IEC 60364-5-51:2005
Current
The latest, up-to-date edition.
Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, English, French
14-04-2005
FOREWORD
510 Introduction
511 Compliance with standards
512 Operational conditions and external influences
513 Accessibility
514 Identification
515 Prevention of mutual detrimental influence
516 Measures related to protective conductor currents
Annex A (informative) - Concise list of external influences
Annex B (Annex B of IEC 60364-3) (informative) - Interdependence
of air temperature, relative air humidity and absolute
air humidity
Annex C (Annex C of IEC 60364-3) (normative) - Classification
of mechanical conditions
Annex D (Annex D of IEC 60364-3) (normative) - Classification
of macro-environments
Annex E (informative) - Permissible protective conductor currents
for equipment
Annex F (informative) - IEC 60364 - Parts 1 to 6: Restructuring
Bibliography
Deals with the selection of equipment and its erection. It provides common rules for compliance with measures of protection for safety, requirements for proper functioning for intended use of the installation, and requirements appropriate to the external influences foreseen.The main changes with respect to the previous edition are listed below:- corrections of misprints in Table 51 based on Table 321 derived from the old Part 3;- introduction of a new Clause 516 dealing with measures for mitigation of protective conductor currents;- introduction of an informative Annex B extracted from IEC 61140 in Annex E of this standard. Annex B of IEC 61140 deals with protective conductor currents.
DevelopmentNote |
Supersedes IEC 60364-3 (01/2002) Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
89
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS C 60364-5-51:2010 | Identical |
DIN VDE 0100-510 : 2014-10 | Identical |
VDE 0100-510 : 2014-10 | Identical |
I.S. HD 60364-5-51:2009 | Identical |
HD 60364-5-51:2009/A12:2017 | Identical |
NEN HD 60364-5-51 : 2009 AMD 12 2017 | Identical |
CEI 64-8/5:2021 | Identical |
I.S. HD 384.5.51:1998 | Identical |
HD 384.5.51 : 200S2 | Identical |
I.S. EN 60664-5:2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM |
UNE-HD 60364-4-442:2013 | Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage system and due to faults in the low voltage system |
UNE-HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
BS EN 50085-1 : 2005 | CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
BS EN 61643-312:2013 | Components for low-voltage surge protective devices Selection and application principles for gas discharge tubes |
PD IEC/TR 61916:2017 | Electrical accessories. Harmonization of general rules |
S.R. HD 60364-7-705:2007 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
07/30161792 DC : 0 | BS EN 61535 - INSTALLATION OF COUPLERS INTENDED FOR PERMANENT CONNECTIONS IN FIXED INSTALLATIONS |
BS EN 60664-5:2003 | Insulation coordination for equipment within low-voltage systems A comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
10/30184592 DC : 0 | BS EN 61643-311 ED 2.0 - COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 311: TEST SPECIFICATION FOR GAS DISCHARGE TUBES |
PREN 474-1 : DRAFT 2017 | EARTH-MOVING MACHINERY - SAFETY - PART 1: GENERAL REQUIREMENTS |
10/30217306 DC : DRAFT FEB 2010 | BS IEC 60364-7-714 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-714: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXTERNAL LIGHTING INSTALLATIONS |
07/30162831 DC : 0 | BS EN 13193 - SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES |
S.R. HD 60364-4-42:2011 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
I.S. EN 50521:2008 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
I.S. EN 61643-311:2013 | COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 311: PERFORMANCE REQUIREMENTS AND TEST CIRCUITS FOR GAS DISCHARGE TUBES (GDT) (IEC 61643-311:2013 (EQV)) |
BS EN 50539-11 : 2013 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS |
BS EN 61730-1 : 2007 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
I.S. HD 60364-6:2007 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION |
IEC TR 63040:2016 | Guidance on clearances and creepage distances in particular for distances equal to or less than 2 mm - Test results of research on influencing parameters |
IEC 60364-7-722:2015 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
CSA C22.2 No. 61730-1 : 2011 : INC : AMD 1 : 2013 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
I.S. HD 60364-7-705:2007 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES (IEC 60364-7-705:2006 (MOD)) |
