IEC 61587-5:2013
Current
The latest, up-to-date edition.
Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
10-12-2013
IEC 61587-5:2013 specifies seismic test requirements for chassis, subracks, and plug-in units as defined in the IEC 60297 and IEC 60917 series. It applies in whole or in part, only to the mechanical structures of chassis, subracks, and plug-in units for electronic equipment, according to the IEC 60297 and IEC 60917 series, and does not apply to electronic components, equipment or systems within the mechanical structures. The object of this standard is to establish a level of physical integrity of chassis, subracks, and plug-in units according to IEC 60297 and IEC 60917 series that may provide a level of survivability that will preserve functionality during and after a seismic occurrence. It is intended to provide the user with a high level of confidence in the selection of an equipment practice to meet such needs. Since IEC 60297 and IEC 60917 series chassis, subracks, and plug-in units come in many sizes, weights and mechanical complexities, it is not possible to define a single minimum seismic test requirement for all weight categories. Therefore, overall mass categories are defined in this standard. However, the mass distribution inside a chassis and subrack is considered "application-specific" and herein defined as "intended use". Key words: chassis, subracks, plug-in units, seismic tests
Committee |
TC 48/SC 48D
|
DevelopmentNote |
Stability date: 2018. (11/2017)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61587-5 : 2014 | Identical |
NBN EN 61587-5 : 2014 | Identical |
NEN EN IEC 61587-5 : 2014 | Identical |
PN EN 61587-5 : 2014 | Identical |
VDE 0687-587-5 : 2014 | Identical |
DIN EN 61587-5 : 2014 | Identical |
BS EN 61587-5:2014 | Identical |
CEI EN 61587-5 : 2014 | Identical |
EN 61587-5:2014 | Identical |
PNE-FprEN 61587-5 | Identical |
UNE-EN 61587-5:2014 | Identical |
14/30295302 DC : 0 | BS EN 61587-1 ED. 4.0 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITIONS |
BS EN 60297-3-109:2016 | Mechanical structures for electrical and electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series Dimensions of chassis for embedded computing devices |
EN 60297-3-109 : 2016 | MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES |
I.S. EN 60297-3-108:2015 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-108: DIMENSIONS OF R-TYPE SUBRACKS AND PLUG-IN UNITS (IEC 60297-3-108:2014) |
BS EN 61587-1:2017 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 series Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
I.S. EN 60297-3-109:2016 | MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES |
CEI EN 61587-1 : 2012 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION |
I.S. EN 61587-1:2017 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION |
IEC 60297-3-109:2015 | Mechanical structures for electrical and electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-109: Dimensions of chassis for embedded computing devices |
EN 60297-3-109:2016 | MECHANICAL STRUCTURES FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING DEVICES |
IEC 61587-1:2016 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
14/30300716 DC : 0 | BS EN 60297-3-109 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 109: DIMENSIONS OF CHASSIS FOR EMBEDDED COMPUTING |
IEC 60297-3-108:2014 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-108: Dimensions of R-type subracks and plug-in units |
BS EN 60297-3-108:2015 | Mechanical structures for electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series Dimensions of R-type subracks and plug-in units |
EN 61587-1:2017 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
EN 60297-3-108:2015 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-108: Dimensions of R-type subracks and plug-in units |
IEC 60297-3-101:2004 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units |
ATIS 0600329 : 2014 | NETWORK EQUIPMENT - EARTHQUAKE RESISTANCE |
IEC 61587-2:2011 | Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks |
IEC 61587-3:2013 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks |
IEC 61587-1:2016 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
IEC 60068-2-57:2013 | Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60721-2-6:1990 | Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.