IEC 61300-3-27:1997
Current
The latest, up-to-date edition.
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-27: Examinations and measurements - Measurement method for the hole location of a multiway connector plug
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
23-05-1997
FOREWORD
1 General
1.1 Scope and object
1.2 General description
2 Apparatus
3 Procedure
4 Details to be specified
IEC 61300-3-27:1997 is to measure the hole location of a multiway connector plug which has multiple fibre holes for arraying fibres and two guide holes for positioning two alignment pins. The following dimensions on the endface of the plug shall be accurately measured to satisfy the specified mechanical and optical performance of the connector:
– distance between two guide-hole centres L;
– position deviation of each fibre-hole centre Pi.
Committee |
TC 86/SC 86B
|
DevelopmentNote |
Also numbered as BS EN 61300-3.27 (11/2005) Stability Date: 2020. (10/2012)
|
DocumentType |
Standard
|
Pages |
11
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61300-3-27 : 1997 | Identical |
NEN EN IEC 61300-3-27 : 1997 | Identical |
I.S. EN 61300-3-27:1998 | Identical |
PN EN 61300-3-27 : 2002 | Identical |
SN EN 61300-3-27 : 1997 | Identical |
UNE-EN 61300-3-27:1998 | Identical |
CEI EN 61300-3-27 : 1997 | Identical |
EN 61300-3-27:1997 | Identical |
BS EN 61753-1-1:2001 | Fibre optic interconnecting devices and passive components performance standard. General and guidance Interconnecting devices (connectors) |
EN 50377-15-1:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 15-1: Type MPO with 12-fibre PPS ferrules terminated on IEC 60793-2 category A1a multimode fibre for 50/125 micron multimode fibre |
09/30209972 DC : 0 | BS EN 62005-9-3 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - RELIABILITY - PART 9-3: RELIABILITY QUALIFICATION FOR 1-ROW MULTI-FIBRE RECTANGULAR FERRULE ANGLED PC OPTIC CONNECTOR SETS - SINGLE MODE, CATEGORY C |
17/30353664 DC : 0 | BS EN 50377-18-1 - CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 18-1: TYPE 4+4X10.3125 GB/S MPO (QFSP) TRANSCEIVER MATED WITH AN MPO CONNECTOR EQUIPPED WITH 12 FIBRE PPS FERRULES TERMINATED ON EN 60793-2-10 CATEGORY A1A.3A OR A1A.3B 50/125 MICRON MULTIMODE FIBRE |
00/242786 DC : DRAFT JUN 2000 | IEC 61753-1-1 - FIBRE OPTIC PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 1-1: GENERAL AND GUIDANCE |
CEI EN 50377-15-1 : 2012 | CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 15-1: TYPE MPO WITH 12-FIBRE PPS FERRULES TERMINATED ON IEC 60793-2 CATEGORY A1A MULTIMODE FIBRE FOR 50/125 MICRON MULTIMODE FIBRE |
IEC 62005-1:2001 | Reliability of fibre optic interconnecting devices and passive components - Part 1: Introductory guide and definitions |
IEC 61753-2-3:2001 | Fibre optic interconnecting devices and passive components performance standard - Part 2-3: Non-connectorised single-mode 1xN and 2xN non-wavelength-selective branching devices for Category U - Uncontrolled environment |
I.S. EN 50377-15-1:2011 | CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 15-1: TYPE MPO WITH 12-FIBRE PPS FERRULES TERMINATED ON IEC 60793-2 CATEGORY A1A MULTIMODE FIBRE FOR 50/125 MICRON MULTIMODE FIBRE |
08/30185105 DC : DRAFT JULY 2008 | BS EN 50377-15-1 - CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 15-1: TYPE MPO WITH PPS FERRULES TERMINATED ON IEC 60793-2 CATEGORY A1A MULTIMODE FIBRE FOR 50/125 MICRON MULTIMODE FIBRE |
BS EN 50377-15-1:2011 | Connector sets and interconnect components to be used in optical fibre communication systems. Product specifications Type MPO with 12-fibre PPS ferrules terminated on IEC 60793-2 category A1a multimode fibre for 50/125 micron multimode fibre |
EN 61753-1-1:2001 | Fibre optic interconnecting devices and passive components performance standard - Part 1-1: General and guidance - Interconnecting devices (connectors) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.