINTS - CLEVELAND OPEN CUP METHOD |
BS ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results Use in practice of accuracy values |
ISO 16700:2016 | Microbeam analysis — Scanning electron microscopy — Guidelines for calibrating image magnification |
BS 2000-34(2002) : 2002 AMD 15248 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - DETERMINATION OF FLASH POINT - PENSKY-MARTENS CLOSED CUP METHOD |
PREN 45001 : DRAFT 1997 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES |
BS ISO 20998-3:2017 | Measurement and characterization of particles by acoustic methods Guidelines for non-linear theory |
ASTM D 6808 : 2002 : R2012 | Standard Practice for Competency Requirements of Reference Material Producers for Water Analysis |
I.S. EN ISO 17034:2016 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF REFERENCE MATERIAL PRODUCERS (ISO 17034:2016) |
14/30272865 DC : 0 | BS ISO 13547-1 - COPPER, LEAD, ZINC AND NICKEL SULFIDE CONCENTRATES - DETERMINATION OF ARSENIC - PART 1: IRON HYDROXIDE CONCENTRATION AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC METHOD |
05/30116640 DC : DRAFT APR 2005 | BS ISO 13291 - ZINC SULFIDE CONCENTRATES - DETERMINATION OF ZINC CONTENT - SOLVENT EXTRACTION AND EDTA TITRIMETRIC METHOD |
BS ISO 17315:2014 | Petroleum products and other liquids. Ethanol. Determination of total acidity by potentiometric titration |
13/30285144 DC : 0 | BS ISO 3679 - DETERMINATION OF FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD |
BS ISO 12156-1:1997 | Diesel fuel. Assessment of lubricity using the high-frequency reciprocating rig (HFRR) Test method |
05/30116637 DC : DRAFT APR 2005 | BS ISO 10469 - COPPER SULFIDE CONCENTRATES - DETERMINATION OF COPPER CONTENT - ELECTROGRAVIMETRIC METHOD |
BS ISO 10378:2016 | Copper, lead and zinc sulfide concentrates. Determination of gold and silver. Fire assay gravimetric and flame atomic absorption spectrometric method |
PD ISO/TR 10017:2003 | Guidance on statistical techniques for ISO 9001:2000 |
BS 2000-170(2013) : 2013 | DETERMINATION OF FLASH POINT - ABEL CLOSED-CUP METHOD (ISO 13736:2013) |
BS 2000-36(2002) : 2002 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - DETERMINATION OF FLASH AND FIRE POINTS - CLEVELAND OPEN CUP METHOD |
UNI CEI 70099 : 2008 | INTERNATIONAL VOCABULARY OF METROLOGY - BASIC AND GENERAL CONCEPTS AND ASSOCIATED TERMS (VIM) |
UNI EN 3976 : 2008 | AEROSPACE SERIES - TITANIUM AND TITANIUM ALLOYS - TEST METHOD - CHEMICAL ANALYSIS FOR THE DETERMINATION OF HYDROGEN CONTENT |
I.S. EN ISO 15351:2010 | STEEL AND IRON - DETERMINATION OF NITROGEN CONTENT - THERMAL CONDUCTIMETRIC METHOD AFTER FUSION IN A CURRENT OF INERT GAS (ROUTINE METHOD) |
NF EN ISO 15194 : 2009 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - REQUIREMENTS FOR CERTIFIED REFERENCE MATERIALS AND THE CONTENT OF SUPPORTING DOCUMENTATION |
CEI UNI EN ISO 17034 : 1ED 2018 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF REFERENCE MATERIAL PRODUCERS |
ISO 22682:2017 | Iron ores — Determination of trace elements — Plasma spectrometric method |
ISO 29301:2017 | Microbeam analysis — Analytical electron microscopy — Methods for calibrating image magnification by using reference materials with periodic structures |
IWA 13:2014 | Multiple resource evaluation guideline |
I.S. EN ISO 2592:2017 | PETROLEUM AND RELATED PRODUCTS - DETERMINATION OF FLASH AND FIRE POINTS - CLEVELAND OPEN CUP METHOD (ISO 2592:2017) |
BS ISO 17034 : 2016 | GENERAL REQUIREMENTS FOR THE COMPETENCE OF REFERENCE MATERIAL PRODUCERS |
ISO/TS 21749:2005 | Measurement uncertainty for metrological applications — Repeated measurements and nested experiments |
S.R. ISO/TR 10017:2003 | GUIDANCE ON STATISTICAL TECHNIQUES FOR ISO 9001:2000 |
ISO 2597-2:2015 | Iron ores Determination of total iron content Part 2: Titrimetric methods after titanium(III) chloride reduction |
