IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault
30-03-2023
English
21-05-2012
1. Overview
2. Normative references
3. Definitions, acronyms, and abbreviations
4. Overview of technical considerations
5. Electrical power station GPR
6. Calculation of electromagnetic induction
under power fault conditions
7. Vectorial summation of a GPR with an LI voltage
8. Power system fault current probability
9. ZOI of GPR
10. Summary of mitigating and reduction factors
applicable to GPR or induced voltage, or both
11. Communication channel time requirements
12. Administrative guidelines for coordination
between communication and power utilities
Annex A (informative) - Bibliography
Annex B (informative) - Example of calculations for
HV bus fault and LV bus and line fault
Annex C (informative) - Example of a GPR calculation
and volt-time area calculation
Annex D (informative) - Example of calculations for
uniform and nonuniform exposures
Annex E (informative) - Example of calculations for
double-ended supply feed and a telecommunication
line
Annex F (informative) - Examples of calculating the
resultant voltage between the electric power
station ground grid and a conductor that is
grounded at a remote location, such as a
telephone central office
Annex G (informative) - Modeling transfer of ground
potential rise
Annex H (informative) - Sample GPR calculations
Guidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as guidance for their appropriate reduction from worst-case values, for use in metallic telecommunication protection design.
Committee |
Power System Communications and Cybersecurity
|
DevelopmentNote |
Supersedes IEEE DRAFT 367. (08/2002)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-7265-1
|
Pages |
168
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
Supersedes |
IEEE 142 : 2007 | GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEEE 487.3-2014 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Hybrid Facilities |
IEEE C37.122.1-2014 | IEEE Guide for Gas-Insulated Substations Rated Above 52 kV |
IEEE 487.1-2014 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
IEEE C62.23-2017 | IEEE Application Guide for Surge Protection of Electric Generating Plants |
IEEE 3003.1-2019 | IEEE Recommended Practice for System Grounding of Industrial and Commercial Power Systems |
IEEE C62.21 : 2003 | GUIDE FOR THE APPLICATION OF SURGE VOLTAGE PROTECTIVE EQUIPMENT ON AC ROTATING MACHINERY 1000 V AND GREATER |
IEEE 776-1992 | IEEE Recommended Practice for Inductive Coordination of Electric Supply and Communication Lines |
IEEE DRAFT 80 : D14 JUN 99 | DRAFT GUIDE FOR SAFETY IN AC SUBSTATION GROUNDING |
CSA C22.3 No. 8 : 1991 | RAILWAY ELECTRIFICATION GUIDELINES |
IEEE DRAFT 525 : D15 2006 | DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS |
IEEE C62.42-2005 | IEEE Guide for the Application of Component Surge-Protective Devices for Use in Low-Voltage [Equal to or Less than 1000 V (ac) Or 1200 V (dc)] Circuits |
IEEE C62.23-1995 | IEEE Application Guide for Surge Protection of Electric Generating Plants |
CSA C22.3 No. 3 : 1998 | ELECTRICAL COORDINATION |
IEEE 487.2-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations through the Use of Optical Fiber Systems |
IEEE 487.4-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Neutralizing Transformers |
IEEE 487.5-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Isolation Transformers |
IEEE 1137-1991 | IEEE Guide for the Implementation of Inductive Coordination Mitigation Techniques and Application |
IEEE C62.92.6-2017 | IEEE Guide for Application of Neutral Grounding in Electrical Utility Systems, Part VI--Systems Supplied by Current-Regulated Sources |
IEEE 81-2012 | IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System |
IEEE 1124 : 2003 | GUIDE FOR ANALYSIS AND DEFINITION OF DC SIDE HARMONIC PERFORMANCE OF HVDC TRANSMISSION SYSTEMS |
IEEE 1246-2011 REDLINE | IEEE Guide for Temporary Protective Grounding Systems Used in Substations |
IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
NACE SP 01 77 : 2014 | MITIGATION OF ALTERNATING CURRENT AND LIGHTNING EFFECTS ON METALLIC STRUCTURES AND CORROSION CONTROL SYSTEMS |
CSA C22.3 No. 3 : 1998 : INC : UPD 2 : 2002 : R2013 | ELECTRICAL COORDINATION |
IEEE DRAFT 1124 : D8 DEC 97 | DRAFT GUIDE FOR ANALYSIS AND DEFINITION OF DC SIDE HARMONIC PERFORMANCE OF HVDC TRANSMISSION SYSTEMS |
CSA C22.3 No. 3 : 1998:R2007 | ELECTRICAL COORDINATION |
BS 7602:1992 | Guide to general considerations for telecommunication services for electrical power systems |
IEEE 1590-2009 | IEEE Recommended Practice for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Using Optical Fiber Systems |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
IEEE 789-2013 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments |
IEEE 776-2018 | IEEE Recommended Practice for Inductive Coordination of Electric Supply and Communication Lines |
IEEE 1137-2018 | IEEE Recommended Practice for the Implementation of Inductive Coordination Mitigation Techniques and Application |
IEEE 81-1983 | IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part 1: Normal Measurements |
IEEE C37.90-2005 | IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus |
IEEE 80-2000 | IEEE Guide for Safety in AC Substation Grounding |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
IEEE 81-2012 | IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System |
IEEE 487-2007 | IEEE Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply Locations |
IEEE 81.2-1991 | IEEE Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding Systems |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.