IEC 62135-2:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-01-2022
English - French
24-02-2015
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General test requirements
5 Test set-up for emission and immunity
6 Emission tests
7 Immunity tests
8 Documentation for the purchaser/user
Annex A (informative) - Limits
Annex B (informative) - Symbols
Bibliography
IEC 62135-2:2015 is applicable to equipment for resistance welding and allied processes which are connected to mains supplies with rated voltages up to 1 000 V a.c. r.m.s. This standard does not define safety requirements. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of the applicable limits related to the updated reference to CISPR 11;
- exclusion of the use of narrow band relaxations for RF emission limits;
- update of the applicable limits for harmonics and flicker related to the updated reference to IEC 61000-3-11 and IEC 61000-3-12;
- update of the requirements for voltage dips related to the updated reference to IEC 61000-4-11 and IEC 61000-4-34;
- inclusion of symbols to indicate the RF equipment class and restrictions for use;
- inclusion of EM field immunity test for frequency from 1,4 GHz to 2,7 GHz;
- inclusion of emission limits for class B resistance welding equipment magnetic fields between 150 kHz and 30 MHz.
Committee |
TC 26
|
DevelopmentNote |
Stability date: 2018. (02/2015)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 62135-2:2015 | Identical |
OVE/ONORM EN 62135-2 : 2015 | Identical |
NBN EN 62135-2 : 2015 | Identical |
NEN EN IEC 62135-2 : 2015 | Identical |
SAC GB 31251-2 : 2014 | Identical |
DIN EN 62135-2 : 2015 | Identical |
BS EN 62135-2:2015 | Identical |
UNE-EN 62135-2:2008 | Identical |
EN 62135-2:2015 | Identical |
NF EN 62135-2 : 2015 | Identical |
PN EN 62135-2 : 2015 | Identical |
IEC 62135-2:2020 | Identical |
UNE-EN 62135-2:2015 | Identical |
VDE 0545-2 : 2015 | Identical |
PNE-FprEN 62135-2 | Identical |
15/30318290 DC : 0 | BS EN ISO 17662 - WELDING - CALIBRATION, VERIFICATION AND VALIDATION OF EQUIPMENT USED FOR WELDING, INCLUDING ANCILLARY ACTIVITIES |
UNE-EN ISO 17662:2016 | Welding - Calibration, verification and validation of equipment used for welding, including ancillary activities (ISO 17662:2016) |
I.S. EN ISO 17662:2016 | WELDING - CALIBRATION, VERIFICATION AND VALIDATION OF EQUIPMENT USED FOR WELDING, INCLUDING ANCILLARY ACTIVITIES (ISO 17662:2016) |
UNE-EN 55011:2011 | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
BS EN 55011 : 2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
DIN EN ISO 17662:2016-09 | WELDING - CALIBRATION, VERIFICATION AND VALIDATION OF EQUIPMENT USED FOR WELDING, INCLUDING ANCILLARY ACTIVITIES (ISO 17662:2016) |
IEC 62135-1:2015 | Resistance welding equipment - Part 1: Safety requirements for design, manufacture and installation |
I.S. EN 55011:2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
CEI EN 55011 : 2017 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
I.S. EN 62135-1:2015 | RESISTANCE WELDING EQUIPMENT - PART 1: SAFETY REQUIREMENTS FOR DESIGN, MANUFACTURE AND INSTALLATION |
EN ISO 17662:2016 | Welding - Calibration, verification and validation of equipment used for welding, including ancillary activities (ISO 17662:2016) |
12/30263969 DC : 0 | BS EN 55011 - GENERAL MAINTENANCE FOR CISPR 11 ED.5.1 |
NF EN 55011 : 2016 AMD 1 2017 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
ISO 17662:2016 | Welding — Calibration, verification and validation of equipment used for welding, including ancillary activities |
BS EN ISO 17662:2016 | Welding. Calibration, verification and validation of equipment used for welding, including ancillary activities |
BS EN 62135-1:2015 | Resistance welding equipment Safety requirements for design, manufacture and installation |
EN 62135-1:2015/AC:2016-02 | RESISTANCE WELDING EQUIPMENT - PART 1: SAFETY REQUIREMENTS FOR DESIGN, MANUFACTURE AND INSTALLATION |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC TR 61000-3-7:2008 | Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC TS 61000-3-4:1998 | Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A |
IEC 62135-1:2015 | Resistance welding equipment - Part 1: Safety requirements for design, manufacture and installation |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
ISO 669:2016 | Resistance welding Resistance welding equipment Mechanical and electrical requirements |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
IEC 60050-851:2008 | International Electrotechnical Vocabulary (IEV) - Part 851: Electric welding |
IEC 61000-4-34:2005+AMD1:2009 CSV | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.