UNE-HD 60364-7-714:2013 | Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations |
BS 3535-1:1990 | Isolating transformers and safety isolating transformers General requirements |
17/30293139 DC : DRAFT SEP 2017 | BS IEC 60364-8-2 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 8-2: SMART LOW-VOLTAGE ELECTRICAL INSTALLATIONS |
CLC/TS 61643-22:2016 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
EN 62626-1:2014 | Low-voltage switchgear and controlgear enclosed equipment - Part 1: Enclosed switch-disconnectors outside the scope of IEC 60947-3 to provide isolation during repair and maintenance work |
EN 50539-11 : 2013 AMD 1 2014 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS |
EN 50085-1 : 2005 AMD 1 2013 | CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
HD 60364-7-714:2012 | Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
HD 60364-5-52:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 50425:2008 | Switches for household and similar fixed electrical installations - Collateral standard - Fireman's switches for exterior and interior signs and luminaires |
I.S. EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
NF EN 60664-5 : 2008 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM |
PD CLC/TS 61643-22:2016 | Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles |
14/30298271 DC : 0 | BS EN 60364-7-722 ED 1.0 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLY OF ELECTRIC VEHICLES |
I.S. EN 62626-1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ENCLOSED EQUIPMENT - PART 1: ENCLOSED SWITCH-DISCONNECTORS OUTSIDE THE SCOPE OF IEC 60947-3 TO PROVIDE ISOLATION DURING REPAIR AND MAINTENANCE WORK |
BS 6751:1986 | Guide for protection of machine tools intended for use in extreme environmental conditions |
10/30202620 DC : 0 | BS EN 62626-1 - LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR - ENCLOSED SWITCH FOR VARIOUS APPLICATIONS TO PROVIDE ISOLATION OF ELECTRICAL EQUIPMENT DURING REPAIR AND MAINTENANCE WORK |
04/30121837 DC : DRAFT SEP 2004 | EN 50085-1 - CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
06/30156742 DC : DRAFT OCT 2006 | |
S.R. HD 60364-6:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION |
IEC TR 61200-52:2013 | Electrical installation guide - Part 52: Selection and erection of electrical equipment - Wiring systems |
IEC TR 61200-704:1996 | Electrical installation guide - Part 704: Construction and demolition site installations |
I.S. EN 60669-2-6:2012 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-6: PARTICULAR REQUIREMENTS - FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES (IEC 60669-2-6:2012 (MOD)) |
I.S. EN 50539-11:2013 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS |
I.S. HD 60364-7-718:2013 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES (IEC 60364-7-718:2011 (EQV)) |
I.S. EN 62852:2015 | CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
PD IEC TR 63040:2016 | Guidance on clearances and creepage distances in particular for distances equal to or less than 2 mm. Test results of research on influencing parameters |
I.S. HD 60364-7-721:2009 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
CSA C22.2 No. 61730-1 : 2011 : INC : UPD 1 : 2013 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
UNE-EN 62626-1:2014 | Low-voltage switchgear and controlgear enclosed equipment - Part 1: Enclosed switch-disconnectors outside the scope of IEC 60947-3 to provide isolation during repair and maintenance work |
IEC 61643-22:2015 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
UNE-HD 60364-4-444:2013 | Low-voltage electrical installations -- Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
03/523674 DC : DRAFT APR 2003 | IEC 60364-1 ED. 5.0 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
UNE-EN 81-20:2017 | Safety rules for the construction and installation of lifts - Lifts for the transport of persons and goods - Part 20: Passenger and goods passenger lifts |
BS IEC 62852 : 2014 | CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
UNE-EN 15869-2:2011 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
DIN EN 15869-2:2010-06 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
DIN V VDE V 0800-2-548 : 1999 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SECTION 548: EARTHING ARRANGEMENTS AND EQUIPOTENTIAL BONDING FOR INFORMATION TECHNOLOGY INSTALLATIONS |
VDI 3551:2011-01 | Electromagnetic compatibility (EMC) in building services |
VDE 0804 : 1989 AMD 1 1992 | TELECOMMUNICATIONS; ADDITIONAL REQUIREMENTS FOR CONSTRUCTION AND TESTING OF APPARATUS |
