IEC 60364-7-712:2017 RLV
Current
The latest, up-to-date edition.
Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
10-04-2017
FOREWORD
INTRODUCTION
712 Solar photovoltaic (PV) power supply installations
712.1 Scope
712.2 Normative references
712.3 Terms and definitions
712.31 Purposes, supplies and structure
712.4 Protection for safety
712.41 Protection against electric shock
712.410 Introduction
712.412 Protective measure: double or reinforced
insulation
712.414 Protective measure: extra-low-voltage provided
by SELV and PELV
712.42 Protection against thermal effects
712.421 Protection against fire caused by electrical
equipment
712.43 Protection against overcurrent
712.432 Nature of protective devices
712.433 Protection against overload current
712.434 Protection against short-circuit currents
712.44 Protection against voltage disturbances and
electromagnetic disturbances
712.443 Protection against transient overvoltages of
atmospheric origin or due to switching
712.444 Measures against electromagnetic influences
712.5 Selection and erection of electrical equipment
712.51 Common rules
712.511 Compliance with standards
712.512 Operational conditions and external influences
712.513 Accessibility
712.514 Identification
712.515 Prevention of mutual detrimental influence
712.52 Wiring systems
712.521 Types of wiring systems
712.522 Selection and erection of wiring systems in
relation to external influences
712.523 Current-carrying capacities
712.524 Cross-sectional areas of conductors
712.525 Voltage drop in consumers installations
712.526 Electrical connections
712.527 Selection and erection of wiring systems to
minimize spread of fire
712.528 Proximity of wiring systems to other services
712.529 Selection and erection of wiring systems in
relation to maintainability, including cleaning
712.53 Isolation, switching and control
712.531 Devices for protection against indirect contact
(fault protection) by automatic disconnection of
supply
712.532 Devices for protection against thermal effects
712.533 Devices for protection against overcurrent
712.534 Devices for protection against transient
overvoltages
712.536 Isolation and switching
712.54 Earthing arrangements and protective
conductors
712.542 Earthing arrangements
712.55 Other equipment
712.6 Inspection and testing
Annex A (informative) - PV installation information
Annex B (normative) - Calculation of U[OC MAX]
and I[SC MAX]
Annex C (informative) - Examples of signs
Annex D (informative) - Blocking diode
Annex E (informative) - Arc fault detection and
interruption in PV arrays
Annex F (informative) - List of notes concerning
certain countries
Bibliography
IEC 60364-7-712:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60364-7-712:2017 applies to the electrical installation of PV systems intended to supply all or part of an installation. The equipment of a PV installation, like any other item of equipment, is dealt with only so far as its selection and application in the installation is concerned. This new edition includes significant revisions and extensions, taking into account experience gained in the construction and operation of PV installations, and developments made in technology, since the first edition of this standard was published.
Committee |
TC 64
|
DevelopmentNote |
Stability Date: 2020. (04/2017)
|
DocumentType |
Redline
|
Pages |
207
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
UL 1699:3ED 2017-05-03 | Arc-Fault Circuit-Interrupters |
IEC 62423:2009 | Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 62246-1:2015 | Reed switches - Part 1: Generic specification |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60269-6:2010 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61730-2:2016 | Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC TS 61836:2007 | Solar photovoltaic energy systems - Terms, definitions and symbols |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 61829:2015 | Photovoltaic (PV) array - On-site measurement of current-voltage characteristics |
IEC 60904-2:2015 RLV | Photovoltaic devices - Part 2: Requirements for photovoltaic reference devices |
IEC 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 62852:2014 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
IEC 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60898-2:2016 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for AC and DC operation |
IEC 62109-2:2011 | Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 62109-1:2010 | Safety of power converters for use in photovoltaic power systems - Part 1: General requirements |
IEC 61277:1995 | Terrestrial photovoltaic (PV) power generating systems - General and guide |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
IEC 61439-2:2011 | Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.