ASTM E 2296 : 2003 : R2013 | Standard Practice for Silver Corrections in Metal Bearing Ores, Concentrates, and Related Metallurgical Materials by Fire Assay Slag Recycling and Cupel Proof Gravimetry |
ASTM D 6362 : 1998 | Standard Practice for Certificates of Reference Materials for Water Analysis |
ASTM D 6808 : 2002 | Standard Practice for Competency Requirements of Reference Material Producers for Water Analysis |
ASTM D 6596 : 2000 : R2011 | Standard Practice for Ampulization and Storage of Gasoline and Related Hydrocarbon Materials |
ASTM D 7345 : 2017 : REDLINE | Standard Test Method for Distillation of Petroleum Products and Liquid Fuels at Atmospheric Pressure (Micro Distillation Method) |
ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories |
ISO 11536:2015 | Iron ores Determination of loss on ignition Gravimetric method |
ISO 13547-1:2014 | Copper, lead, zinc and nickel sulfide concentrates Determination of arsenic Part 1: Iron hydroxide concentration and inductively coupled plasma atomic emission spectrometric method |
ISO 14595:2014 | Microbeam analysis — Electron probe microanalysis — Guidelines for the specification of certified reference materials (CRMs) |
ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
I.S. EN 15842:2010 | FOODSTUFFS - DETECTION OF FOOD ALLERGENS - GENERAL CONSIDERATIONS AND VALIDATION OF METHODS |
ISO/TS 16195:2013 | Nanotechnologies Guidance for developing representative test materials consisting of nano-objects in dry powder form |
DIN EN ISO 17511:2003-11 | In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials (ISO 17511:2003) |
ISO 10203:2017 | Iron ores Determination of calcium Flame atomic absorption spectrometric method |
ISO 16042:2007 | Iron ores Guidelines for the use of certified reference materials (CRMs) |
ISO/TR 18230:2015 | Iron ores Determination of loss on ignition Non-oxidised ores |
DIN EN ISO 13736:2013-08 | Determination of flash point - Abel closed-cup method (ISO 13736:2013) |
DIN EN ISO 12677:2013-02 | Chemical analysis of refractory products by X-ray fluorescence (XRF) - Fused cast-bead method (ISO 12677:2011) |
ISO 3679:2015 | Determination of flash no-flash and flash point — Rapid equilibrium closed cup method |
BS EN ISO 13736:2008 | Determination of flash point. Abel closed-cup method |
ISO 14111:1997 | Natural gas — Guidelines to traceability in analysis |
BS EN ISO 6974-2:2012 | Natural gas. Determination of composition and associated uncertainty by gas chromatography Uncertainty calculations |
BS EN ISO 2719:2002 | Determination of flash point. Pensky-Martens closed cup method |
BS EN ISO 3679:2015 | Determination of flash no-flash and flash point. Rapid equilibrium closed cup method |
UNE-EN ISO 3679:2015 | Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015) |
BS EN ISO 17511:2003 | In vitro diagnostic medical devices. Measurement of quantities in biological samples. Metrological traceability of values assigned to calibrators and control materials |
UNE-EN ISO 10993-12:2013 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
UNE-EN ISO 10723:2013 | Natural gas - Performance evaluation for analytical systems (ISO 10723:2012) |
ISO 12677:2011 | Chemical analysis of refractory products by X-ray fluorescence (XRF) Fused cast-bead method |
ISO 10723:2012 | Natural gas — Performance evaluation for analytical systems |
ISO 15351:1999 | Steel and iron — Determination of nitrogen content — Thermal conductimetric method after fusion in a current of inert gas (Routine method) |
ISO 6974-2:2012 | Natural gas — Determination of composition and associated uncertainty by gas chromatography — Part 2: Uncertainty calculations |
ISO 14189:2013 | Water quality — Enumeration of Clostridium perfringens — Method using membrane filtration |
UNE-EN ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2017) |
BS EN ISO 6974-1:2012 | Natural gas. Determination of composition and associated uncertainty by gas chromatography General guidelines and calculation of composition |
