Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE C57.12.56-1986

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Ventilated Dry-Type Power and Distribution Transformers

Available format(s)

PDF

Language(s)

English

Published date

03-10-1986

Superseded date

15-10-2021

$243.28
Including GST where applicable

1 Introduction
  1.1 Scope
  1.2 Purpose
  1.3 References
  1.4 Applicable Document in preparation
2 Basic Considerations
  2.1 General
  2.2 Intent
  2.3 Aging factors
  2.4 Data treatment
3 Test Procedures
  3.1 General
  3.2 Test Models
  3.3 Screening
  3.4 Test Cycles
  3.5 Temperature Aging
  3.6 Humidity Conditioning
  3.7 Dielectric Tests
4 Reporting
Annex A (informative)
Annex B (informative)

Determines temperature classification of ventilated dry-type power and distribution transformer insulation systems by test rather than chemical composition. For transformers listed in ANSI C57.12.50-1981, ANSI C57.12.51-1981 with highest voltages of over 600 V.

Committee
Transformers
DocumentType
Standard
Pages
20
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded

IEEE DRAFT C57.12.91 : D3 2000 DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
IEEE DRAFT 1147 : D8 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
IEEE C57.96-2013 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
IEEE 638-2013 IEEE Standard for Qualification of Class 1E Transformers for Nuclear Power Generating Stations
IEEE C57.12.60-2009 REDLINE IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers
IEEE DRAFT C57.12.01 : D6 2005 GENERAL REQUIREMENTS FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS INCLUDING THOSE WITH SOLID-CAST AND/OR RESIN ENCAPSULATED WINDINGS
IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
IEEE 1653.1-2016 IEEE Standard for Traction Power Rectifier Transformers for Substation Applications up to 1500 V DC Nominal Output
IEEE C57.96-1999 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
IEEE C57.12.01-2005 IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings
IEEE 638-1992 IEEE Standard for Qualification of Class 1E Transformers for Nuclear Power Generating Stations

IEEE C57.12.51-2008 REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS
IEEE 101A-1974 IEEE Simplified Method for Calculation of the Regression Line (Appendix to IEEE Guide for the Statistical Analysis of Thermal Life Test Data, IEEE Std 101-1972)
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
IEEE 101 : 1987 GUIDE FOR THE STATISTICAL ANALYSIS OF THERMAL LIFE TEST DATA
ASTM E 104 : 2002 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions
IEEE C57.12.50 : 1981 REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

$243.28
Including GST where applicable