IEC TR 61000-4-35:2009
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 4-35: Testing and measurement techniques - HPEM simulator compendium
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
23-07-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Datasheet definitions and instructions
6 Project description
6.1 General
6.2 Wideband and ultra wideband simulator
6.3 Narrowband simulator
6.4 Reverberation chamber
7 Datasheets
7.1 Wideband simulator
HIRA II- PBG, Germany
AVTOARRESTOR, Ukraine
7.2 Narrowband simulator
HPM 3 GHz, 6 GHz and 9 GHz, Czech Republic
HYPERION, France
MELUSINE, France
EMCC Dr. Rasek HIRF-Simulator, Germany
SUPRA, Germany
SP Faraday, Sweden
MTF, Sweden
ORION, United Kingdom
Radio Frequency Environment Generator (REG), United Kingdom
7.3 Reverberation chambers
Large Magdeburg Reverberation Chamber, Germany
CISAM Aluminium Reverberation Chamber, Italy
Environ Laboratories Reverberation Chamber, USA
QinetiQ Medium Reverberation Chamber (QMRC), United Kingdom
Bibliography
IEC/TR 61000-4-35:2009(E) provides information about extant system-level High-Power Electromagnetic (HPEM) simulators and their applicability as test facilities and validation tools for immunity test requirements in accordance with the IEC 61000 series of standards. HPEM simulators with the capability of conducted susceptibility or immunity testing will be included in a further stage of the project. In the sense of this report the group of HPEM simulators consists of narrow band microwave test facilities and wideband simulators for radiated high power electromagnetic fields. IEC 61000-2-13 defines high power electromagnetic (HPEM) radiated environments as those with a peak power density that exceeds 26 W/m2 (100 V/m or 0,27 A/m). This part of IEC 61000 focuses on a sub-set of HPEM simulators capable of achieving much higher fields. Therefore, the HPEM radiated environments used in this document are characterized by a peak power density exceeding 663 W/m2 (500 V/m or 1,33 A/m). The intention of this report is to provide the first detailed listing of both narrowband (hypoband) and wideband (mesoband, sub-hyperband and hyperband) simulators throughout the world. HEMP simulators are the subject of a separate compendium (IEC 61000-4-32) and thus are outside the scope of this Technical Report. After an introduction, a general description of HPEM simulators, as listed in this Technical Report, is presented. A database has been created by collecting information from simulator owners and operators and this data is presented for the technical characterization of the test facilities. In addition, some important commercial aspects, such as availability and operational status, are also addressed.
DevelopmentNote |
Stability Date: 2016. (10/2012)
|
DocumentType |
Technical Report
|
Pages |
81
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
PD IEC/TR 61000-4-35:2009 | Identical |
NEN NPR IEC/TR 61000-4-35 : 2009 | Identical |
13/30286075 DC : 0 | BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
PD IEC/TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI |
IEC TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM |
IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) - Part 4-36: Testing and measurement techniques - IEMI immunity test methods for equipment and systems |
DD IEC/TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM |
BS IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) Testing and measurement techniques. IEMI immunity test methods for equipment and systems |
IEC TR 61000-4-1:2016 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI |
IEC 61000-2-10:1998 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
SA TR IEC 61000.2.5:2019 | Electromagnetic compatibility (EMC) Environment - Description and classification of electromagnetic environments |
IEEE 145-2013 REDLINE | IEEE Standard for Definitions of Terms for Antennas |
IEC 61000-2-9:1996 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication |
IEC 61000-2-13:2005 | Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted |
IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |