IEC 60332-2-2:2004
Current
The latest, up-to-date edition.
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
15-07-2004
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Procedure
5.1 Sample
5.2 Conditioning
5.3 Positioning of test piece
5.4 Flame application
6 Evaluation of test results
Annex A (informative) Recommended performance requirements
Bibliography
IEC 60332-2-2:2004 Specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in IEC 60332-2-1. This standard gives the procedure for testing small optical fibre cables or a small insulated conductor or cable when the method specified in IEC 60332-1-2 is not suitable because some small optical fibre cables may break or small conductors may melt during the application of the flame. The recommended range of application is for the testing of small single insulated conductors or cables of less than 0,5 mm² cross-section. NOTE Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example, in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.) Recommended requirements for performance are given in Annex A.
Committee |
TC 20
|
DevelopmentNote |
Together with IEC 60332-2-1 supersedes IEC 60332-2. (07/2004) Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
27
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST IEC 60332-2-2 : 2011 ERRATA 2015 | Identical |
NBN EN 60332 2-2 : 2006 | Identical |
NEN EN IEC 60332-2-2 : 2005 | Identical |
I.S. EN 60332-2-2:2004 | Identical |
PN EN 60332-2-2 : 2010 | Identical |
VDE 0482-332-2-2 : 2005 | Identical |
DIN EN 60332-2-2 : 2005 | Identical |
BS EN 60332-2-2:2004 | Identical |
UNE-EN 60332-2-2:2005 | Identical |
CEI EN 60332-2-2 : 2006 | Identical |
EN 60332-2-2:2004 | Identical |
NF EN 60332-2-2 : 2005 | Identical |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
06/30151267 DC : 0 | BS ISO CD 10840 - PLASTICS - GUIDANCE FOR THE USE OF STANDARD FIRE TESTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 : 2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
BS EN 62368-1 : 2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
ISO 10840:2008 | Plastics — Guidance for the use of standard fire tests |
I.S. HD 22.9:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
I.S. EN 60332-1-2:2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
NF EN 62052-31 : 2017 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS |
I.S. EN 60332-2-1:2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - APPARATUS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 :2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
AAMI ES60601-1 : 2005 : INC : AMD 1 : 2012 : R201200 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
AAMI ES60601-1 : 2005 : INC : AMD 2 : 2012 : R201200 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
AAMI ES60601-1 : 2005 : R2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
CSA C22.2 No. 62368-1 : 2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
13/30238229 DC : 0 | BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS |
BS EN 1679-1 : 1998 | RECIPROCATING INTERNAL COMBUSTION ENGINES - SAFETY - PART 1: COMPRESSION IGNITION ENGINES |
DIN EN 12601:2011-07 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
EN 62052-31:2016 | Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests |
EN 50441-1:2012 | Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1 |
EN 12601:2010 | Reciprocating internal combustion engine driven generating sets - Safety |
BS ISO 14885:2014 | Large yachts. Diesel engines for main propulsion and essential auxiliaries. Safety requirements |
03/305960 DC : DRAFT MAY 2003 | EN 60332-2-1 ED. 1 - TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - APPARATUS |
BS ISO 10840:2008 | Plastics. Guidance for the use of standard fire tests |
12/30259316 DC : 0 | BS ISO 14885 - SHIPS AND MARINE TECHNOLOGY - LARGE YACHTS - AUXILIARY DIESEL ENGINES - SAFETY REQUIREMENTS |
PREN 1889-1 : DRAFT 2010 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
BS EN 50441-1:2012 | Cables for indoor residential telecommunication installations Unscreened cables. Grade 1 |
IEC 62368-1:2014 | Audio/video, information and communication technology equipment - Part 1: Safety requirements |
17/30347375 DC : 0 | BS EN 62368-1 ED 3.0 - AUDIO/VIDEO; INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
UNE-EN 60332-2-1:2005 | Tests on electric and optical fibre cables under fire conditions -- Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus |
PREN 12601 : DRAFT 2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
NF EN 61010-1 : 2011 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
AAMI ES60601-1 : 2005 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
I.S. EN 60695-9-2:2014 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
PD IEC/TR 62222:2012 | Fire performance of communication cables installed in buildings |
BS EN 12601:2010 | Reciprocating internal combustion engine driven generating sets. Safety |
I.S. EN 1679-1:1998 | RECIPROCATING INTERNAL COMBUSTION ENGINES - SAFETY - PART 1: COMPRESSION IGNITION ENGINES |
I.S. EN 1889-1:2011 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
I.S. EN 12601:2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
10/30215863 DC : 0 | BS EN 50441-1 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
