IEC TS 61850-80-1:2016
Current
The latest, up-to-date edition.
Communication networks and systems for power utility automation - Part 80-1: Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
28-07-2016
FOREWORD
1 Scope
2 Normative references
3 Abbreviated terms
4 The mapping architecture
5 Conceptual architectures and associated use cases
6 Mapping of a device-oriented information model to
IEC 60870-5-104 or IEC 60870-5-101
7 Mapping of the common data classes (CDC)
8 Mapping of services
9 Protocol stack selections for IEC 60870-5-101 and
IEC 60870-5-104
Annex A (informative) - Use of SCL (substation
configuration language) to include
IEC 60870-5-101 or IEC 60870-5-104
information
Bibliography
IEC TS 61850-80-1:2016(E) gives a guideline on how to exchange information from a CDC-based data model (for example IEC 61850) using IEC 60870-5-101 or IEC 60870-5-104 between substation(s) and control center(s). Mostly guidelines for functions needed in a substation gateway device are given. The goal of this technical specification is to describe standardized mapping of device-oriented data models (for example IEC 61850) with already defined attributes of CDCs and services (for example IEC 61850-7) onto the already defined ASDUs and services of IEC 60870-5-104 or IEC 60870-5-101. This second edition includes the following significant technical changes with respect to the previous edition: it makes reference to Edition 2 standards of the IEC 61850 series, more particularly to IEC 61850-7-3:2010, which introduces new Common Data Classes (CDCs).
Committee |
TC 57
|
DevelopmentNote |
Stability Date: 2019. (08/2016)
|
DocumentType |
Technical Specification
|
Pages |
173
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD IEC/TS 61850-80-1:2016 | Identical |
NEN NPR CLC IEC/TS 61850-80-1 : 2010 | Identical |
S.R. CLC/TS 61850-80-1:2010 | Identical |
DD IEC TS 61850-80-1 : DRAFT JAN 2009 | Identical |
NEN NPR IEC/TS 61850-80-1 : 2009 | Identical |
CLC/TS 61850-80-1:2010 | Identical |
IEC TS 62786:2017 | Distributed energy resources connection with the grid |
IEC TR 61850-1:2013 | Communication networks and systems for power utility automation - Part 1: Introduction and overview |
IEC 61400-25-4:2016 RLV | Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile |
EN 61400-25-4:2017 | Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile |
PD IEC/TS 62786:2017 | Distributed energy resources connection with the grid |
BS EN 61400-25-4:2008 | Wind turbines Communications for monitoring and control of wind power plants. Mapping to communication profile |
PD IEC/TR 61850-1:2013 | Communication networks and systems for power utility automation Introduction and overview |
CEI EN 61400-25-4 : 2009 | WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE |
NF EN 61400-25-4 : 2017 | WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE |
IEC 61400-25-4:2016 | Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile |
I.S. EN 61400-25-4:2017 | WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE |
IEEE 2030.100-2017 | IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
IEC 60870-5-4:1993 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 4: Definition and coding of application information elements |
IEC 61850-6:2009 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEC 60870-5-104:2006+AMD1:2016 CSV | Telecontrol equipment and systems - Part 5-104: Transmission protocols - Network access for IEC 60870-5-101 using standardtransport profiles |
IEC 60870-5-101:2003+AMD1:2015 CSV | Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks |
IEC 60870-5-5:1995 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions |
IEC 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC 61850-7-3:2010 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
IEEE 754-2008 REDLINE | IEEE Standard for Floating-Point Arithmetic |
IEC 60870-5-3:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data |
IEC 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.