Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE 802.3AF : 2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS - AMENDMENT: DATA TERMINAL EQUIPMENT (DTE) POWER VIA MEDIA DEPENDENT INTERFACE (MDI)

Available format(s)

Hardcopy , PDF

Superseded date

09-12-2005

Superseded by

IEEE 802.3-2012

Language(s)

English

Published date

01-01-2003

REVISIONS TO IEEE Std 802.3-2002
1. (Changes to) Introduction
    1.4 (Changes to) Definitions
    1.5 (Changes to) Abbreviations
14. (Changes to) Twisted-pair medium attachment unit (MAU) and
    baseband medium, type 10BASE-T
22. (Changes to) Reconciliation Sublayer (RS) and Media
    Independent Interface (MII)
30. (Changes to) 10 Mb/s, 100 Mb/s, 1000 Mb/s, and 10 Gb/s
    Management
    30.1 (Changes to) Overview
    30.9 Management for Power Sourcing Equipment (PSE)
    30.10 Layer management for Midspan
40. (Changes to) Physical Coding Sublayer (PCS), Physical
    Medium Attachment (PMA) sublayer and baseband medium, type
    1000BASE-T
ANNEXES
(Changes to) Annex 30A (normative) GDMO specification for
IEEE 802.3 managed object classes
(Changes to) Annex 30B (normative) GDMO and ASN.1 definitions
for management
NEW MATERIAL TO IEEE Std 802.3-2002
33. Data Terminal Equipment (DTE) Power via Media Dependent
    Interface (MDI)
    33.1 Overview
    33.2 Power sourcing equipment
    33.3 Powered devices
    33.4 Additional Electrical specifications
    33.5 Environmental
    33.6 Management function requirements
    33.7 Protocol Implementation Conformance Statement (PICS)
          proforma for Clause 33, DTE Power via MDI
Annex 33A (informative) PSE Detection of PDs
Annex 33B (informative) Cabling guidelines
Annex 33C (informative) Recommended test configurations and
                        procedures
  33C.1 Recommended PSE output test procedures
  33C.2 Recommended PSE AC disconnect-detection test procedures
  33C.3 Recommended PSE detection signature test procedures
  33C.4 Recommended PD detection signature test procedures
  33C.5 Recommended PD power supply test procedures
Annex 33D (informative) PSE-PD stability
  33D.1 Recommended PSE design guidelines and test setup
  33D.2 Recommended PD design guidelines
Annex 33E (informative) Cabling resistance unbalance

Provides support for optionally powering a 10BASE-T, 100BASE-TX or 1000BASE-T DTE device via the Power Interface (PI) using physical layers.

DevelopmentNote
This is an Amendment to IEEE 802.3 (06/2003)
DocumentType
Standard
Pages
133
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

10/30217641 DC : 0 BS IEC PAS 61156-1-4 - SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS WITH TRANSMISSION CHARACTERISTICS UP TO 1000 MHZ - PART 1-4: ASSESSMENT OF THE CONDUCTOR HEATING IN BUNDLED DATA GRADE CABLES DUE TO THE DEPLOYMENT OF POWER TRANSMISSION OVER THE COMMON MODE CIRCUITS OF EITHER 2 OR 4 PAIRS BASED ON THE IEEE 802.3 POE/POEP PROTOCOL
IEC PAS 61156-1-4:2010 Multicore and symmetrical pair/quad cables for digital communications - Part 1-4: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Conductor heating of bundled data grade cables for limited power transmission based on IEEE 802.3
ISO/IEC TR 24704:2004 Information technology — Customer premises cabling for wireless access points
IEEE 602 : 2007 ELECTRIC SYSTEMS IN HEALTH CARE FACILITIES
IEEE 1100 : 2005 POWERING AND GROUNDING ELECTRONIC EQUIPMENT
DD IEC/PAS 61156-1-4:2010 Multicore and symmetrical pair/quad cables for digital communications Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz. Conductor heating of bundled data grade cables for limited power transmission based on IEEE 802.3
CAN/CSA-ISO/IEC TR 24704:2006(R2016) INFORMATION TECHNOLOGY - CUSTOMER PREMISES CABLING FOR WIRELESS ACCESS POINTS
CSA ISO/IEC TR 24704 : 2006 INFORMATION TECHNOLOGY - CUSTOMER PREMISES CABLING FOR WIRELESS ACCESS POINTS
TR 105 174-5-2 : 1.1.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); BROADBAND DEPLOYMENT - ENERGY EFFICIENCY AND BROADBAND DEPLOYMENT; PART 5: CUSTOMER NETWORK INFRASTRUCTURES; SUB-PART 2: OFFICE PREMISES (SINGLE-TENANT)
IEEE DRAFT 802.1AB : D13 2004 LOCAL AND METROPOLITAN NETWORKS: STATION AND MEDIA ACCESS CONTROL CONNECTIVITY DISCOVERY
TS 105 174-7-1 : 1.1.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); BROADBAND DEPLOYMENT AND ENERGY MANAGEMENT; PART 7: DIGITAL MULTISERVICE CITIES; SUB-PART 1: MULTISERVICE STREET FURNITURES
TR 105 174-5-1 : 1.1.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); BROADBAND DEPLOYMENT - ENERGY EFFICIENCY AND KEY PERFORMANCE INDICATORS; PART 5: CUSTOMER NETWORK INFRASTRUCTURES; SUB-PART 1: HOMES (SINGLE-TENANT)
IEC TR 62652:2010 Effects of engaging and separating under electrical load on connector interfaces in cabling used to support IEEE 802.3af (power-over-ethernet) applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more