Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61967-2:2005

Current

Current

The latest, up-to-date edition.

Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 2: Measurement of radiated emissions - TEM cell and wideband TEM cell method

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

29-09-2005

$273.25
Including GST where applicable

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test conditions
   5.1 General
   5.2 Supply voltage
   5.3 Frequency range
6 Test equipment
   6.1 General
   6.2 Shielding
   6.3 RF measuring instrument
   6.4 Preamplifier
   6.5 TEM cell
   6.6 Wideband TEM/GTEM cell
   6.7 50-Ohm termination
   6.8 System gain
7 Test set-up
   7.1 General
   7.2 Test configuration
   7.3 Test PCB
8 Test procedure
   8.1 General
   8.2 Ambient measurement
   8.3 DUT operational check
   8.4 DUT emissions measurement
9 Test report
   9.1 General
   9.2 Measurement conditions
10 IC emissions reference levels
Annex A (informative) Example calibration & set-up
                      verification sheet
Annex B (informative) TEM cell and wideband TEM cell
                      descriptions
   B.1 TEM cell
   B.2 Wideband GTEM cell
Annex C (informative) Calculation of dipole moment from
                      measured data
   C.1 General
   C.2 Dipole moment calculation
Annex D (informative) Specification of emissions data
   D.1 General
   D.2 Specification of emission levels
   D.3 Presentation of results
   D.4 Examples
Bibliography

This test procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a transverse electromagnetic (TEM) or wideband gigahertz TEM (GTEM) cell. The test board is not inside the cell, as in the conventional usage, but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured radio frequency (RF) voltage will be affected by many factors. The primary factor affecting the measured RF voltage is the septum to IC test board (cell wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to floor spacing of 45 mm and a GTEM cell with average septum to floor spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations. A conversion factor may allow comparisons between data measured on TEM or GTEM cells with different septum to floor spacing. The IC test board controls the geometry and orientation of the operating IC relative to the cell and eliminates any connecting leads within the cell (these are on the backside of the board, which is outside the cell). For the TEM cell, one of the 50 ports is terminated with a 50 load. The other 50 port for a TEM cell, or the single 50 port for a GTEM cell, is connected to the input of a spectrum analyser or receiver that measures the RF emissions emanating from the integrated circuit and impressed onto the septum of the cell.

DevelopmentNote
To be read in conjunction with IEC 61967-1. (10/2005) Stability Date: 2017. (10/2012)
DocumentType
Standard
Pages
43
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
UNE-EN 61967-2:2005 Identical
EN 61967-2:2005 Identical
DIN EN 61967-2:2006-03 Identical
NEN EN IEC 61967-2 : 2005 Identical
I.S. EN 61967-2:2005 Identical
PN EN 61967-2 : 2006 Identical
SN EN 61967-2 : 2005 Identical
BS EN 61967-2:2005 Identical
CEI EN 61967-2 : 2006 Identical
NF EN 61967-2 : 2006 Identical

