IEC TR 61850-90-1:2010
Current
The latest, up-to-date edition.
Communication networks and systems for power utility automation - Part 90-1: Use of IEC 61850 for the communication between substations
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
16-03-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Use cases
6 Communication requirements for substation-to-substation
communication
7 Considerations on security and dependability issues when
using Ethernet networks
8 Communication aspects
9 Modelling
10 Configuration aspects
Bibliography
IEC/TR 61850-90-1:2010(E) provides a comprehensive overview on the different aspects that need to be considered while using IEC 61850 for information exchange between substations. In particular, this technical report defines use cases that:
- require an information exchange between substations;
- describes the communication requirements;
- gives guidelines for the communication services and communication architecture to be used;
- defines data as a prerequisite for interoperable applications;
-describes the usage and enhancements of the configuration language SCL.
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Technical Report
|
Pages |
79
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
SupersededBy |
Standards | Relationship |
PD IEC/TR 61850-90-1:2010 | Identical |
PD IEC/TR 61850-7-500:2017 | Communication networks and systems for power utility automation Basic information and communication structure. Use of logical nodes for modeling application functions and related concepts and guidelines for substations |
IEC TR 61850-1:2013 | Communication networks and systems for power utility automation - Part 1: Introduction and overview |
PD IEC/TR 61850-90-12:2015 | Communication networks and systems for power utility automation Wide area network engineering guidelines |
I.S. EN 61850-7-1:2011 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-1: BASIC COMMUNICATION STRUCTURE - PRINCIPLES AND MODELS (IEC 61850-7-1:2011 (EQV)) |
IEEE C37.243-2015 | IEEE Guide for Application of Digital Line Current Differential Relays Using Digital Communication |
PD IEC/TR 61850-1:2013 | Communication networks and systems for power utility automation Introduction and overview |
PD IEC/TR 61850-90-4:2013 | Communication networks and systems for power utility automation Network engineering guidelines |
BS EN 61850-7-1:2011 | Communication networks and systems for power utility automation Basic communication structure. Principles and models |
BS EN 61850-5:2013 | Communication networks and systems for power utility automation Communication requirements for functions and device models |
IEC TR 62357-200:2015 | Power systems management and associated information exchange - Part 200: Guidelines for migration from Internet Protocol version 4 (IPv4) to Internet Protocol version 6 (IPv6) |
IEC TR 61850-90-5:2012 | Communication networks and systems for power utility automation - Part 90-5: Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118 |
EN 61850-7-1:2011 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-1: BASIC COMMUNICATION STRUCTURE - PRINCIPLES AND MODELS (IEC 61850-7-1:2011) |
CEI EN 61850-7-1 : 2012 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-1: BASIC COMMUNICATION STRUCTURE - PRINCIPLES AND MODELS |
PD IEC/TR 61850-90-5:2012 | Communication networks and systems for power utility automation Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118 |
PD IEC/TR 62357-200:2015 | Power systems management and associated information exchange Guidelines for migration from Internet Protocol version 4 (IPv4) to Internet Protocol version 6 (IPv6) |
IEC TR 61850-7-500:2017 | Communication networks and systems for power utility automation - Part 7-500: Basic information and communication structure - Use of logical nodes for modeling application functions and related concepts and guidelines for substations |
IEC 61850-7-1:2011 | Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models |
IEEE 2030.100-2017 | IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System |
I.S. EN 61850-5:2013 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 5: COMMUNICATION REQUIREMENTS FOR FUNCTIONS AND DEVICE MODELS (IEC 61850-5:2013 (EQV)) |
IEC 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
EN 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
IEC 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
IEC TS 62351-6:2007 | Power systems management and associated information exchange - Data and communications security - Part 6: Security for IEC 61850 |
IEC 62439:2008 | High availability automation networks |
IEC 61850-6:2009 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEEE 802.1Q-2014 | IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks |
IEC 60870-4:1990 | Telecontrol equipment and systems. Part 4: Performance requirements |
IEC 60834-2:1993 | Performance and testing of teleprotection equipment of power systems - Part 2: Analogue comparison systems |
IEC 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC 61850-9-2:2011 | Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
IEC 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
IEC 62053-22:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - Particular Requirements - Part 22: Static meters for active energy (classes 0,2 S and 0,5 S) |
IEEE 1588-2008 REDLINE | IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems |
IEC TS 61850-2:2003 | Communication networks and systems in substations - Part 2: Glossary |
IEC 61850-3:2013 | Communication networks and systems for power utility automation - Part 3: General requirements |
IEC 60834-1:1999 | Teleprotection equipment of power systems - Performance and testing - Part 1: Command systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.