FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 General conditions for tests
6 Electrical rating
7 Classification
8 Marking
9 Protection against electric shock
10 Terminals
11 Construction
12 Resistance to dust and moisture
13 Insulation resistance and electric strength
14 Endurance
15 Mechanical strength
16 Screws, current-carrying parts and connections
17 Creepage distances and clearances
18 Resistance to heat, fire and tracking
19 Resistance to excessive residual stresses (season
cracking) and to rusting
Annex A (normative) - Examples of lampholders
covered by IEC 60400
Annex B (normative) - Season cracking/corrosion test
Annex C (informative) - Protection against electric
shock - Explanatory details for the installation
of lampholders according to 9.2
Annex D (informative) - Clauses containing new or
more stringent requirements with respect to the
previous edition
Bibliography
IEC 60400:2017 states the technical and dimensional requirements for lampholders for tubular fluorescent lamps and for starterholders, and the methods of test to be used in determining the safety and the fit of the lamps in the lampholders and the starters in the starterholders.
This eighth edition cancels and replaces the seventh edition published in 2008, Amendment 1:2011 and Amendment 2:2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- alignment with ISO/IEC drafting rules;
- renumbering of clauses, tables and figures.
This bilingual version (2017-12) corresponds to the monolingual English version, published in 2017-06.
The French version of this standard has not been voted upon.
Committee |
TC 34/SC 34B
|
DevelopmentNote |
Stability Date: 2019. (06/2017) New child AMD 1 2020 is added
|
DocumentType |
Standard
|
Pages |
113
|
ProductNote |
New child AMD 1 2020 is added
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 60400:2017 | Identical |
BS EN 60400:2017 | Identical |
NEN EN IEC 60400 : 2017 | Identical |
CEI EN 60400:2020 | Identical |
UNE 20394:1990 | Identical |
DIN EN 60400 : 2018 | Identical |
VDE 0616-3 : 2018 | Identical |
GOST R IEC 60400 : 1999 | Identical |
GOST IEC 60400 : 2011 | Identical |
UNE-EN 60400:2011 | Identical |
UNE-EN 60400:2017 | Identical |
BS 6702:1991 | Similar to |
NBN EN 60400 : 2009 AMD 2 2014 | Identical |
PN EN 60400 : 2017 | Identical |
NF EN 60400 : 2008 AMD 2 2014 | Identical |
SN EN 60400 : 2017 | Identical |
PNE-FprEN 60400:2016 | Identical |
07/30168995 DC : 0 | BS EN 60399 AMD 1 - BARREL THREAD FOR LAMPHOLDERS WITH SHADE HOLDER RING |
CSA C22.2 No. 62560 : 2016 | SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
NF EN 60079-15 : 2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
CSA E60079.15 : 2002 : R2011 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS WITH TYPE OF PROTECTION "n" |
I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
I.S. EN 62560:2012/A11:2019 | SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
IEC 62931:2017 | GX16t-5 capped tubular LED lamp - Safety specifications |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
CSA E60335.2.27 : 2001 | SAFETY OF HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - PART 2: PARTICULAR REQUIREMENTS FOR APPLIANCES FOR SKIN EXPOSURE TO ULTRAVIOLET AND INFRARED RADIATION |
BS IEC 60092-306:2009 | Electrical installations in ships Equipment. Luminaires and lighting accessories |
04/30113660 DC : DRAFT MAY 2004 | IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E' |
DIN 49646-7:1985-04 | IEC LAMPHOLDER GAUGES; GAUGE FOR MOUNTED LAMPHOLDERS G13 FOR TESTING CONTACT |
DIN 49646-6:1985-04 | IEC LAMPHOLDER GAUGES; GAUGE FOR MOUNTED LAMPHOLDERS G5 FOR TESTING CONTACT |
CAN/CSA-E155-98 (R2017) | Glow-Starters for Fluorescent Lamps - Includes Amendment 1 (Adopted IEC 155:1993 with modifications) / Interrupteurs d\'amorçage à lueur pour lampes à fluorescence (starters) (norme CEI 155:1993 adoptée avec modifications) |
BS EN 62560:2012+A11:2019 | Self-ballasted LED-lamps for general lighting services by voltage > 50 V. Safety specifications |
UNE-IEC 60092-306:2010 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
I.S. EN 62931:2017 | GX16T-5 CAPPED TUBULAR LED LAMP - SAFETY SPECIFICATIONS |
I.S. EN 60399:2004 | BARREL THREAD FOR LAMPHOLDERS WITH SHADE HOLDER RING |
BS EN 50019:2000 | Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\' |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
BIS IS/IEC 60079-15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS |
ISA 60079-7 : 2008 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E" |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
ANSI C81.64:2005 (R2014) | American National Standard—Guidelines and General Information for Electrical Lamp Bases, Lampholders and Gauges |
DIN 49646-8:1985-04 | IEC LAMPHOLDER GAUGES; " GO " GAUGE FOR LAMPHOLDERS G5 |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
BS EN 60155:1995 | Glow-starters for fluorescent lamps |
DIN 49646-5:1985-04 | IEC LAMPHOLDER GAUGES; " GO " GAUGES FOR THE MOUNTING DISTANCES OF A COMBINED PAIR OF LAMPHOLDERS G13 |
NF EN 60155 : 1996 AMD 2 2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
CSA E155 : 1998 : R2012 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
EN 62931:2017 | GX16t-5 capped tubular led lamp - Safety specifications |
UL 1993:5ED 2017-01-27 | Self-Ballasted Lamps and Lamp Adapters |
C22.2 NO. 1993-17 | Self-ballasted lamps and lamp adapters (Trinational standard with NMX-J-578/1-ANCE and UL 1993) |
CSA E598.1 : 2002 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
09/30206120 DC : 0 | BS EN 60061-1 - LAMP CAPS AND HOLDERS TOGETHER WITH GAUGES FOR THE CONTROL OF INTERCHANGEABILITY AND SAFETY - PART 1: LAMP CAPS (AMENDMENT 44); PART 2: LAMPHOLDERS (AMENDMENT 41); PART 3: GAUGES (AMENDMENT 42); PART 4: GUIDELINES AND GENERAL INFORMATION (AMENDMENT 13) |
08/30186163 DC : DRAFT JULY 2008 | BS IEC 60092-306 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 306: EQUIPMENT - LUMINAIRES AND LIGHTING ACCESSORIES |
BS 2011-2.1Ef:1992 | Environmental testing. Tests Test Ef. Impact, pendulum hammer |
BS EN 60399 : 2004 | BARREL THREAD FOR LAMPHOLDERS WITH SHADE HOLDER RING |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 60061-4:1992+A16:2018 | Lamp caps and holders together with gauges for the control of interchangeability and safety Guidelines and general information |
I.S. EN 60838-2-3:2017 | MISCELLANEOUS LAMPHOLDERS - PART 2-3: PARTICULAR REQUIREMENTS - LAMPHOLDERS FOR DOUBLE-CAPPED LINEAR LED LAMPS |
GOST R 52350.15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS |
UNE-EN 60598-1:2015 | Luminaires - Part 1: General requirements and tests |
IEC 62560:2011+AMD1:2015 CSV | Self-ballasted LED-lamps for general lighting services by voltage >50 V - Safety specifications |
I.S. EN 60155:1996 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60838-2-3:2016 | Miscellaneous lampholders - Part 2-3: Particular requirements - Lampholders for double-capped linear LED lamps |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60399:2004+AMD1:2008 CSV | Barrel thread for lampholders with shade holder ring |
UNE-EN 62560:2013 | Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications |
UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
CEI EN 62931 : 1ED 2017 | GX16T-5 CAPPED TUBULAR LED LAMP - SAFETY SPECIFICATIONS |
07/30168628 DC : 0 | BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
BS EN 62931:2017 | GX16t-5 capped tubular led lamp. Safety specifications |
DIN 49646-9 : 1985 | IEC LAMPHOLDER GAUGES; " GO " GAUGE FOR LAMPHOLDERS G13 |
BS EN 60838-2-3:2017 | Miscellaneous lampholders Particular requirements. Lampholders for double-capped linear LED lamps |
DIN 49646-4:1985-04 | IEC LAMPHOLDER GAUGES; " GO " GAUGES FOR THE MOUNTING DISTANCES OF A COMBINED PAIR OF LAMPHOLDERS G5 |
I.S. EN 60061-4:1993 | LAMP CAPS AND HOLDERS TOGETHER WITH GAUGES FOR THE CONTROL OF INTERCHANGEABILITY AND SAFETY - PART 4: GUIDELINES AND GENERAL INFORMATION |
08/30186575 DC : DRAFT JULY 2008 | BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
CSA E60079.7 : 2003 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E" |
CSA E60079.15 : 2002 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS WITH TYPE OF PROTECTION "n" |
BIS IS/IEC 60079-7 : 2006 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
CSA E155:1998 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
I.S. EN 50019:2001 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
IEC 60092-306:2009 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
EN 60061-4:1992/A16:2018 | LAMP CAPS AND HOLDERS TOGETHER WITH GAUGES FOR THE CONTROL OF INTERCHANGEABILITY AND SAFETY - PART 4: GUIDELINES AND GENERAL INFORMATION (IEC 60061-4:1990/A16:2018) |
EN 60838-2-3:2017 | Miscellaneous lampholders - Part 2-3: Particular requirements - Lampholders for double-capped linear LED lamps |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 60399:2004/A1:2008 | BARREL THREAD FOR LAMPHOLDERS WITH SHADE HOLDER RING |
EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
CSA C22.2 No. 60079-15 : 2016 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 60061-4:1996 | LAMP CAPS AND HOLDERS TOGETHER WITH GAUGES FOR THE CONTROL OF INTERCHAngeability and safety. Part 4: Guidelines and general information. |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60838-1:2016+AMD1:2017 CSV | Miscellaneous lampholders - Part 1: General requirements and tests |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60399:2004+AMD1:2008 CSV | Barrel thread for lampholders with shade holder ring |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
IEC 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.