IEC 61812-1:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Time relays for industrial and residential use - Part 1: Requirements and tests
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-06-2023
English, English - French, Spanish, Castilian
25-05-2011
IEC 61812-1:2011 applies to time relays for industrial applications (e.g. control, automation, signal and industrial equipment). It also applies to time relays for automatic electrical controls for use in, on, or in association with equipment for residential and similar use. This edition includes the following significant technical changes with respect to the previous edition:
- addition of terms and definitions more commonly used by industry;
- addition of timing charts to help explain terms and definitions involving a sequence of events;
- addition of provisions for residential use.
Committee |
TC 94
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
94
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
JIS C 61812-1:2014 | Identical |
NF EN 61812-1 : 2013 | Identical |
GOST IEC 61812-1 : 2013 | Identical |
NBN EN 61812-1 : 2011 | Identical |
NEN EN IEC 61812-1 : 2011 | Identical |
DIN EN 61812-1 : 2012 COR 1 2015 | Identical |
VDE 0435-2021 : 2012 COR 1 2015 | Identical |
BS EN 61812-1:2011 | Identical |
UNE-EN 61812-1:2012 | Identical |
EN 61812-1:2011 | Identical |
CEI EN 61812-1 : 2012 | Identical |
PN EN 61812-1 : 2013 | Identical |
NEN 11812-1 : 1997 | Identical |
I.S. EN 61812-1:2011 | Identical |
SAC GB/T 18908.1 : 2002 | Identical |
BS EN 62271-106:2011 | High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters |
EN 61000-6-5:2015/AC:2018-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT (IEC 61000-6-5:2015/COR1:2017) |
15/30310531 DC : 0 | BS EN 61709 ED 3.0 - ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION |
I.S. EN 61000-6-5:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT |
07/30169493 DC : 0 | BS IEC 60050-445 - INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 445: TIME RELAYS |
IEC 61709:2017 RLV | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
EN 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
BS EN 61709:2017 | Electric components. Reliability. Reference conditions for failure rates and stress models for conversion |
13/30281011 DC : 0 | BS EN 61000-6-5 ED.1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR POWER STATION AND SUBSTATION ENVIRONMENTS |
BS EN 60470:2001 | High-voltage alternating current contactors and contactor-based motor starters |
I.S. EN 61709:2017 | ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION |
UNE-EN 61000-6-5:2016 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment |
IEC 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
UNE-EN 62271-106:2012 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
08/30183795 DC : DRAFT JUNE 2008 | BS EN 62271-106 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND CONTACTOR-BASED MOTOR-STARTERS |
I.S. EN 62271-106:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND MOTOR-STARTERS (IEC 62271-106:2011 (EQV)) |
BS EN 61000-6-5:2015 | Electromagnetic compatibility (EMC) Generic standards. Immunity for equipment used in power station and substation environment |
EN 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
EN 60470:2000/corrigendum Jun. 2000 | HIGH-VOLTAGE ALTERNATING CURRENT CONTACTORS AND CONTACTOR-BASED MOTOR STARTERS |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
CAN/CSA-IEC 61000-6-5:18 | Electromagnetic compatibility (EMC) — Part 6-5: Generic standards — Immunity for equipment used in power station and substation environment (Adopted IEC 61000-6-5:2015, first edition, 2015-08) | Compatibilité électromagnétique (CEM) — Partie 6-5 : Normes génériques — Immunité pour les équipements utilisés dans les environnements de centrales électriques et de postes (norme IEC 61000-6-5:2015 adoptée, première édition, 2015-08) |
IEC 60947-5-4:2002 | Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 62314:2006 | Solid-state relays |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61810-1:2015 | Electromechanical elementary relays - Part 1: General and safety requirements |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60050-141:2004 | International Electrotechnical Vocabulary (IEV) - Part 141: Polyphase systems and circuits |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60050-444:2002 | International Electrotechnical Vocabulary (IEV) - Part 444: Elementary relays |
IEC 60730-2-7:2015 | Automatic electrical controls - Part 2-7: Particular requirements for timers and time switches |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60669-2-3:2006 | Switches for household and similar fixed electrical installations - Part 2-3: Particular requirements - Time-delay switches (TDS) |
IEC 60050-445:2010 | International Electrotechnical Vocabulary (IEV) - Part 445: Time relays |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.