IEC 60317-47:2013
Current
The latest, up-to-date edition.
Specifications for particular types of winding wires - Part 47: Aromatic polyimide enamelled rectangular copper wire, class 240
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
14-10-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative reference
3 Terms, definitions, general notes, and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Bibliography
IEC 60317-47:2013 specifies the requirements of enamelled rectangular copper winding wire of class 240 with a sole coating of aromatic polyimide resin. The range of nominal conductor dimensions covered by this standard is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness, as well as the specified width/thickness ratio, are given in IEC 60317-0-2. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- deletion of the "in some countries" statement in the scope;
- new subclause containing general notes on winding wire, formerly a part of the scope;
- new subclause containing requirements for appearance;
- revision to the notes in Clause 19, Dielectric dissipation factor;
- new Clause 23, Pin hole test. Keywords: requirements of enamelled rectangular copper winding wire, class 240, sole coating of aromatic polyimide resin.
This publication is to be read in conjunction with IEC 60317-0-2:2013.
Committee |
TC 55
|
DevelopmentNote |
To be read in conjunction with IEC 60317-0-2. Stability date: 2018. (10/2013)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60317-47 : 2014 | Identical |
NBN EN 60317-47 : 2014 | Identical |
NEN EN IEC 60317-47 : 2014 | Identical |
I.S. EN 60317-47:2014 | Identical |
PN EN 60317-47 : 2014 | Identical |
BS EN 60317-47:2014 | Identical |
UNE-EN 60317-47:2014 | Identical |
CEI EN 60317-47 : 2014 | Identical |
EN 60317-47:2014 | Identical |
DIN EN 60317-47:2014-10 | Identical |
SN EN 60317-47:2014 | Identical |
DS EN 60317-47 : 2014 | Identical |
SN EN 60317-47 : 1997 | Identical |
BS IEC 61858-2 : 2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
BS EN 61858-2:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS |
I.S. EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
EN 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
12/30273912 DC : 0 | BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS |
NF EN 61858 : 2009 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
BS EN 61858:2008 | Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS |
I.S. EN 61858-2:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
IEC 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
IEC 61858:2008 | Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS |
EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
IEC 60317-0-2:2013 | Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.