ISO 3680:2004 | Determination of flash/no flash Rapid equilibrium closed cup method |
BS EN ISO 10723:2012 | Natural gas. Performance evaluation for analytical systems |
ISO 13736:2013 | Determination of flash point Abel closed-cup method |
UNE-EN ISO 2719:2017 | Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016) |
ISO 17034:2016 | General requirements for the competence of reference material producers |
ISO 16140-1:2016 | Microbiology of the food chain — Method validation — Part 1: Vocabulary |
ISO 12179:2000 | Geometrical Product Specifications (GPS) Surface texture: Profile method Calibration of contact (stylus) instruments |
ISO 2719:2016 | Determination of flash point — Pensky-Martens closed cup method |
DIN EN ISO/IEC 17043:2010-05 | Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010) |
EN ISO 12677:2011 | Chemical analysis of refractory products by X-ray fluorescence (XRF) - Fused cast-bead method (ISO 12677:2011) |
I.S. EN ISO 12179:2000 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SURFACE TEXTURE: PROFILE METHOD - CALIBRATION OF CONTACT (STYLUS) INSTRUMENTS |
EN ISO 3679:2015 | Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015) |
EN ISO 14111:1999 | Natural gas - Guidelines to traceability in analysis (ISO 14111:1997) |
EN ISO 10723:2012 | Natural gas - Performance evaluation for analytical systems (ISO 10723:2012) |
EN ISO 17034:2016 | General requirements for the competence of reference material producers (ISO 17034:2016) |
EN ISO/IEC 17043:2010 | Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010) |
EN ISO 10993-8 : 2000 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 8: SELECTION AND QUALIFICATION OF REFERENCE MATERIALS FOR BIOLOGICAL TESTS |
EN 15842:2010 | Foodstuffs - Detection of food allergens - General considerations and validation of methods |
EN 3976:2006 | Aerospace series - Titanium and titanium alloys - Test method - Chemical analysis for the determination of hydrogen content |
EN ISO 15194:2009 | In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for certified reference materials and the content of supporting documentation (ISO 15194:2009) |
EN 16339:2013 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
EN ISO 3680:2004 | Determination of flash/no flash - Rapid equilibrium closed cup method (ISO 3680:2004) |
EN ISO 1523:2002 | Determination of flash point - Closed cup equilibrium method (ISO 1523:2002) |
EN ISO 16664:2017 | Gas analysis - Handling of calibration gases and gas mixtures - Guidelines (ISO 16664:2017) |
EN ISO 14189:2016 | Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration (ISO 14189:2013) |
04/30105010 DC : DRAFT JUL 2004 | ISO 12156-1 - DIESEL FUEL - ASSESSMENT OF LUBRICITY USING THE HIGH-FREQUENCY RECIPROCATING RIG (HFRR) - PART 1: TEST METHOD |
BS ISO 13291:2006 | Zinc sulfide concentrates. Determination of zinc. Solvent extraction and EDTA titrimetric method |
BS EN ISO 17034:2016 | General requirements for the competence of reference material producers |
PD ISO/TR 18230:2015 | Iron ores. Determination of loss on ignition. Non-oxidised ores |
14/30301977 DC : 0 | BS ISO 10204 - IRON ORES - DETERMINATION OF MAGNESIUM - FLAME ATOMIC ABSORPTION SPECTROMETRIC METHOD |
16/30336081 DC : 0 | BS EN ISO 16664 - GAS ANALYSIS - HANDLING OF CALIBRATION GASES AND GAS MIXTURES - GUIDELINES |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
PD ISO/TS 20460:2015 | Paper and board. Automated on-line testing. Metrological comparability between standardized measurements and output of on-line gauges |
BS ISO 14595:2014 | Microbeam analysis. Electron probe microanalysis. Guidelines for the specification of certified reference materials (CRMs) |
16/30320652 DC : 0 | BS ISO 20998-3 - MEASUREMENT AND CHARACTERIZATION OF PARTICLES BY ACOUSTIC METHODS - PART 3: GUIDELINES FOR NON-LINEAR THEORY |