10/30211242 DC : 0 | BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
02/203871 DC : DRAFT MAR 2002 | IEC 60332-1-2. ED.1 - TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST ON A SINGLE VERTICAL INSULATED WIRE OR CABLE - PROCEDURE |
I.S. EN 60079-14:2014 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
CSA C22.2 No. 61010.1 :2012 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
NFC 32 102-9 : 2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
I.S. EN 60601-1:2006&A1:2013&AC:2014&A12:2014 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
CEI EN 50441-1 : 2013 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
PD IEC/TR 60601-4-3:2015 | Medical electrical equipment Guidance and interpretation. Considerations of unaddressed safety aspects in the third edition of IEC 60601-1 and proposals for new requirements |
PREN 50441-1 : DRAFT 2010 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
CEI EN 60332-2-1 : 2006 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - APPARATUS |
CAN/CSA-C22.2 NO. 61010-1-12 (R2017) | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (Tri-national standard, with UL 61010-1 and ANSI/ISA-61010-1 (82.02.01) |
DIN EN 1679-1:2011-09 | Reciprocating internal combustion engines - Safety - Part 1: Compression ignition engines |
IEC TS 60695-9-2:2005 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
UNE-EN 1889-1:2012 | Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles |
IEC 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
DIN EN 1889-1:2011-10 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
UNE-EN 61010-1:2011 | Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 1: General requirements |
ISA 61010-1 : 2008 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
UNI EN 1889-1 : 2011 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
UNI EN 1679-1 : 2011 | RECIPROCATING INTERNAL COMBUSTION ENGINES - SAFETY - PART 1: COMPRESSION IGNITION ENGINES |
UNI EN 12601 : 2011 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
I.S. EN 50441-1:2012 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
CEI EN 62368-1 : 2016 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
I.S. EN 61010-1:2010/A1:2019 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
10/30182320 DC : 0 | BS EN 1679-1:1998/A1 - RECIPROCATING INTERNAL COMBUSTION ENGINES - SAFETY - PART 1: COMPRESSION IGNITION ENGINES |
12/30258453 DC : 0 | BS EN 62368-1 AMD - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : FR | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62368-1:2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
EN 62368-1:2014/AC:2017-03 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
I.S. EN 61010-1:2010 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
ISO 14885:2014 | Large yachts Diesel engines for main propulsion and essential auxiliaries Safety requirements |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
IEC 62052-31:2015 | Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests |
BS EN 60601-1 : 2006 | MEDICAL ELECTRICAL EQUIPMENT PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
UNE-EN 12601:2011 | Reciprocating internal combustion engine driven generating sets - Safety |
IEC TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use - General requirements for equipment intended to be used in educational establishments by children |
DD IEC TS 60695-9-2 : DRAFT 2005 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC TR 62222:2012 | Fire performance of communication cables installed in buildings |
EN 1889-1:2011 | Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles |
EN 1679-1:1998+A1:2011 | Reciprocating internal combustion engines - Safety - Part 1: Compression ignition engines |
12/30239867 DC : 0 | BS EN 62368-1 - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
10/30185766 DC : 0 | BS EN 1889-1 - MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
BS EN 60332-2-1:2004 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single small insulated wire or cable. Apparatus |
03/305958 DC : DRAFT MAY 2003 | EN 60332-1-2 ED. 1 - TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 :2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62052-31:2016 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 : 2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
BS EN 1889-1:2011 | Machines for underground mines. Mobile machines working underground. Safety Rubber tyred vehicles |
07/30091745 DC : 0 | BS IEC 62368 - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - SAFETY - REQUIREMENTS |
12/30269297 DC : 0 | BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
PD IEC/TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements for equipment intended to be used in educational establishments by children |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
HD 22-9 : 200S3 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
EN 50628:2016 | Erection of electrical installations in underground mines |
EN 60332-2-1:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus |
UNE-EN 1679-1:1998 | RECIPROCATING INTERNAL COMBUSTION ENGINES. SAFETY. PART 1: COMPRESSION IGNITION ENGINES. |
AS/NZS IEC 60332.1.2:2017 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60332-2-1:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.