View Superseded by

Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-09-2022

Language(s)

English - French, Spanish, Castilian

Published date

25-02-2009

$197.88
Including GST where applicable

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Test apparatus
  4.1 General
  4.2 Ignition source
5 Test procedure
  5.1 Test sample
  5.2 Determination of the number of test pieces
  5.3 Mounting of the test sample
  5.4 Flame application time
6 Evaluation of test results
7 Performance requirements
8 Retest procedure
9 Test report
Annex A (normative) Guidance on cable selection for
        type approval testing
Annex B (informative) Recommended performance
        requirements

IEC 60332-3-23:2000+A1:2008 specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable's ability to limit flame spread. Covers category B and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where medium volumes of non-metallic material are required to be evaluated. A recommended performance requirement is also given. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the first edition (2000) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.

Committee
TC 20
DevelopmentNote
Supersedes IEC 60332-3 (03/2001) Stability Date: 2017. (09/2017)
DocumentType
Standard
Pages
25
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

17/30309558 DC : 0 BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES
KTA 2101.3 : 2015(R2017) FIRE PROTECTION IN NUCLEAR POWER PLANTS - PART 3: FIRE PROTECTION OF MECHANICAL AND ELECTRICAL PLANT COMPONENTS
S.R. HD 60364-4-42:2011 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
DIN EN 12601:2011-07 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
EN 12601:2010 Reciprocating internal combustion engine driven generating sets - Safety
HD 60364-4-42 : 2011 AMD 1 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014)
10/30211242 DC : 0 BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
PREN 12601 : DRAFT 2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
I.S. EN 60695-9-2:2014 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
BS EN 12601:2010 Reciprocating internal combustion engine driven generating sets. Safety
I.S. HD 60364-4-42:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
UNE-EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
IEC TS 60695-9-2:2005 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
IEC 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
UNE-HD 620-10E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5).
UNE-HD 620-9E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5).
UNI EN 12601 : 2011 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
I.S. EN 12601:2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
EA 0052:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
CEI 20-22/0 : 2006 TEST ON ELECTRIC CABLES UNDER FIRE CONDITIONS - PART 0: TEST OF NO PROPAGATION OF FIRE - GENERAL PRINCIPLES
I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
UNE-EN 12601:2011 Reciprocating internal combustion engine driven generating sets - Safety
DD IEC TS 60695-9-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
BS EN 60695-9-2:2014 Fire hazard testing Surface spread of flame. Summary and relevance of test methods
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
UNE-HD 60364-4-42:2014 Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects

AS/NZS IEC 60332.1.2:2017 Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more