IEEE DRAFT C57.16 : D10 AUG 95

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

TERMINOLOGY AND TEST CODE FOR DRY-TYPE AIR-CORE SERIES CONNECTED REACTORS

Superseded date

13-06-1997

Superseded by

IEEE C57.16-2011

Published date

12-01-2013

Sorry this product is not available in your region.

1 Scope
2 Terminology
   2.1 Types of Dry Type Air Core Series Reactors
   2.2 Series Reactor Applications
   2.3 Voltage Definitions
   2.4 Rating of a Series Reactor
   2.5 Insulation
   2.6 Losses, Impedance and System Frequency
3 References
4 General Requirements
   4.1 Service Conditions
   4.2 Operation at Altitudes in Excess of 3300 Feet
5 Rating
   5.1 Basis of Rating
   5.2 Reactance Rating
   5.3 Voltage Rating
   5.4 Continuous Current Rating
   5.5 Short-Circuit Current Rating
6 Tests
   6.1 Where Tests Are To Be Made
   6.2 Types of Tests
7 Losses and Impedance
   7.1 Losses
   7.2 Impedance
   7.3 Impedance and Losses Test
8 Temperature Rise
   8.1 Life of Insulating Materials
   8.2 Limits of Temperature Rise
   8.3 Temperature Rise Tests
9 Insulation Levels and Dielectric Tests
   9.1 Impulse Insulation Levels
   9.2 Dielectric Test Levels
   9.3 Dielectric Tests
10 Short-Circuits
   10.1 Short-Circuit Capability
   10.2 Mechanical Limit of Current Limiting Reactors for
        Short-circuit Conditions
   10.3 Thermal Limit of Current Limiting Reactors for
        Short-circuit Conditions
   10.4 Mechanical Short-circuit Tests
11 Test Code
   11.1 General
   11.2 Resistance Measurements
   11.3 Dielectric Tests
   11.4 Losses and Impedance
   11.5 Temperature Rise Tests
   11.6 Short-circuit Test
   11.7 Short-time Current
   11.8 Audible Sound Level Test
12 Construction
   12.1 Nameplates
   12.2 Insulator Units
   12.3 tap (In a Reactor)
TABLES
Table 1 Dielectric Strength Correction Factors for
          Altitudes Greater Than 3300 Feet (1000 Meters)
Table 2 Maximum Allowable 24h Average Temperature of
          Cooling Air to Permit Dry-type Air-Core Series
          Reactors to Carry Rated Current
Table 3 Routine Design and Other Tests for Dry-Type
          Series Reactors
Table 4 Limits of Temperature Rise for Continuously
          Rated Dry-Type Air-Core Series Reactors
Table 5 Insulation Test Levels for Dry-Type Air-Core
          Series Reactors
Table 6 Radio Influence Voltage
Table 7 Value of K for Use in Equation 10.2.2
Table 8 Limiting Temperature for Rated Short-Time
          Current
Figures
Fig.1 Connections for the Drop-of-Potential Method
          of Resistance Measurement
Fig.2 Turn-to-Turn Test Circuit and Sample
          Oscillogrammes
Fig.3 Single-Phase Reactor Connections for Impedance
          -Loss and Impedance-Voltage Tests. Instrument
          Transformers to be Added When Necessary
Fig.4 Three-Phase Reactor Connections for Impedance
          -Loss and Impedance-Voltage Tests. Instrument
          Transformers to be Added When Necessary
Fig.5 Guideline for Bus Connection and Arrangement
          for Short-Circuit Testing
Fig.6 Microphone Locations for Audible Sound Tests
Fig. A1 Single Quadrant Plot of Flux Surrounding a
          Typical Reactor
Fig. A2 Installation Guidance Summary - Basic Rules
Fig. D1 Typical Configurations for a Series
          Compensation Capacitor with Discharge Current
          Limiting Reactor
ANNEX TO DIELECTRIC TESTS INCLUDING INFORMATION ON WAVE-
SHAPE CONTROL
Annex A: Construction and Installation of Dry-Type Air-
          Core Series Reactor
Annex B: Specific Requirements For Dry-Type Air-Core
          Filter Reactors
Annex C: Dry-Type Air-Core Shunt Capacitor Reactors
Annex D: Dry-Type Air-Core Discharge Current-Limiting
          Reactors For Series Capacitor Bank
          Applications

Refers to "series connected" dry-type air-core single-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady state conditions and/or limit fault current under short-circuit conditions. Dry-type air-core reactor covered by this standard are self-cooled by natural air convection.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy

IEEE C37.12-2008 SPECIFICATION GUIDE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS BASED ON A SYMMETRICAL CURRENT BASIS
ANSI S1.4 : 1983 SPECIFICATION FOR SOUND LEVEL METERS
ANSI S1.11 : 2014 SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS
IEEE 344-2013 IEEE Standard for Seismic Qualification of Equipment for Nuclear Power Generating Stations
IEC 60722:1982 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
IEEE C37.06-2009 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
IEEE C57.21 : 2008 REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR SHUNT REACTORS RATED OVER 500 KVA
IEEE 18-2012 IEEE Standard for Shunt Power Capacitors