IEEE 1247 : 2005
Current
The latest, up-to-date edition.
INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V
Hardcopy , PDF
English
01-01-2006
1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Definitions
4 Service conditions
4.1 Usual service conditions
4.2 Unusual service conditions
5 Description of ratings and capabilities
5.1 Rated power frequency
5.2 Rated voltage
5.3 Rated withstand voltages
5.4 Rated currents
5.5 Rated ice breaking ability
5.6 Rated control voltage
5.7 Rated mechanical operations
5.8 Rated mechanical terminal load
5.9 Visible corona-free voltage
5.10 Radio-influence voltage limit
5.11 Partial discharge limits
6 Preferred ratings
6.1 Preferred ratings - Outdoor switches
6.2 Preferred ratings - Indoor switches
6.3 Preferred ratings - Enclosed switches
6.4 Other preferred ratings
7 Construction requirements
7.1 Nameplates
7.2 Contact position indicator
7.3 Accessories
7.4 Instructions
7.5 Terminal pads
8 Test code
8.1 Withstand voltage tests
8.2 Continuous current tests
8.3 Switching tests
8.4 Short-time withstand current tests
8.5 Fault-making current test
8.6 Condition of the switch after each test of 8.3, 8.4, and 8.5
8.7 Ice loading test
8.8 Mechanical operation tests
8.9 Corona tests
8.10 Radio-influence tests
8.11 Partial discharge test
8.12 Production tests
Annex A (informative) Altitude correction factors
Annex B (informative) Load-switching TRV
Annex C (informative) Restrike-free performance
Annex D (informative) Capacitive current switching
Annex E (informative) Bibliography
The basic requirements of interrupter switches used indoors, outdoors, and in enclosures are covered.
DevelopmentNote |
Supersedes IEEE DRAFT 1247. (06/2006)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-4865-6
|
Pages |
72
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Current
|
Supersedes |
IEEE DRAFT 1036 : D13A 2006 | APPLICATION OF SHUNT POWER CAPACITORS |
IEEE C37.100.2-2018 | IEEE Standard for Common Requirements for Testing of AC Capacitive Current Switching Devices over 1000 V |
IEEE C37.66 : 2005 | REQUIREMENTS FOR CAPACITOR SWITCHES FOR AC SYSTEMS (1 KV TO 38 KV) |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
IEEE C37.016-2006 | IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kV |
IEEE C37.74-2014 | IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV |
IEEE 1036-2010 | IEEE Guide for the Application of Shunt Power Capacitors |
IEEE C37.32-2002 | American National Standard for High Voltage Switches, Bus Supports, and Accessories Schedules of Preferred Ratings, Construction Guidelines, and Specifications |
IEEE C37.63-2013 REDLINE | IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV |
IEEE C37.20.4-2013 REDLINE | IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear |
IEEE C37.41-2008 REDLINE | IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices |
IEEE C37.32-2002 | American National Standard for High Voltage Switches, Bus Supports, and Accessories Schedules of Preferred Ratings, Construction Guidelines, and Specifications |
ANSI C37.57 : 1990 | SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING |
NEMA SG 6:2000 | POWER SWITCHING EQUIPMENT |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
NEMA 107:2016 | Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus |
IEEE C37.74-2014 | IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
IEC 60265-2:1988 | High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above |
ANSI C29.1 : 1988 | TEST METHODS FOR ELECTRICAL POWER INSULATORS |
ANSI C37.58 : 1990 | INDOOR AC MEDIUM-VOLTAGE SWITCHES FOR USE IN METAL-ENCLOSED SWITCHGEAR - CONFORMANCE TEST PROCEDURES |
IEEE C37.66 : 2005 | REQUIREMENTS FOR CAPACITOR SWITCHES FOR AC SYSTEMS (1 KV TO 38 KV) |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE C37.20.3-2013 REDLINE | IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV) |
IEEE C37.20.4-2013 REDLINE | IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear |
IEEE C37.010-1999 | IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
IEEE C37.34-1994 | IEEE Standard Test Code for High-Voltage Air Switches |
IEEE C63.2-2009 | American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.41-2008 REDLINE | IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices |
IEEE C37.30-1997 | IEEE Standard Requirements for High Voltage Switches |
ANSI C37.22:1997 | AMERICAN NATIONAL STANDARD PREFERRED RATINGS AND RELATED REQUIRED CAPABLITIES FOR INDOOR AC MEDIUM VOLTAGE SWITCHES USED IN METAL-ENCLOSED SWITCHGEAR |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.