FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 General recommendations
5 ME EQUIPMENT and ME SYSTEMS identification,
marking and documents
6 Documentation of the tests
7 EMISSIONS
8 IMMUNITY recommendations
9 Test report
Annex A (informative) - General guidance and
rationale
Annex B (informative) - Guide to labelling
recommendations
Annex C (informative) - Determination of
IMMUNITY TEST LEVELS for SPECIAL
ENVIRONMENTS
Annex D (informative) - Identification of
specific IMMUNITY performance criteria
Annex E (informative) - Performance criteria
specified by IEC 61000-6-x generic EMC
standards
Annex F (informative) - Mapping between this
document and the elements of IEC 60601-1-2:2014
Bibliography
Index of defined terms used in this technical report
IEC TR 60601-4-2:2016(E) applies to the performance of medical electrical equipment or a medical electrical system in the presence of electromagnetic disturbances.
Committee |
TC 62/SC 62A
|
DevelopmentNote |
Stability date: 2019. (05/2016)
|
DocumentType |
Technical Report
|
ISBN |
978-2-8322-3414-3
|
Pages |
57
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN NPR IEC/TR 60601-4-2 : 2016 | Identical |
PD IEC/TR 60601-4-2:2016 | Identical |
DS IEC/TR 60601-4-2 : 2016 | Identical |
IEEE/ANSI C63.15-2010 | American National Standard Recommended Practice for the Immunity Measurement of Electrical and Electronic Equipment |
AAMI TIR69 : 2017 | RISK MANAGEMENT OF RADIO-FREQUENCY WIRELESS COEXISTENCE FOR MEDICAL DEVICES AND SYSTEMS |
ISO 16750-2:2012 | Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 2: Electrical loads |
IEC 60601-2-3:2012+AMD1:2016 CSV | Medical electrical equipment - Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC TS 61000-1-2:2008 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
IEC TR 61000-4-1:2016 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
ISO 7637-2:2011 | Road vehicles Electrical disturbances from conduction and coupling Part 2: Electrical transient conduction along supply lines only |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 60601-2-25:2011 | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs |
ISO 7137:1995 | Aircraft — Environmental conditions and test procedures for airborne equipment |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CISPR 24:2010+AMD1:2015 CSV | Information technology equipment - Immunity characteristics - Limitsand methods of measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.