IEC 60317-22:2004+AMD1:2009 CSV
Current
The latest, up-to-date edition.
Specifications for particular types of winding wires - Part 22: Polyester or polyesterimide enamelled round copper wire overcoated with polyamide, class 180
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
25-02-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and general notes on methods of test and
appearances
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion (nominal conductor diameters
from 0,250 mm up to and including 2,500 mm)
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
IEC 60317-22:2004+A1:2009 specifies the requirements of enamelled round copper winding wire of class 180 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide resin. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows:
- grade 1: 0,050 mm up to and including 3,150 mm;
- grade 2: 0,050 mm up to and including 5,000 mm;
- grade 3: 0,250 mm up to and including 1,600 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1. The main changes with respect to the previous edition are listed below:
- new requirements for appearance, Subclause 3.2, added;
- breakdown voltage values, former Table 3, replaced with a reference to IEC 60317-0-1;
- new pin hole test, Clause 23, added.
This consolidated version consists of the third edition (2004) and its amendment 1 (2009). Therefore, no need to order amendment in addition to this publication.
This publication is to be read in conjunction with IEC 60317-0-1:2008.
Committee |
TC 55
|
DevelopmentNote |
To be read in conjunction with IEC 60317-0-1. (08/2004) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60317-22 : 2005 AMD 1 2010 | Identical |
NEN EN IEC 60317-22 : 2004 AMD 1 2010 | Identical |
I.S. EN 60317-22:2004 | Identical |
PN EN 60317-22 : 2006 AMD 1 2010 | Identical |
BS EN 60317-22 : 2004 | Identical |
UNE-EN 60317-22:2005 | Identical |
EN 60317-22:2004/A1:2010 | Identical |
DIN EN 60317-22:2010-10 | Identical |
NFC 31 672 : 1988 | Similar to |
NEN 10317-22 : 1995 | Similar to |
UNE 21179-22:1993 | Identical |
HD 555.22 : 200S2 | Similar to |
BS 6811-3.10(1993) : 1993 AMD 9064 | Similar to |
CEI 55-2/22 : 4ED 1991 | Identical |
I.S. EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
NF EN 61858 : 2009 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
12/30273916 DC : 0 | BS EN 61858-1 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-1: WIRE-WOUND WINDING EIS |
BS EN 61858-1:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS |
BS EN 61858:2008 | Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
I.S. EN 61858-1:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 1: WIRE-WOUND WINDING EIS |
IEC 61858-1:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS |
IEC 61858:2008 | Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS |
EN 61858-1:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS |
EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
IEC 60317-0-1:2013 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.