IEC 61347-2-4:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
19-05-2011
English - French, Spanish, Castilian
13-10-2000
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
7.1 Mandatory markings
7.2 Information to be provided, if applicable
8 Protection against accidental contact with live
parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Pulse voltages
15 Abnormal conditions
15.1 Removal of lamp(s)
15.2 Lamp fails to start (cathodes intact
electrically)
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
Annex A (normative) Test to establish whether a conductive
part is a live part which may cause an
electric shock
Annex B (normative) Particular requirements for thermally
protected lamp controlgear
Annex C (normative) Particular requirements for electronic
lamp controlgear with means of
protection against overheating
Annex D (normative) Requirements for carrying out the heating
tests of thermally protected lamp
controlgear
Annex E (normative) Use of constant S other than 4 500 in tw
tests
Annex F (normative) Draught-proof enclosure
Annex G (normative) Explanation of the derivation of the
values of pulse voltages
Annex H (normative) tests
Table 1 - Pulse voltages
This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from transient and surge-free power sources, operated directly from batteries without charging equipment as used in leisure equipment, for example, caravans, etc.This first edition of IEC 61347-2-4, together with IEC 61347-1, cancels and replaces section three of the first edition of IEC 60924, published in 1990, and constitutes a minor revision.This standard shall be used in conjunction with IEC 61347-1. It was established on the basis of the first edition (2000) of that standard.
DevelopmentNote |
Supersedes IEC 60924 (03/2001) Also numbered as BS EN 61347-2-4 (04/2001)
|
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN EN IEC 61347-2-4 : 2001 | Identical |
PN EN 61347-2-4 : 2007 AC 2011 | Identical |
AS/NZS 61347.2.4:2002 | Identical |
SN EN 61347-2-4 : 2001 | Identical |
VDE 0712-34 : 2001 COR 2 2011 | Identical |
CEI EN 61347-2-4 : 2001 | Identical |
EN 61347-2-4:2001/corrigendum:2010 | Identical |
NF EN 61347-2-4 : 2001 | Identical |
UNE-EN 61347-2-4:2002 | Identical |
NF EN 60079-15 : 2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
11/30243697 DC : 0 | BS IEC 62718 - RAILWAY APPLICATIONS - ROLLING STOCK - D.C. SUPPLIED ELECTRONIC BALLASTS FOR LIGHTING FLUORESCENT LAMPS |
I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
BIS IS/IEC 60079-15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS |
CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
UL 1993:5ED 2017-01-27 | Self-Ballasted Lamps and Lamp Adapters |
C22.2 NO. 1993-17 | Self-ballasted lamps and lamp adapters (Trinational standard with NMX-J-578/1-ANCE and UL 1993) |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
GOST R 52350.15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
07/30168628 DC : 0 | BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
08/30186575 DC : DRAFT JULY 2008 | BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
CSA C22.2 No. 60079-15 : 2016 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV | DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.