CSA C22.2 No. 61730-1 : 2011 : INC : AMD 2 : 2015 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
11/30251717 DC : 0 | BS EN 81-20 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - LIFTS FOR THE TRANSPORT OF PERSONS AND GOODS - PART 20: PASSENGER AND GOODS PASSENGER LIFTS |
BS EN 61643-311:2013 | Components for low-voltage surge protective devices Performance requirements and test circuits for gas discharge tubes (GDT) |
CEI EN 60664-5 : 2008 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM |
BS EN 50425:2008 | Switches for household and similar fixed electrical installations. Collateral standard. Fireman\'s switches for exterior and interior signs and luminaires |
BS EN 62626-1:2014 | Low-voltage switchgear and controlgear enclosed equipment Enclosed switch-disconnectors outside the scope of IEC 60947-3 to provide isolation during repair and maintenance work |
12/30249498 DC : 0 | BS EN 60364-7-713 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-713: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - FURNITURE |
I.S. HD 50573-5-57:2014 | CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL |
11/30207763 DC : 0 | BS EN 60669-2-6 - SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-6: FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES |
HD 60364-7-718:2013/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES |
09/30210369 DC : DRAFT SEP 2009 | IEC 61643-11 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PERFORMANCE REQUIREMENTS AND TESTING METHODS |
16/30301665 DC : 0 | BS EN 61439-2 ED3.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: POWER SWITCHGEAR AND CONTROLGEAR ASSEMBLIES |
I.S. HD 60364-4-42:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
10/30184605 DC : 0 | BS EN 61643-313 ED 1.0 - COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 313: SELECTION AND APPLICATION PRINCIPLES FOR GAS DISCHARGE TUBES (GDT) |
UNE-EN 55011:2011 | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CSA C22.4 No. 1 : 2009(R2018) | OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
HD 60364-7-705:2007/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES |
IEC TR 61916:2017 | Electrical accessories - Harmonization of general rules |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
CEI EN 61643-11 : 2014 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS |
I.S. EN 61643-11:2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TESTS METHODS |
I.S. HD 60364-5-52:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
BS EN 55011 : 2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
BS EN 61643-21 : 2001 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS |
I.S. HD 60364-7-714:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-714: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXTERNAL LIGHTING INSTALLATIONS (IEC 60364-7-714:2011 (EQV)) |
S.R. CLC/TS 61643-22:2016 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES |
IEC 60364-7-718:2011 | Low-voltage electrical installations - Part 7-718: Requirements for special installations or locations - Communal facilities and workplaces |
IEC 61024-1-2:1998 | Protection of structures against lightning - Part 1-2: General principles - Guide B - Design, installation, maintenance and inspection of lightning protection systems |
IEC 62986:2017 | Plugs, socket-outlets and couplers with arcuate contacts |
IEC 61991:2000 | Railway applications - Rolling stock - Protective provisions against electrical hazards |
UNI EN 81-20 : 2014 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - LIFTS FOR THE TRANSPORT OF PERSONS AND GOODS - PART 20: PASSENGER AND GOODS PASSENGER LIFTS |
04/30112692 DC : DRAFT APR 2004 | IEC 60364 ED.1 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 6: VERIFICATION |
IEC 61643-311:2013 | Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT) |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
UNE-EN 50521:2010 | Connectors for photovoltaic systems - Safety requirements and tests |
UNE-HD 60364-5-53:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear |
UNI EN 15869-2 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS EN 60669-2-6:2012 | Switches for household and similar fixed electrical installations Particular requirements. Fireman\'s switches for exterior and interior signs and luminaires |
CSA C22.4 PACKAGE : 2009 | CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS |
IEC 60364-7-711:2018 | Low-voltage electrical installations - Part 7-711: Requirements for special installations or locations - Exhibitions, shows and stands |
