FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Methods of seismic qualification
6 Severities
7 Qualification by static calculation
8 Qualification by dynamic analysis
9 Qualification by vibration test
10 Evaluation of the seismic qualification
11 Necessary exchange of information
Annex A (informative) - Flow chart for seismic
        qualification
Annex B (informative) - Natural frequency and
        damping determination: Free oscillation
        test
Annex C (informative) - Static calculation method
        - Additional considerations
Annex D (informative) - Qualification by static
        calculation - Example on transformer
        bushing
Annex E (informative) - Center clamped bushings
Bibliography

IEC TS 61463:2016(E), which is a Technical Specification, is applicable to alternating current and direct current bushings for highest voltages above 52 kV (or with resonance frequencies placed inside the seismic response spectrum), mounted on transformers, other apparatus or buildings. For bushings with highest voltages less than or equal to 52 kV (or with resonance frequencies placed outside from the seismic response spectrum), due to their characteristics, seismic qualification is not used as far as construction practice and seismic construction practice comply with the state of the art. This document presents acceptable seismic qualification methods and requirements to demonstrate that a bushing can maintain its mechanical properties, insulate and carry current during and after an earthquake. The seismic qualification of a bushing is only performed upon request.

Committee
TC 36/SC 36A
DevelopmentNote
Stability Date: 2019. (07/2016)
DocumentType
Technical Specification
Pages
40
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
PD IEC/TS 61463:2016 Identical
IS/IEC/TS 61463 : 2016 Identical
BS EN 61210:2010 Identical

CEI EN 62271-207 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
BS IEC/IEEE 65700-19-03 : 2014 BUSHINGS FOR DC APPLICATION
CSA C62155 : 2006 : R2015 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
I.S. EN 60137:2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
CEI EN 62199 : 2005 BUSHINGS FOR D.C. APPLICATION
EN 60137:2017 Insulated bushings for alternating voltages above 1 000 V
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
EN 62199:2004 Bushings for d.c. application
NF EN 62155 : 2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
BS EN 62199:2004 Bushings for D.C. application
04/30111589 DC : 0
CSA C62155:2006 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
BS EN 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
IEC/IEEE 65700-19-03:2014 Bushings for DC application
IEC 60137:2017 RLV Insulated bushings for alternating voltages above 1000 V
UNE-EN 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
12/30274727 DC : 0 BS EN 61936-1 AMD 1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
I.S. EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV))
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
I.S. EN 62199:2004 BUSHINGS FOR D.C. APPLICATION
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
BS EN 62271-207:2012 High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
16/30318517 DC : 0 BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
I.S. EN 62155:2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
IEC 62199:2004 Bushings for d.c. application
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
10/30232728 DC : 0 BS EN 62271-207 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
BS EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
CSA C62155 : 2006 : R2011 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
I.S. EN IEC/IEEE 65700:2018 BUSHINGS FOR DC APPLICATION
CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012)

IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
IEC 60068-3-3:1991 Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
ISO 2041:2009 Mechanical vibration, shock and condition monitoring Vocabulary
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60721-2-6:1990 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock
IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more