1 Overview
2 Normative references
3 Definitions
4 Overview
5 Loading equations
6 Loading based on life expectancy
Annex A (informative) - Bibliography
Annex B (informative) - Computer programs
Annex C (informative) - Example calculations

This guide covers general recommendations for the loading of dry-type distribution and power transformers installed in ventilated, non-ventilated, and sealed type enclosures.

Committee
Transformers
DevelopmentNote
Supersedes IEEE DRAFT C57.96. (11/2004)
DocumentType
Standard
ISBN
978-0-7381-8831-7
Pages
46
PublisherName
Institute of Electrical & Electronics Engineers
Status
Current
Supersedes

IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
IEEE 1653.3-2012 IEEE Guide for Rail Transit Traction Power Systems Modeling
IEEE C57.32-2015 IEEE Standard for Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
BS EN 62040-3:2011 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
IEEE DRAFT C57.12.91 : D3 2000 DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
IEEE 1566-2015 IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger
TM 5-811-1 : V19950228 ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION
CSA C802.5 : 2016 GUIDELINE FOR EVALUATING THE EFFICIENCY OF DRY-TYPE TRANSFORMERS UNDER NON-LINEAR LOADING
I.S. EN 62040-3:2011 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
NEMA ST 20:2014 Dry Type Transformers for General Applications
NEMA TR1 : 2013 TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS
CEI EN 62040-3 : 2015 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
UFC 3-550-01 : CHANGE 1 UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION
14/30297921 DC : 0 BS EN 62040-5-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS FOR D.C. UPS
IEEE 638-2013 IEEE Standard for Qualification of Class 1E Transformers for Nuclear Power Generating Stations
IEEE DRAFT C57.18.10 : D12 APR 97 DRAFT PRACTICES AND REQUIREMENTS FOR SEMICONDUCTOR POWER RECTIFIER TRANSFORMER
EN 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
API 540 : 1999 : R2006 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
IEEE 1818-2017 IEEE Guide for the Design of Low-Voltage Auxiliary Systems for Electric Power Substations
IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
CSA C802.4 : 2013 GUIDE FOR KVA SIZING OF DRY-TYPE TRANSFORMERS, 1.2 KV CLASS, SINGLE-PHASE AND THREE-PHASE
IEEE DRAFT C57.12.01 : D6 2005 GENERAL REQUIREMENTS FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS INCLUDING THOSE WITH SOLID-CAST AND/OR RESIN ENCAPSULATED WINDINGS
IEEE C57.159-2016 IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems
IEEE C57.12.59-2015 IEEE Guide for Dry-Type Transformer Through-Fault Current Duration
IEEE C37.121-2012 GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS
IEEE C57.12.52-2012 IEEE Standard for Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
API 540:1999 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
IEC 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEEE 1653.1-2016 IEEE Standard for Traction Power Rectifier Transformers for Substation Applications up to 1500 V DC Nominal Output
C9-17 Dry-type transformers
IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements
IEEE C57.94-2015 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type Distribution and Power Transformers
IEEE C57.12.01-2020 IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
IEEE C57.12.91-2020 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
IEEE C57.12.60-2020 IEEE Standard for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers
IEEE/IEC 60076-16-2018 IEC/IEEE International Standard - Power transformers - Part 16: Transformers for wind turbine applications

IEEE C57.12.59-2015 IEEE Guide for Dry-Type Transformer Through-Fault Current Duration
IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
IEEE C57.134-2013 IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers
IEEE C57.12.60-2009 REDLINE IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers
IEEE C57.12.01-2005 IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings
IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
IEEE C57.138-1998 IEEE Recommended Practice for Routine Impulse Test for Distribution Transformers
IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
IEEE C57.12.56-1986 IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Ventilated Dry-Type Power and Distribution Transformers
IEEE C57.110-2008 REDLINE IEEE Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.