IEEE 1434-2014
Current
The latest, up-to-date edition.
IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery
Hardcopy , PDF
English
04-12-2014
1 Overview
2 Normative references
3 Definitions
4 The nature of PD in machine windings
5 Overview of PD detection methods
6 Electrical pulse and RF radiation sensing systems
7 Electrical pulse and RIV measuring instruments
8 Pulse propagation in windings and calibration issues
9 On-line versus off-line testing
10 Test procedures
11 Interpretation of PD test results
Annex A (informative) - Bibliography
Annex B (normative) - Coupling capacitor type tests
and routine tests
Annex C (informative) - Typical PD pulse-phase patterns
(examples)
Annex D (informative) - Typical time-frequency
classification map
Annex E (informative) - Synchronous three channel
multi-spectral analyzer
Annex F (informative) - Electrical pulse and RF radiation
sensing systems in limited use
Annex G (informative) - Interpretive methods in limited
use
This guide discusses both on-line and off-line partial discharge (PD) measurements on complete windings of any type, as well as measurements on individual form-wound coils and bars.
Committee |
Electric Machinery
|
DevelopmentNote |
Supersedes IEEE DRAFT 1434. (09/2000)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-9352-6
|
Pages |
89
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Current
|
Supersedes |
IEEE 3004.8-2016 | IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems |
IEEE 1665 : 2009 | GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE |
ASTM D 3382 : 2013 : REDLINE | Standard Test Methods for Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques |
(INACTIVE RECORD)IEEE C50.12 : 2005 | SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
IEEE 1799-2012 | IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings |
IEEE DRAFT C50.12 : D10 2004 | SALIENT-POLE 50 AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
IEEE DRAFT 434 : D10 2006 | FUNCTIONAL EVALUATION OF INSULATION SYSTEMS FOR AC ELECTRIC MACHINES RATED 2300 V AND ABOVE |
12/30243450 DC : DRAFT FEB 2012 | BS ISO 20958-1 - CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - ELECTRICAL SIGNATURE ANALYSIS - PART 1: THREE-PHASE INDUCTION MOTORS |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
IEEE C50.13 : 2014 | CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE |
ISO 20958:2013 | Condition monitoring and diagnostics of machine systems — Electrical signature analysis of three-phase induction motors |
IEEE DRAFT 67 : D5 2005 | GUIDE FOR THE OPERATION AND MAINTENANCE OF TURBINE GENERATORS |
IEEE 434-2006 | IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above |
ASTM D 1868 : 2013 : REDLINE | Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems |
IEEE 1415 : 2006 | INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS |
IEEE 1129-2014 | IEEE Guide for Online Monitoring of Large Synchronous Generators (10 MVA and Above) |
IEEE 115-2009 REDLINE | IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEC 60034-27-1:2017 | Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation |
CLC/TS 60034-27:2011 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
S.R. CLC/TS 60034-27:2011 | ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
05/30128254 DC : DRAFT JAN 2005 | IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY |
BS ISO 20958:2013 | Condition monitoring and diagnostics of machine systems. Electrical signature analysis of three-phase induction motors |
DD CLC/TS 60034-27:2011 | Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
IEEE 1310-2012 REDLINE | IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines |
IEEE 1349-2011 REDLINE | IEEE Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations |
IEEE 56-2016 | IEEE Guide for Insulation Maintenance of Electric Machines |
IEEE 115-2019 | IEEE Guide for Test Procedures for Synchronous Machines Including Acceptance and Performance Testing and Parameter Determination for Dynamic Analysis |
IEEE 2465-2023 | IEEE Trial-Use Recommended Practice for Pulse-Type Partial Discharge Measurements on Individual Stator Coils and Bars |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
NEMA 107:2016 | Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
IEC TS 61934:2011 | Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses |
IEEE 510-1983 | IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing |
IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
ASTM D 2303 : 2013 | Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials |
ASTM D 3382 : 2013 : REDLINE | Standard Test Methods for Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques |
IEEE 433-2009 REDLINE | IEEE Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage at Very Low Frequency |
IEEE C37.20.2-1999 | IEEE Standard for Metal-Clad Switchgear |
IEEE 1799-2012 | IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings |
IEC TS 60034-27-2:2012 | Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
ASTM D 1868 : 2013 : REDLINE | Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems |
API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
IEEE 286-2000 | IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-