IEC 61557-16:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-08-2023
English - French
11-12-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Markings and operating instructions
6 Tests
Annex A (normative) - Measuring circuit MD
IEC 61557-16:2014 defines performance requirements for test and measurement equipment to determine the effectiveness of the protective measures of electrical measures for electrical equipment and/or medical electrical equipment described in IEC 62353. It is the intention of this standard to achieve comparable measuring results, additional safety for the testing person and negligible electrical stress for the unit under test. Keywords: leakage current, patient applied part
This publication is to be read in conjunction with IEC 61557-1:2007.
Committee |
TC 85
|
DevelopmentNote |
Stability date: 2019. To be read in conjunction with IEC 61557-1. (12/2014)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61557-16 : 2015 | Identical |
NBN EN 61557-16 : 2015 | Identical |
NEN EN IEC 61557-16 : 2015 | Identical |
PN EN 61557-16 : 2015 | Identical |
VDE 0413-16 : 2015 | Identical |
DIN EN 61557-16 : 2015 | Identical |
UNE-EN 61557-16:2015 | Identical |
BS EN 61557-16:2015 | Identical |
CEI EN 61557-16 : 2015 | Identical |
EN 61557-16:2015 | Identical |
SN EN 61557-16:2015 | Identical |
PNE-FprEN 61557-16:2013 | Identical |
BS EN 62353:2014 | Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment |
EN 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
IEC 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
UNE-EN 62353:2015 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
I.S. EN 62353:2014 | MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
IEC 61010-2-032:2012 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61557-10:2013 | Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures |
IEC 61010-2-030:2017 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits |
IEC 61557-1:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements |
IEC 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
IEC 61326-2-2:2012 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
IEC 61010-031:2015 RLV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test |
IEC 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 61557-13:2011 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.