IEC 60318-6:2007
Current
The latest, up-to-date edition.
Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement on bone vibrators
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
27-11-2007
Describes a mechanical coupler for the measurement of the output force of bone vibrators. The mechanical impedance of the coupler is specified in the frequency range 125 Hz to 8 000 Hz. The coupler is intended for calibration of audiometers using bone vibrators having a plane circular tip area of 175 mm² ± 25 mm² and for determining the performance of bone conduction hearing aids. The vibratory force developed by a bone vibrator is not, in general, the same on the coupler as on a person's mastoid. However, the IEC recommends its use as a means for the calibration of specified vibrators used in audiometry and for the exchange of specifications and of data on bone conduction hearing aids. This standard cancels and replaces IEC 60373 published in 1990. This first edition constitutes a technical revision.
DevelopmentNote |
Supersedes IEC 60373. (11/2007) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
I.S. EN 60318-6:2008 | Identical |
BS EN 60318-6:2008 | Identical |
CEI EN 60318-6 : 2014 | Identical |
UNE-EN 60318-6:2009 | Identical |
NEN EN IEC 60318-6 : 2008 | Identical |
EN 60318-6:2008 | Identical |
PN EN 60318-6 : 2009 | Identical |
NF EN 60318-6 : 2008 | Identical |
08/30189820 DC : DRAFT SEP 2008 | BS EN ISO 8253-1 - ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: BASIC PURE-TONE AIR AND BONE CONDUCTION THRESHOLD AUDIOMETRY |
BS EN ISO 389-9:2009 | Acoustics. Reference zero for the calibration of audiometric equipment Preferred test conditions for the determination of reference hearing threshold levels |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
BS EN ISO 8253-1:2010 | Acoustics. Audiometric test methods Pure-tone air and bone conduction audiometry |
NF EN 60645-3 : 2007 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION |
ANSI S3.6 : 2010 | SPECIFICATION FOR AUDIOMETERS |
14/30313972 DC : 0 | BS EN 60645-1 ED.4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
UNI EN ISO 389-9 : 2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
ISO 389-6:2007 | Acoustics Reference zero for the calibration of audiometric equipment Part 6: Reference threshold of hearing for test signals of short duration |
I.S. EN ISO 8253-1:2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
I.S. EN ISO 389-3:2016 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 3: REFERENCE EQUIVALENT THRESHOLD VIBRATORY FORCE LEVELS FOR PURE TONES AND BONE VIBRATORS (ISO 389-3:2016) |
EN 60645-3:2007 | Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration |
DIN EN ISO 389-9:2009-12 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
15/30328565 DC : 0 | BS EN 60645-1 ED4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
07/30173584 DC : 0 | BS EN 60645-7 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 7: INSTRUMENTS FOR THE MEASUREMENT OF AUDITORY EVOKED POTENTIALS |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
UNE-EN ISO 389-3:2016 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016) |
UNE-EN ISO 8253-1:2011 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
EN ISO 8253-1:2010 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
EN ISO 389-3:2016 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016) |
UNI EN ISO 8253-1 : 2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
CEI EN 60645-3 : 2008 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION |
07/30166205 DC : 0 | BS ISO 389-9 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
08/30176438 DC : DRAFT JAN 2008 | BS EN 60645-1 - ELECTRO ACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: PURE-TONE AUDIOMETERS |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
BS EN 60645-3:2007 | Electroacoustics. Audiometric equipment Test signals of short duration |
I.S. EN ISO 389-9:2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
I.S. EN 60645-3:2007 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
IEC 60645-1:2017 RLV | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 389-9:2009 | Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels |
ISO 389-3:2016 | Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators |
BS EN ISO 389-6:2007 | Acoustics. Reference zero for the calibration of audiometric equipment Reference threshold of hearing for test signals of short duration |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
IEC 60645-3:2007 | Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration |
BS EN ISO 389-3:2016 | Acoustics. Reference zero for the calibration of audiometric equipment Reference equivalent threshold vibratory force levels for pure tones and bone vibrators |
EN ISO 389-9:2009 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
EN ISO 389-6:2007 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 6: Reference threshold of hearing for test signals of short duration (ISO 389-6:2007) |
14/30279048 DC : DRAFT OCT 2014 | BS EN ISO 389-3 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 3: REFERENCE EQUIVALENT THRESHOLD FORCE LEVELS FOR PURE TONES AND BONE VIBRATORS |
DIN EN ISO 389-6:2007-10 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 6: Reference threshold of hearing for test signals of short duration (ISO 389-6:2007) |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 266:1997 | Acoustics — Preferred frequencies |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
IEC 60118-9:1985 | Hearing aids. Part 9: Methods of measurement of characteristics of hearing aids with bone vibrator output |
ISO 389-3:2016 | Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators |
AS/NZS ISO 8253.1:2019 | Acoustics - Audiometric test methods Pure-tone air and bone conduction audiometry |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.