ISO 4689-2:2017 | Iron ores Determination of sulfur content Part 2: Combustion/titration method |
12/30242232 DC : 0 | BS ISO 20998-2 - MEASUREMENT AND CHARACTERIZATION OF PARTICLES BY ACOUSTIC METHODS - PART 2: GUIDELINES FOR LINEAR THEORY |
BS 2000-523(2004) : 2004 | METHODS OF TEST FOR PETROLEUM AND ITS PRODUCTS - BS 2000-523: DETERMINATION OF FLASH POINT - RAPID EQUILIBRIUM CLOSED CUP METHOD |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
BS ISO 29301:2017 | Microbeam analysis. Analytical electron microscopy. Methods for calibrating image magnification by using reference materials with periodic structures |
ISO 14606:2015 | Surface chemical analysis — Sputter depth profiling — Optimization using layered systems as reference materials |
ISO 13312:2017 | Iron ores Determination of potassium Flame atomic absorption spectrometric method |
UNI EN 16339 : 2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
DD ISO/TS 21749:2005 | Measurement and uncertainty for metrological applications. Repeated measurements and nested experiments |
OIML R 146-1 : 2016 | PROTEIN MEASURING INSTRUMENTS FOR CEREAL GRAIN AND OILSEEDS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
CEI UNI EN ISO/IEC 17043 : 2011 | CONFORMITY ASSESSMENT - GENERAL REQUIREMENTS FOR PROFICIENCY TESTING |
BS ISO 10203:2017 | Iron ores. Determination of calcium. Flame atomic absorption spectrometric method |
BS ISO 13313:2017 | Iron ores. Determination of sodium. Flame atomic absorption spectrometric method |
PD ISO GUIDE 33:2015 | Reference materials. Good practice in using reference materials |
BS ISO 14189 : 2013 | WATER QUALITY - ENUMERATION OF CLOSTRIDIUM PERFRINGENS - METHOD USING MEMBRANE FILTRATION |
PD ISO/TR 18336:2016 | Guidelines for good XRF laboratory practice for the iron ore industry |
CSA ISO/TR 10017:2003 | GUIDANCE ON STATISTICAL TECHNIQUES FOR ISO 9001:2000 |
ASTM D 8174 : 2018 | Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester |
EN ISO 10993-12:2012 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
97/402277 DC : DRAFT APR 1997 | PREN 45001 - GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES |
00/565675 DC : DRAFT DEC 2000 | BS EN ISO 17511 - IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - METROLOGICAL TRACEABILITY OF VALUES ASSIGNED TO CALIBRATORS AND CONTROL MATERIALS |
PD ISO GUIDE 31:2015 | Reference materials. Contents of certificates, labels and accompanying documentation |
UNI EN ISO 15194 : 2009 | IN VITRO DIAGNOSTIC MEDICAL DEVICES - MEASUREMENT OF QUANTITIES IN SAMPLES OF BIOLOGICAL ORIGIN - REQUIREMENTS FOR CERTIFIED REFERENCE MATERIALS AND THE CONTENT OF SUPPORTING DOCUMENTATION |
BS ISO 4689-2:2017 | Iron ores. Determination of sulfur content Combustion/titration method |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO Guide 33:2015 | Reference materials — Good practice in using reference materials |
ANSI/AAMI/ISO 10993-12:2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS |
ISO 13528:2015 | Statistical methods for use in proficiency testing by interlaboratory comparison |
ISO 20998-2:2013 | Measurement and characterization of particles by acoustic methods — Part 2: Guidelines for linear theory |
ISO 15634:2015 | Iron ores — Determination of chromium content — Flame atomic absorption spectrometric method |
PREN 17155 : DRAFT 2017 | LIQUID PETROLEUM PRODUCTS - DETERMINATION OF INDICATED CETANE NUMBER (ICN) OF MIDDLE DISTILLATE FUELS - PRIMARY REFERENCE FUELS CALIBRATION METHOD USING A CONSTANT VOLUME COMBUSTION CHAMBER |
17/30360226 DC : 0 | BS EN 17155 - LIQUID PETROLEUM PRODUCTS - DETERMINATION OF INDICATED CETANE NUMBER (ICN) OF MIDDLE DISTILLATE FUELS - PRIMARY REFERENCE FUELS CALIBRATION METHOD USING A CONSTANT VOLUME COMBUSTION CHAMBER |
BS ISO 15633:2017 | Iron ores. Determination of nickel. Flame atomic absorption spectrometric method |
ASTM D 6808 : 2002 : R2007 | Standard Practice for Competency Requirements of Reference Material Producers for Water Analysis |
