IEC 60332-3-23:2000+AMD1:2008 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French, Spanish, Castilian
25-02-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Test apparatus
4.1 General
4.2 Ignition source
5 Test procedure
5.1 Test sample
5.2 Determination of the number of test pieces
5.3 Mounting of the test sample
5.4 Flame application time
6 Evaluation of test results
7 Performance requirements
8 Retest procedure
9 Test report
Annex A (normative) Guidance on cable selection for
type approval testing
Annex B (informative) Recommended performance
requirements
IEC 60332-3-23:2000+A1:2008 specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable's ability to limit flame spread. Covers category B and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where medium volumes of non-metallic material are required to be evaluated. A recommended performance requirement is also given. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the first edition (2000) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 20
|
DevelopmentNote |
Supersedes IEC 60332-3 (03/2001) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
GOST IEC 60332-3-23 : 2011 ERRATA 2015 | Identical |
NEN EN 50266-2-3 : 2001 | Identical |
NEN EN IEC 60332-3-23 : 2009 | Identical |
I.S. EN 60332-3-23:2009 | Identical |
AS/NZS IEC 60332.3.23:2017 | Identical |
PN EN 60332-3-23 : 2009 | Identical |
DIN EN 60332-3-23 : 2010 | Identical |
VDE 0482-332-3-23 : 2010 | Identical |
DIN EN IEC 60332-3-23 :2019 | Identical |
UNE-EN 60332-3-23:2009 | Identical |
BS EN 60332-3-23:2009 | Identical |
CEI EN 60332-3-23 : 2010 | Identical |
EN 60332-3-23:2009 | Identical |
NF EN 60332-3-23 : 2010 | Identical |
17/30309558 DC : 0 | BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES |
KTA 2101.3 : 2015(R2017) | FIRE PROTECTION IN NUCLEAR POWER PLANTS - PART 3: FIRE PROTECTION OF MECHANICAL AND ELECTRICAL PLANT COMPONENTS |
S.R. HD 60364-4-42:2011 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
DIN EN 12601:2011-07 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 12601:2010 | Reciprocating internal combustion engine driven generating sets - Safety |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
10/30211242 DC : 0 | BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
PREN 12601 : DRAFT 2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
I.S. EN 60695-9-2:2014 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 12601:2010 | Reciprocating internal combustion engine driven generating sets. Safety |
I.S. HD 60364-4-42:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
UNE-EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC TS 60695-9-2:2005 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
UNI EN 12601 : 2011 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
I.S. EN 12601:2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
CEI 20-22/0 : 2006 | TEST ON ELECTRIC CABLES UNDER FIRE CONDITIONS - PART 0: TEST OF NO PROPAGATION OF FIRE - GENERAL PRINCIPLES |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
UNE-EN 12601:2011 | Reciprocating internal combustion engine driven generating sets - Safety |
DD IEC TS 60695-9-2 : DRAFT 2005 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
UNE-HD 60364-4-42:2014 | Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects |
AS/NZS IEC 60332.1.2:2017 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60811-1-3:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.