BS EN 61967-8:2011 Integrated circuits. Measurement of electromagnetic emissions Measurement of radiated emissions. IC stripline method
PD IEC/TR 61967-4-1:2005 Integrated circuits. Measurement of electromagnetic emissions, 150 kHz to 1 GHz Measurement of conducted emissions. 1 Ohm/150 Ohm direct coupling method. Application guidance to IEC 61967-4
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
EN 62132-2:2011 Integrated circuits - Measurement of electromagnetic immunity - Part 2: Measurement of radiated immunity - TEM cell and wideband TEM cell method
EN 61967-5:2003 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 5: Measurement of conducted emissions - Workbench Faraday Cage method
06/30152634 DC : DRAFT JULY 2006
BS EN 61000-4-20:2003 Electromagnetic Compatibility (EMC) Testing and measurement techniques. Emission and immunity testing in transverse electromagnetic (TEM) waveguides
CEI EN 61967-1 : 2002 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 1: GENERAL CONDITIONS AND DEFINITIONS
I.S. EN 61967-8:2011 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS - PART 8: MEASUREMENT OF RADIATED EMISSIONS - IC STRIPLINE METHOD (IEC 61967-8:2011 (EQV))
CEI EN 61000-4-20 : 2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
EN IEC 62969-1:2018 Semiconductor devices - Semiconductor interface for automotive vehicles - Part 1: General requirements of power interface for automotive vehicle sensors
CEI EN 61967-8 : 2012 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS - PART 8: MEASUREMENT OF RADIATED EMISSIONS - IC STRIPLINE METHOD
BS ISO 18257:2016 Space systems. Semiconductor integrated circuits for space applications. Design requirements
09/30191126 DC : DRAFT FEB 2009 BS EN 62132-8 - INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY - PART 8: MEASUREMENT OF RADIATED IMMUNITY - IC STRIP LINE METHOD
BS EN 62132-2:2011 Integrated circuits. Measurement of electromagnetic immunity Measurement of radiated immunity. TEM cell and wideband TEM cell method
I.S. EN 61967-5:2003 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 5: MEASUREMENT OF CONDUCTED EMISSIONS - WORKBENCH FARADAY CAGE METHOD
IEC 62969-1:2017 Semiconductor devices - Semiconductor interface for automotive vehicles - Part 1: General requirements of power interface for automotive vehicle sensors
NF EN 62132-2 : 2011 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY - PART 2: MEASUREMENT OF RADIATED IMMUNITY - TEM CELL AND WIDEBAND TEM CELL METHOD
BS EN 61967-5:2003 Integrated circuits. Measurement of electromagnetic emissions, 150 kHz to 1 GHz Measurement of conducted emissions. Workbench Faraday Cage method
I.S. EN 62132-2:2011 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY - PART 2: MEASUREMENT OF RADIATED IMMUNITY - TEM CELL AND WIDEBAND TEM CELL METHOD
ISO 18257:2016 Space systems — Semiconductor integrated circuits for space applications — Design requirements
I.S. EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
UNE-EN 61000-4-20:2011 Electromagnetic compatibility (EMC) -- Part 4-20: Testing and measurement techniques - Emission and immunity testing in Transverse Electromagnetic (TEM) waveguides - Basic EMC publication
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC 61967-1:2002 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions
IEC 62132-2:2010 Integrated circuits - Measurement of electromagnetic immunity - Part 2: Measurement of radiated immunity - TEM cell and wideband TEM cell method
EN 61967-8 : 2011 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS - PART 8: MEASUREMENT OF RADIATED EMISSIONS - IC STRIPLINE METHOD
16/30336986 DC : 0 BS EN 62969-1 - SEMICONDUCTOR DEVICES - SEMICONDUCTOR INTERFACE FOR AUTOMOTIVE VEHICLES - PART 1: GENERAL REQUIREMENTS OF POWER INTERFACE FOR AUTOMOTIVE VEHICLE SENSORS
CEI EN 62132-2 : 2012 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY PART 2: MEASUREMENT OF RADIATED IMMUNITY - TEM CELL AND WIDEBAND TEM CELL METHOD
06/30151320 DC : DRAFT JUN 2006 BS IEC 62132-2 - INTEGRATED CIRCUITS, MEASUREMENT OF ELECTRO MAGNETIC IMMUNITY, 150 KHZ TO 1 GHZ - PART 2: MEASUREMENT OF RADIATED 1 MM UNITY TEM-CELL AND WIDEBAND TEM-CELLMETHOD
IEC TR 61967-4-1:2005 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 4-1: Measurement of conducted emissions - 1 Ω/150 Ω direct coupling method - Application guidance to IEC 61967-4
IEC 61967-8:2011 Integrated circuits - Measurement of electromagnetic emissions - Part 8: Measurement of radiated emissions - IC stripline method

IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
CISPR 16-2-2:2010 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power
IEC 61967-1:2002 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
CISPR 16-1-3:2004+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 16-1-5:2014+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
CISPR 16-2-4:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more