ASTM E 2294 : 2003 : R2013 | Standard Practice for Proof Silver Corrections in Metal Bearing Ores, Concentrates, and Related Materials by Fire Assay Gravimetry |
ISO 17315:2014 | Petroleum products and other liquids — Ethanol — Determination of total acidity by potentiometric titration |
ISO 15247:2015 | Zinc sulfide concentrates Determination of silver content Acid dissolution and flame atomic absorption spectrometric method |
ISO/TR 10017:2003 | Guidance on statistical techniques for ISO 9001:2000 |
I.S. EN ISO 16664:2017 | GAS ANALYSIS - HANDLING OF CALIBRATION GASES AND GAS MIXTURES - GUIDELINES (ISO 16664:2017) |
BS EN ISO 1523:2002 | Method of test for petroleum and its products. Determination of flash point. Closed cup equilibrium method |
ISO/TS 13530:2009 | Water quality — Guidance on analytical quality control for chemical and physicochemical water analysis |
ISO 148-3:2016 | Metallic materials — Charpy pendulum impact test — Part 3: Preparation and characterization of Charpy V-notch test pieces for indirect verification of pendulum impact machines |
BS EN 3976:2006 | Aerospace series. Titanium and titanium alloys. Test method. Chemical analysis for the determination of hydrogen content |
BS EN ISO 12179:2001 | Geometrical product specifications (GPS). Surface texture. Profile method. Calibration of contact (stylus) instruments |
ISO 16664:2017 | Gas analysis — Handling of calibration gases and gas mixtures — Guidelines |
DIN EN ISO 3680:2004-07 | DETERMINATION OF FLASH/NO FLASH - RAPID EQUILIBRIUM CLOSED CUP METHOD |
EN 10315:2006 | Routine method for analysis of high alloy steel by X-ray Fluorescence Spectrometry (XRF) by using a near by technique |
EN 12697-38:2004 | Bituminous mixtures - Test methods for hot mix asphalt - Part 38: Common equipment and calibration |
CEI UNI EN ISO/IEC 17043:2024-05 | Conformity assessment General requirements for the competence of proficiency testing providers |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
AS ISO 19976.2:2020 | Copper, lead and zinc sulfide concentrates - Determination of cadmium Acid digestion and inductively coupled plasma atomic emission spectrometric method |
ISO 17034:2016 | General requirements for the competence of reference material producers |
ISO 11843-1:1997 | Capability of detection — Part 1: Terms and definitions |
ISO 13528:2015 | Statistical methods for use in proficiency testing by interlaboratory comparison |
ISO 15189:2012 | Medical laboratories — Requirements for quality and competence |
ISO/TR 16476:2016 | Reference materials — Establishing and expressing metrological traceability of quantity values assigned to reference materials |
ISO/TR 79:2015 | Reference materials - Examples of reference materials for qualitative properties |
ISO 16269-4:2010 | Statistical interpretation of data Part 4: Detection and treatment of outliers |
ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method |
ISO Guide 33:2015 | Reference materials — Good practice in using reference materials |
AS ISO 19976.1:2020 | Copper, lead and zinc sulfide concentrates - Determination of cadmium Flame atomic absorption spectrometric method |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO 3534-2:2006 | Statistics — Vocabulary and symbols — Part 2: Applied statistics |
ISO Guide 30:2015 | Reference materials — Selected terms and definitions |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 3534-3:2013 | Statistics — Vocabulary and symbols — Part 3: Design of experiments |
ISO 6865:2000 | Animal feeding stuffs — Determination of crude fibre content — Method with intermediate filtration |
ISO 6142-1:2015 | Gas analysis Preparation of calibration gas mixtures Part 1: Gravimetric method for Class I mixtures |
ISO Guide 31:2015 | Reference materials — Contents of certificates, labels and accompanying documentation |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.