ISO 10295-2:2009
Current
The latest, up-to-date edition.
Fire tests for building elements and components Fire testing of service installations Part 2: Linear joint (gap) seals
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
19-01-2009
ISO 10295-2:2009 specifies the heating conditions, methods of test and criteria for the evaluation of the ability of a linear joint seal to maintain the fire integrity and thermal insulation of a fire-separating element at the joint being sealed. The purpose of the tests is to assess the integrity and insulation performance of the linear joint seals, including the effects of induced movement in those cases where the joint is designed to accommodate movement and has a width greater than 20 mm.
It is not the intention of this part of ISO 10295-2:2009 to provide quantitative information on the rate of leakage of smoke and/or gases, or on the transmission or generation of fumes, although such phenomena can be recorded in describing the general behaviour of specimens during the test. It is not the intention of this part of ISO 10295-2:2009 to evaluate joint seals where special test procedures already exist, e.g. doors, partitions, penetrations, pipes, ducts and cables.
DevelopmentNote |
Supersedes ISO/DIS 10295-2. (01/2009)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
BS ISO 10295-2:2009 | Identical |
PD ISO/TR 10295-3:2012 | Fire tests for building elements and components. Fire testing of service installations Single component penetration seals. Guidance on the construction and use of test configurations and simulated services to characterise sealing materials |
PD 7974-3:2011 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin |
ASTM E 3038 : 2016 | Standard Practice for Assessing and Qualifying Candidates as Inspectors of Firestop Systems and Fire-Resistive Joint Systems |
ASTM E 2837 : 2013 : R2017 | Standard Test Method for Determining the Fire Resistance of Continuity Head-of-Wall Joint Systems Installed Between Rated Wall Assemblies and Nonrated Horizontal Assemblies |
ASTM E 2837 : 2013 | Standard Test Method for Determining the Fire Resistance of Continuity Head-of-Wall Joint Systems Installed Between Rated Wall Assemblies and Nonrated Horizontal Assemblies |
ISO/TR 10295-3:2012 | Fire tests for building elements and components Fire testing of service installations Part 3: Single component penetration seals Guidance on the construction and use of test configurations and simulated services to characterise sealing materials |
ISO 10241:1992 | International terminology standards Preparation and layout |
ISO 690:2010 | Information and documentation Guidelines for bibliographic references and citations to information resources |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 3008:2007 | Fire-resistance tests Door and shutter assemblies |
ISO 3009:2003 | Fire-resistance tests — Elements of building construction — Glazed elements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.