IEC 61000-4-19:2014
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
07-05-2014
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines:
- test waveforms;
- range of test levels;
- test equipment;
- test setup;
- test procedures;
- and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC
Committee |
TC 77/SC 77A
|
DevelopmentNote |
Stability Date: 2018. (11/2017)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61000-4-19 : 2014 | Identical |
NBN EN 61000-4-19 : 2014 | Identical |
NEN EN IEC 61000-4-19 : 2014 | Identical |
PN EN 61000-4-19 : 2014 | Identical |
VDE 0847-4-19 : 2015 | Identical |
DIN EN 61000-4-19 : 2015 | Identical |
UNE-EN 61000-4-19:2015 | Identical |
BS EN 61000-4-19:2014 | Identical |
CEI EN 61000-4-19 : 2015 | Identical |
EN 61000-4-19:2014 | Identical |
SN EN 61000-4-19:2014 | Identical |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
UNE-EN 61000-4-30:2015 | Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods |
IEC 61000-4-16:2015 RLV | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
S.R. CLC/TR 50669:2017 | INVESTIGATION RESULTS ON ELECTROMAGNETIC INTERFERENCE IN THE FREQUENCY RANGE BELOW 150 KHZ |
I.S. EN 61000-4-30:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS |
OIML D 11 : 2013 | GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN 61000-6-5:2015/AC:2018-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT (IEC 61000-6-5:2015/COR1:2017) |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
PD IEC/TS 62578:2015 | Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
CAN/CSA-IEC 61000-4-16:17 | Electromagnetic compatibility (EMC) — Part 4-16: Testing and measurement techniques — Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz (Adopted IEC 61000-4-16:2015, second edition, 2015-12) | Compatibilité électromagnétique (CEM) — Partie 4-16 : Techniques d’essai et de mesure — Essai d’immunité aux perturbations conduites en mode commun dans la plage de fréquences de 0 Hz à 150 kHz (norme IEC 61000-4-16:2015 adoptée, deuxième édition, 2015:12) |
I.S. EN 61000-1-2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 1-2: GENERAL - METHODOLOGY FOR THE ACHIEVEMENT OF FUNCTIONAL SAFETY OF ELECTRICAL AND ELECTRONIC SYSTEMS INCLUDING EQUIPMENT WITH REGARD TO ELECTROMAGNETIC PHENOMENA |
IEC 61000-6-1:2016 RLV | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 61000-4-16:2015 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
UNE-EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
PD IEC/TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) Environment. Description and classification of electromagnetic environments |
I.S. EN 61000-6-5:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT |
S.R. CLC/TR 50627:2015 | STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ |
CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
BS EN 61000-1-2:2016 | Electromagnetic compatibility (EMC) General. Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
PD CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
PD CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
IEC TS 62578:2015 | Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
IEC TR 61000-4-1:2016 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
UNE-EN 61000-6-5:2016 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment |
IEC 61000-4-30:2015 RLV | Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods |
IEC 61000-1-2:2016 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
BS EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
BS EN 61000-6-5:2015 | Electromagnetic compatibility (EMC) Generic standards. Immunity for equipment used in power station and substation environment |
BS EN 61000-4-30:2015 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Power quality measurement methods |
IEC 61000-6-2:2016 RLV | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
I.S. EN 61000-2-2:2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
I.S. EN 61000-4-16:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-16: TESTING AND MEASUREMENT TECHNIQUES - TEST FOR IMMUNITY TO CONDUCTED, COMMON MODE DISTURBANCES IN THE FREQUENCY RANGE 0 HZ TO 150 KHZ |
CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
IEC TR 61000-2-5:2017 RLV | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
EN 61000-1-2:2016 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
CAN/CSA-IEC 61000-6-5:18 | Electromagnetic compatibility (EMC) — Part 6-5: Generic standards — Immunity for equipment used in power station and substation environment (Adopted IEC 61000-6-5:2015, first edition, 2015-08) | Compatibilité électromagnétique (CEM) — Partie 6-5 : Normes génériques — Immunité pour les équipements utilisés dans les environnements de centrales électriques et de postes (norme IEC 61000-6-5:2015 adoptée, première édition, 2015-08) |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
IEC TS 62578:2015 | Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
IEC 61000-3-8:1997 | Electromagnetic compatibility (EMC) - Part 3: Limits - Section 8: Signalling on low-voltage electrical installations - Emission levels, frequency bands and electromagnetic disturbance levels |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
CLC/TR 50579:2012 | ELECTRICITY METERING EQUIPMENT (A.C.) - SEVERITY LEVELS, IMMUNITY REQUIREMENTS AND TEST METHODS FOR CONDUCTED DISTURBANCES IN THE FREQUENCY RANGE 2 KHZ - 150 KHZ |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.