I.S. HD 384.6.61 S2:2003 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 6-61: VERIFICATION - INITIAL VERIFICATION |
01/219357 DC : DRAFT MAY 2001 | IEC 60364-4-41 ED.5.0 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
14/30310464 DC : 0 | BS EN 61643-31 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 31: REQUIREMENTS AND TEST METHODS FOR SPDS FOR PHOTOVOLTAIC INSTALLATIONS |
IEC 61643-11:2011 | Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods |
I.S. EN 55011:2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
I.S. EN 15869-2:2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
CSA ISO/IEC 18010 :2004 | INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING |
S.R. HD 60364-5-53:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
S.R. HD 60364-5-54:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
CEI EN 55011 : 2017 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
S.R. HD 60364-5-52:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
I.S. EN 61643-312:2013 | COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 312: SELECTION AND APPLICATION PRINCIPLES FOR GAS DISCHARGE TUBES (IEC 61643-312:2013 (EQV) + CORRIGENDUM JUL. 2013 (EQV)) |
I.S. EN 61643-21:2001 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000 (EQV) + CORRIGENDUM MAR. 2001 (EQV)) |
BS EN ISO 11197:2009 | Medical supply units |
I.S. HD 60364-4-444:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
IEC 60364-4-44:2007+AMD1:2015+AMD2:2018 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC TR 62350:2006 | Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
BS EN 15869-2:2010 | Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz Onshore unit, safety requirements |
IEC 60669-2-6:2012 | Switches for household and similar fixed electrical installations - Part 2-6: Particular requirements - Fireman's switches for exterior and interior signs and luminaires |
EN 62852:2015 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
97/200935 DC : DRAFT JAN 1997 | IEC 60364 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - REVISION OF CHAPTER 54: EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
UNE-HD 60364-6:2017 | Low-voltage electrical installations - Part 6: Verification |
BS EN 81-20:2014 | Safety rules for the construction and installation of lifts. Lifts for the transport of persons and goods Passenger and goods passenger lifts |
BS EN 62852:2015 | Connectors for DC-application in photovoltaic systems. Safety requirements and tests |
BS EN 50521 : 2009 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
08/30179116 DC : DRAFT MAR 2008 | BS EN 50521 - CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
16/30301661 DC : 0 | BS EN 61439-1 ED3.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
UNE-HD 60364-7-721:2011 | Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans |
EN 45510-2-9 : 2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
EN 15869-2:2010 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
09/19987837 DC : 0 | BS IEC 60364-7-713 ED2 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-713: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - FURNITURE |
BS IEC 60533:2015 | Electrical and electronic installations in ships. Electromagnetic compatibility (EMC). Ships with a metallic hull |
10/30184598 DC : 0 | BS EN 61643-312 ED 1.0 - COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 312: PERFORMANCE SPECIFICATION FOR GAS DISCHARGE TUBES (GDT) |
PD IEC/TR 62350:2006 | Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use |
12/30263969 DC : 0 | BS EN 55011 - GENERAL MAINTENANCE FOR CISPR 11 ED.5.1 |
NF EN 61730-1 : 2007 AMD 11 2015 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
BS EN 61643-11 : 2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS |
BS 61535:2006 | Installation couplers intended for permanent connection in fixed installations |
IEC 62440:2008 | Electric cables with a rated voltage not exceeding 450/750 V - Guide to use |
HD 60364-7-721:2009/corrigendum:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
NF EN 50425 : 2008 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
S.R. HD 60364-7-718:2013 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES |
CSA ISO/IEC 18010 : 2004 : INC : AMD 1 : 2006 : R2012 | INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING |
CEI EN 60669-2-6 : 2012 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-6: PARTICULAR REQUIREMENTS - FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES |
HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
I.S. EN 61730-1:2007 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
I.S. EN 50425:2008 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - FIREMAN'S SWITCHES FOR EXTERIOR AND INTERIOR SIGNS AND LUMINAIRES |
S.R. HD 60364-4-443:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-44: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES - CLAUSE 443: PROTECTION AGAINST TRANSIENT OVERVOLTAGES OF ATMOSPHERIC ORIGIN OR DUE TO SWITCHING |
I.S. EN 81-20:2014 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - LIFTS FOR THE TRANSPORT OF PERSONS AND GOODS - PART 20: PASSENGER AND GOODS PASSENGER LIFTS |
I.S. HD 60364-5-54:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
CSA C22.2 No. 61730-1 : 2011 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
ISO/IEC 18010:2002 | Information technology Pathways and spaces for customer premises cabling |
IEC 60364-7-714:2011 | Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations |
HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
CSA C22.2 No. 61730-1 : 2011 : INC : AMD 2 : 2015 : R2016 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
UNE-EN 62852:2015 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
I.S. EN 50085-1:2005 | CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
IEC 62626-1:2014 | Low-voltage switchgear and controlgear enclosed equipment - Part 1: Enclosed switch-disconnectors outside the scope of IEC 60947-3 to provide isolation during repair and maintenance work |
01/219359 DC : DRAFT JUNE 2001 | IEC 60364-6-61/A3 ED.1 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 6-61: VERIFICATION - INITIAL VERIFICATION |
BS EN 45510-2-9:2008 | Guide for procurement of power station equipment Electrical equipment. Cabling systems |
IEC 62852:2014 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
DIN VDE 0805 : 1990 AMD 1 1991 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT |
EN 61643-21:2001/A2:2013 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012) |
HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
EN 50521:2008/A1:2012 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
EN 61643-311:2013 | Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT) |
IEC 60364-7-711:2018 RLV | Low-voltage electrical installations - Part 7-711: Requirements for special installations or locations - Exhibitions, shows and stands |
HD 60364-6:2016/AC:2017-11 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION (IEC 60364-6:2016/COR1:2017) |
EN 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
EN 61730-1:2007/A11:2014 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION (IEC 61730-1:2004, MODIFIED) |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
DIN EN 81-20:2014-11 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - LIFTS FOR THE TRANSPORT OF PERSONS AND GOODS - PART 20: PASSENGER AND GOODS PASSENGER LIFTS |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
IEC 60533:2015 RLV | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
HD 384.6.61 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION |
HD 60364-4-442:2012 | Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage system and due to faults in the low voltage system |
EN 60669-2-6:2012 | Switches for household and similar fixed electrical installations - Part 2-6: Particular requirements - Fireman's switches for exterior and interior signs and luminaires |
EN 61643-312 : 2013 | COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 312: SELECTION AND APPLICATION PRINCIPLES FOR GAS DISCHARGE TUBES (IEC 61643-312:2013 + CORRIGENDUM JUL. 2013) |
UNE-HD 60364-7-718:2014 | Low-voltage electrical installations - Part 7-718: Requirements for special installations or locations - Communal facilities and workplaces |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-HD 60364-4-42:2014 | Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects |
UNE-HD 60364-5-52:2014 | Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems |
UNE-HD 60364-5-54:2015 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CISPR 12:2007+AMD1:2009 CSV | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 61024-1:1990 | Protection of structures against lightning - Part 1: General principles |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
CISPR 14-2:2015 RLV | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 61346-1:1996 | Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60721-3-0:1984+AMD1:1987 CSV | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.