IEEE C37.41-2008 REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices

Available format(s)

PDF

Superseded date

12-09-2016

Superseded by

IEEE C37.41-2016

Published date

13-03-2009

1. Overview
2. Normative references
3. Definitions
4. Normal (usual) and special (unusual) service
    conditions
5. Classifications, ratings, and characteristics
6. Required design (type) tests
7. Common test requirements for all design tests
8. Dielectric tests
9. Interrupting tests
10. Radio-influence tests
11. Temperature-rise tests
12. Time-current tests
13. Manual-operation, thermal-cycle, and bolt-torque
    tests
14. Liquid-tightness tests for current-limiting fuses and
    FEPs
15. Static-relief pressure tests for expulsion fuses that use
    expendable caps
16. Lightning surge impulse withstand test for fuse links
17. Withstand tests for fuses intended for motor circuit
    applications
18. Tests for expulsion fuses having cutout fuse supports
    utilizing polymeric insulators
Annex A (normative) - Test requirements for additional
        devices
Annex B (informative) - Recommended methods for determining
        the value of a sinusoidal current wave and a
        power-frequency recovery voltage
Annex C (informative) - Recommended method of determining
        the equivalent steady-state rms current for plotting
        time-current curves
Annex D (informative) - Simplified fault-current calculation -
        interrupting duty and rated short-time withstand
        current
Annex E (informative) - Transient recovery voltage (TRV)
        parameters
Annex F (normative) - Criteria for determining I[t] testing
        validity for current-limiting fuses
Annex G (informative) - Bibliography

Defines test requirements for high-voltage (above 1000 V) fuses and accessories for use on ac electrical distribution systems.

Committee
Switchgear
DevelopmentNote
Supersedes IEEE DRAFT C37.41. (04/2001) Supersedes IEEE C37.41E. (01/2011)
DocumentType
Standard
ISBN
978-0-7381-5844-0
Pages
123
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE C37.73-1998 IEEE Standard Requirements for Pad-Mounted Fused Switchgear
IEEE DRAFT C37.48 : D5 NOV 96 GUIDE FOR APPLICATION, OPERATION AND MAINTENANCE OF HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE DRAFT C37.48.1 : D13 2000 DRAFT GUIDE FOR THE OPERATION, CLASSIFICATION, APPLICATION AND COORDINATION OF CURRENT-LIMITING FUSES WITH RATED VOLTAGES 1-38 KV
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEEE C57.12.20-2011 REDLINE IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below
IEEE C37.48.1-2002 IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV
IEEE C37.42-2009 SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS
08/30184557 DC : DRAFT JUNE 2008 BS EN 62271-111 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 111: PAD-MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR ALTERNATING CURRENT SYSTEMS UP TO 38 KV
IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE C37.302-2015 IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC
IEEE DRAFT C37.108 : D6 98 DRAFT GUIDE FOR THE PROTECTION OF NETWORK TRANSFORMERS
CSA C310 : 2009 : R2014 DISTRIBUTION CLASS POLYMERIC CUTOUTS
IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
NEMA SG 2 : 1993 HIGH VOLTAGE FUSES
UFC 3-550-01 : CHANGE 1 UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION
18/30356222 DC : DRAFT MAR 2018 BS EN 60282-4 - ADDITIONAL TESTING REQUIREMENTS FOR HIGH-VOLTAGE EXPULSION FUSES UTILIZING POLYMERIC INSULATORS
ANSI C37.44 : 1981 AMERICAN NATIONAL STANDARD SPECIFICATIONS FOR DISTRIBUTION OIL CUTOUTS AND FUSE LINKS
IEEE C57.12.39-2017 IEEE Standard for Requirements for Distribution Transformer Tank Pressure Coordination
IEEE DRAFT C37.20.4 : 2001 DRAFT STANDARD FOR INDOOR AC SWITCHES RATED ABOVE 1KV THROUGH 38KV FOR USE IN METAL-ENCLOSED SWITCHGEAR
IEEE C37.47-2011 IEEE Standard Specifications for High-Voltage (>1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting Switches
IEEE C37.46-2010 IEEE Standard Specifications for High-Voltage (>1000 V) Expulsion and Current-Limiting Power Class Fuses and Fuse Disconnecting Switches
CSA C310 : 2009 DISTRIBUTION CLASS POLYMERIC CUTOUTS
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
PD IEC/TR 62655:2013 Tutorial and application guide for high-voltage fuses
IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
IEEE DRAFT 551 : D5 2005 CALCULATING AC SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
IEEE C37.74-2014 IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV
IEEE 495 : 2007 TESTING FAULTED CIRCUIT INDICATORS
IEEE C57.12.20-2011 TRANSFORMERS - STANDARD FOR OVERHEAD TYPE DISTRIBUTION TRANSFORMERS, 500 KVA AND SMALLER: HIGH VOLTAGE, 34500 VOLTS AND BELOW: LOW VOLTAGE, 7970/13800Y VOLTS AND BELOW
IEEE C37.42-2009 IEEE Standard Specifications for High-Voltage (> 1000 V) Expulsion-Type Distribution-Class Fuses, Fuse and Disconnecting Cutouts, Fuse Disconnecting Switches, and Fuse Links, and Accessories Used with These Devices
IEEE C37.43-2008 IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors
CSA C310 : 2009 : INC : UPD 2 : 2012 DISTRIBUTION CLASS POLYMERIC CUTOUTS
IEEE C37.46-2010 FOR HIGH VOLTAGE EXPULSION AND CURRENT-LIMITING TYPE POWER CLASS FUSES AND FUSE DISCONNECTING SWITCHES
IEC TR 62655:2013 Tutorial and application guide for high-voltage fuses
IEEE 1247 : 2005 INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V
IEEE 18-2012 IEEE Standard for Shunt Power Capacitors
IEEE 551 : 2006 CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
IEEE DRAFT C57.12.20 : D10C 2004 OVERHEAD TYPE DISTRIBUTION TRANSFORMERS, 500 KVA AND SMALLER: HIGH VOLTAGE, 34 500 VOLTS AND BELOW; LOW VOLTAGE, 7970/13 800Y VOLTS AND BELOW
IEEE C37.48.1-2011 IEEE Guide for the Application, Operation, and Coordination of High-Voltage (>1000 V) Current-Limiting Fuses

IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
IEEE 4-1995 IEEE Standard Techniques for High-Voltage Testing
IEEE C37.42-2009 IEEE Standard Specifications for High-Voltage (> 1000 V) Expulsion-Type Distribution-Class Fuses, Fuse and Disconnecting Cutouts, Fuse Disconnecting Switches, and Fuse Links, and Accessories Used with These Devices
IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
IEC 60549:2013 High-voltage fuses for the external protection of shunt capacitors
IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE C37.43-2008 IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors
ASTM G 154 : 2016 : REDLINE Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials
IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
IEEE 1247 : 2005 INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE C63.2-2009 American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications
NEMA CC1 : 2009(R2015) ELECTRIC POWER CONNECTORS FOR SUBSTATIONS
IEEE C37.20.3-2001 IEEE Standard for Metal-Enclosed Interrupter Switchgear
IEEE C37.45-2007 IEEE Standard Specifications for High Voltage Distribution Class Enclosed Single-Pole Air Switches with Rated Voltages from 1 through 8.3 kV
IEEE 18-2012 IEEE Standard for Shunt Power Capacitors
IEEE C37.48.1-2002 IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.