IEC PAS 61156-1-4:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Multicore and symmetrical pair/quad cables for digital communications - Part 1-4: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Conductor heating of bundled data grade cables for limited power transmission based on IEEE 802.3
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English
28-06-2010
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions, symbols, units and abbreviated
terms
4 The testing of bundled cables
5 The temperature as a function of the current load
in conductors of bundled cables in hexagonal densest
packing structure
6 Assessing already deployed cable systems
7 The higher performing data grade cables
8 The heat dissipation on heated and bundled cables
9 The heat dissipation in a heated conductor, pair or
cable which has to be taken into account
10 Thermodynamic considerations for a combined
experimental and mathematical solution of the
heating problem
IEC/PAS 61156-1-4:2010(E) is covering exclusively four-pair data grade cables and is intended to provide a test method for the determination of the maximum attained conductor temperatures which occur due to the deployment of the IEEE protocol for PoE /PoEP. It gives as well the required background information about the thermodynamic behaviour of such bundled cables, if they are located in areas with restricted heat dissipation, a reality which occurs in every installation situation. However, only the basic principles are given, as the rigorous application and solution of these problems fall into the relevant cabling standards.
Committee |
TC 46/SC 46C
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Miscellaneous Product
|
Pages |
42
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN NPR IEC/PAS 61156-1-4 : 2010 | Identical |
DD IEC/PAS 61156-1-4:2010 | Identical |
BS IEC 61156-10:2016 | Multicore and symmetrical pair/quad cables for digital communications Cables for cords with transmission characteristics up to 2 GHz. Sectional specification |
PD IEC/TR 61156-1-6:2016 | Multicore and symmetrical pair/quad cables for digital communications Nominal DC-resistance values of floor-wiring and work-area cables for digital communications |
IEC 61156-10:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 10: Cables for cords with transmission characteristics up to 2 GHz - Sectional specification |
BS IEC 61156-9:2016 | Multicore and symmetrical pair/quad cables for digital communications Cables for channels with transmission characteristics up to 2 GHz. Sectional specification |
IEC 61156-9:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 9: Cables for channels with transmission characteristics up to 2 GHz - Sectional specification |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 61156-6:2010+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Work area wiring -Sectional specification |
IEEE 802.3AF : 2003 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS - AMENDMENT: DATA TERMINAL EQUIPMENT (DTE) POWER VIA MEDIA DEPENDENT INTERFACE (MDI) |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEEE 802.3AT : 2009 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS - AMENDMENT 3: DATA TERMINAL EQUIPMENT (DTE) POWER VIA THE MEDIA DEPENDENT INTERFACE (MDI) ENHANCEMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.