IEEE DRAFT C63.19 : 2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
METHODS OF MEASUREMENT OF COMPATIBILITY BETWEEN WIRELESS COMMUNICATIONS DEVICES AND HEARING AIDS
Hardcopy , PDF
08-06-2007
English
01-01-2005
1 OVERVIEW
1.1 Scope
1.2 Purpose
1.3 Organization and Use of the Document
2 REFERENCES
3 DEFINITIONS, ACRONYMS AND ABBREVIATIONS
3.1 Definitions
3.2 Acronyms and Abbreviations
4 WIRELESS DEVICE, RF EMISSIONS TEST
4.1 Measured RF interference level
4.2 Test Equipment and Facilities
4.3 Test Setup and Validation
4.4 Near-Field Test Procedure
5 HEARING AID RF NEAR-FIELD IMMUNITY TEST
5.1 Test Facilities and Equipment
5.2 Test Setup and Validation
5.3 RF Immunity Test Procedure - Primary
5.4 RF Immunity Test Procedure - Alternate
6 WIRELESS DEVICE T-COIL SIGNAL TEST
6.1 Test Facilities and Equipment
6.2 Test Configurations and Setup
6.3 Test Procedure for T-Coil Signal
6.4 Broadband Test Procedure - Alternate
7 PERFORMANCE
7.1 Articulation weighting factor (AWF)
7.2 Audio Coupling Mode
7.3 T-Coil Coupling Mode
7.4 Accessories and Options
7.5 Product Line Compliance
8 CALIBRATION AND MEASUREMENT UNCERTAINTY
8.1 General
8.2 Ambient Conditions
8.3 Specific Calibration Requirements
8.4 Measurement Uncertainty
9 TEST REPORT
9.1 Test Plan
9.2 Applicable Standards
9.3 Equipment Unit Tested
9.4 Test Configuration
9.5 List of Test Equipment
9.6 Units of Measurement
9.7 Location of Test Site
9.8 Measurement Procedures
9.9 Reporting Measurement Data
9.10 General and Special Conditions
9.11 Summary of Results
9.12 Required Signatures
9.13 Test Report Annexes
9.14 Test Report Disposition
10 BIBLIOGRAPHY
ANNEX A. DEFINITION OF REFERENCE AXES - (NORMATIVE)
A.1 Axes definition for hearing aid RF immunity tests
A.2 WD RF emission measurements reference and plane
A.3 T-Coil measurement points and reference plane
ANNEX B. TEST FREQUENCIES - (NORMATIVE)
B.1 Acoustic test frequencies
B.2 Test channels and frequencies
ANNEX C. EQUIPMENT AND SETUP CALIBRATION - (NORMATIVE)
C.1 Test enclosures
C.2 Audio input source
C.3 Calibration of RF electric and magnetic field probes
C.4 Calibration of dipoles
C.5 Calibration of hearing aid probe coil
C.6 Selection and calibration of acoustic transmission
line (Informative)
C.7 Microphone subsystem requirements
ANNEX D. TEST EQUIPMENT SPECIFICATIONS - (NORMATIVE)
D.1 Acoustic damper
D.2 Audio frequency analyzer or wave analyzer
D.3 Audio signal generator
D.4 Bandpass filter
D.5 Dipole, resonant
D.6 Directional coupler
D.7 Frequency generator
D.8 Hearing aid probe coil
D.9 Helmholtz calibration coils
D.10 Probe, near-field, E-field
D.11 Probe, near-field, H-field
D.12 RF cables
D.13 RF Communications test set
D.14 RF power amplifier
D.15 RF Signal generator
D.16 RF wattmeter
D.17 T-Coil integrator
D.18 TEM cell
D.19 Telephone Magnetic Field Simulator (TMFS)
D.20 True RMS voltmeter
ANNEX E. SAMPLE MEASUREMENT UNCERTAINTY ESTIMATES - (INFORMATIVE)
E.1 WD near-field emissions measurement uncertainty
E.2 Hearing aid near-field immunity measurement uncertainty
E.3 WD audio band measurement uncertainty
E.4 Sample estimation
ANNEX F. USE OF HELMHOLTZ COILS FOR CALIBRATION - (INFORMATIVE)
F.1 Introduction
F.2 Axial field-strength accuracy
F.3 Radial field-strength
F.4 Summary
F.5 References
ANNEX G. RF ENVELOPE COMPARISON FOR US WD SYSTEMS - (INFORMATIVE)
G.1 Introduction
G.2 AMPS
G.3 NADC
G.4 GSM and PCS
G.5 CDMA
G.6 IDEN[TM]
ANNEX H. EXPLANATION OF RATIONALE USED IN THIS STANDARD -
(INFORMATIVE)
ANNEX I. MEASUREMENT OF PEAK POWER ACROSS MULTIPLE AIRLINK
TECHNOLOGIES (INFORMATIVE)
I.1 Introduction
I.2 RF power measurement terminology
I.3 Statistical RF power measurement
I.4 Peak envelope power vs. airlink technology
I.5 Conclusion
ANNEX J. SAMPLE HAC APPLICATION FORMS (INFORMATIVE)
J.1 E-Field technical report
J.2 H-Field technical report
REVISION HISTORY
Pertains to both wireless communications devices (WDs) and hearing aids. It sets forth uniform methods of measurement and parametric requirements for the electromagnetic and operational compatibility and accessibility of hearing aids used with wireless communications devices, including cordless, cellular, Personal Communications Service (PCS) phones and Voice over Internet Protocol (VoIP) devices, operating in the range of 800 MHz to 3 GHz.
DocumentType |
Draft
|
Pages |
152
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
TIA/EIA 136 SET : H2011 | TDMA THIRD GENERATION WIRELESS |
ANSI/ASA S3.7 : 2016 | METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES |
IEEE 661 : 1979 | METHOD FOR DETERMINING OBJECTIVE LOUDNESS RATINGS OF TELEPHONE CONNECTIONS |
IEC 60118-7:2005 | Electroacoustics - Hearing aids - Part 7: Measurement of the performance characteristics of hearing aids for production, supply and delivery quality assurance purposes |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
IEEE 299-2006 | IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures |
IEC 60318-3:2014 | Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry |
IEC 60118-1:1995+AMD1:1998 CSV | Hearing aids - Part 1: Hearing aids with induction pick-up coil input |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
ISO 266:1997 | Acoustics — Preferred frequencies |
IEC 60118-13:2016 | Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEEE 1309-2013 REDLINE | IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEC 60126:1973 | IEC reference coupler for the measurement of hearing aids using earphones coupled to the ear by means of ear inserts |
CISPR TR 16-4-3:2004+AMD1:2006 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products |
CFR 47(PTS40-69) : OCT 2017 | TELECOMMUNICATIONS - FEDERAL COMMUNICATIONS COMMISSION |
TIA/EIA/IS 2000 SERIES : C2002 | CDMA 2000 SERIES |
IEC 61094-3:2016 | Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
CFR 47(PTS0-19) : OCT 2017 | TELECOMMUNICATION - FEDERAL COMMUNICATIONS COMMISSION |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
IEEE C95.3-2002 | IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz |
IEC 60318-2:1998 | Electroacoustics - Simulators of human head and ear - Part 2: An interim acoustic coupler for the calibration of audiometric earphones in the extended high-frequency range |
IEEE/ANSI C63.14-2014 REDLINE | American National Standard Dictionary of Electromagnetic Compatibility (EMC) including Electromagnetic Environmental Effects (E3) |
IEEE C63.2-2009 | American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEEE C95.1-2005 | IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
CFR 47(PTS20-39) : OCT 2017 | TELECOMMUNICATIONS - FEDERAL COMMUNICATIONS COMMISSION |
TIA/EIA TSB 31 : D2011 ADD 4 2016 | TELECOMMUNICATIONS TELEPHONE TERMINAL EQUIPMENT RATIONALE AND MEASUREMENT GUIDELINES FOR U.S. NETWORK PROTECTION |
CISPR TR 16-4-4:2007 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services |
ANSI/ASA S3.22:2014 | SPECIFICATION OF HEARING AID CHARACTERISTICS |
IEC 60118-4:2014+AMD1:2017 CSV | Electroacoustics - Hearing aids - Part 4: Induction-loop systems for hearing aid purposes - System performance requirements |
IEC 60118-0:2015 | Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids |
IEC 60318-1:2009 | Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
CFR 47(PTS80-END) : OCT 2017 | TELECOMMUNICATION - FEDERAL COMMUNICATIONS COMMISSION |
IEEE 269-2010 REDLINE | IEEE Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone Sets, Handsets, and Headsets |
TIA/EIA/IS 91 : 1999 | BASE STATION - MOBILE STATION COMPATIBILITY SPECIFICATION FOR 800 MHZ CELLULAR, AUXILIARY, AND RESIDENTIAL SERVICES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.