IEC 60289:1988
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Reactors
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
13-12-2007
English - French
15-05-1988
Foreword
Preface
Section 1 - General
1 Scope
2 Definitions
Section 2 - Shunt Reactors
3 General
4 Definitions
5 Rating
6 Insulation level
7 Rating plates
8 Tests
9 Tolerances
Section 3 - Current-Limiting Reactors and Neutral-
Earthing Reactors
10 General
11 Definitions
12 Rating
13 Insulation level
14 Ability to withstand short-time current
15 Temperature rise
16 Rating plates
17 Tests
18 Tolerances
Section 4 - Damping Reactors
19 General
20 Definitions
21 Rating
22 Insulation level
23 Temperature rise
24 Rating plates
25 Tests
26 Tolerances
Section 5 - Tuning (FILTER) Reactors
27 General
28 Definitions
29 Rating
30 Rating plates
31 Tests
32 Tolerances
Section 6 - Earthing Transformers (Neutral Couplers)
33 Introduction
34 General
35 Definitions
36 Rating
37 Ability to withstand the rated neutral current
38 Temperature rise
39 Insulation level
40 Rating plates
41 Tests
42 Tolerances
Section 7 - Arc-Suppression Reactors
43 General
44 Definitions
45 Rating
46 Adjustment range
47 Winding temperature rise
48 Insulation level
49 Rating plates
50 Tests
51 Tolerances
Section 8 - Smoothing Reactors
52 General
53 Definitions
54 Rating
55 Insulation level
56 Temperature rise
57 rating plates
58 Tests
59 Tolerances
Figures
This standard applies to the following types of reactors: shunt reactors, current-limiting reactors including neutral-earthing reactors, damping reactors, tuning (filter) reactors, earthing transformers (neutral couplers), arc-suppression reactors, smoothing reactors, with the exception of the following reactors: small reactors with a rating generally less than 2 kvar single-phase and 10 kvar three-phase, reactors for special purposes such as high-frequency line traps or reactors mounted on rolling stock.
Committee |
TC 14
|
DocumentType |
Standard
|
Pages |
89
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 60289:1994 | Identical |
EN 60289:1994/A11:2002 | Identical |
PN IEC 289 : 1997 | Identical |
AS 1028-1992 | Identical |
NEN EN IEC 60289 : 95 AMD 11 2002 | Identical |
UNE-EN 60289:1995 | Identical |
SN EN 60289 : 1994 AMD 11 2002 | Identical |
VDE 0532-20 : 1994 | Identical |
PN EN 60289 : 2000 AMD 11 2005 | Identical |
BS EN 60289:1995 | Identical |
BS 4944(1994) : 1994 AMD 8405 | Similar to |
HD 539 : S2 CORRIGENDUM | Corresponds |
NF EN 60289 : 96 AMD 11 2002 | Similar to |
BS 4944:1973 | Similar to |
DIN EN 60289 : 2003 | Identical |
NEN EN 60289 : 1995 | Identical |
VDE 0532-289 : 2003 | Identical |
BS IEC 60076-8:1997 | Power transformers Application guide |
BS EN 50216-3:2002 | Power transformer and reactor fittings Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion |
CEI 14-4/8 : 2001 | POWER TRANSFORMERS - APPLICATION GUIDE |
I.S. EN 60551:1993 | DETERMINATION OF TRANSFORMER AND REACTOR SOUND LEVELS |
I.S. EN 61642:1999 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
CEI EN 61800-1 : 2000 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 1: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR LOW VOLTAGE ADJUSTABLE SPEED D.C. POWER DRIVE SYSTEMS |
EN 50216-3 : 2002 AMD 2 2006 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 3: PROTECTIVE RELAY FOR HERMETICALLY SEALED LIQUID-IMMERSED TRANSFORMERS AND REACTORS WITHOUT GASEOUS CUSHION |
EN 61558-2-20:2011 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-20: Particular requirements and tests for small reactors |
EN 61642:1997 | Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors |
BS EN 50299:2002 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment <i>U</i><sub>m</sub> from 72,5 kV to 550 kV |
BS EN 61642:1998 | Industrial a.c. networks affected by harmonics. Application of filters and shunt capacitors |
BS EN 60076-4:2002 | Power transformers Guide to the lightning impulse and switching impulse testing. Power transformers and reactors |
CEI EN 60076-4 : 2003 | POWER TRANSFORMERS - PART 4: GUIDE TO LIGHTNING IMPULSE AND SWITCHING IMPULSE TESTING - POWER TRANSFORMERS AND REACTORS |
I.S. EN 60076-4:2002 | POWER TRANSFORMERS - PART 4: GUIDE TO THE LIGHTNING IMPULSE AND SWITCHING IMPULSE TESTING - POWER TRANSFORMERS AND REACTORS |
VDE 0560-430 : 1998 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
DIN EN 61642 : 1998 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
BS EN 61558-2-20:2011 | Safety of transformers, reactors, power supply units and combinations thereof Particular requirements and tests for small reactors |
CEI EN 61558-2-20 : 2012 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - PART 2-20: PARTICULAR REQUIREMENTS AND TESTS FOR SMALL REACTORS |
CEI EN 60310 : 2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
DD IEC/PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
NF EN 61803 : 2000 AMD 2 2017 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE-COMMUTATED CONVERTERS |
I.S. EN 61558-2-20:2011 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - PART 2-20: PARTICULAR REQUIREMENTS AND TESTS FOR SMALL REACTORS |
IEC PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
EN 50299 : 2002 COR 2004 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV |
NF EN 50216-3 : 2002 AMD 2 2006 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 3: PROTECTIVE RELAY FOR HERMETICALLY SEALED LIQUID-IMMERSED TRANSFORMERS AND REACTORS WITHOUT GASEOUS CUSHION |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 61558-2-20:2010 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-20: Particular requirements and tests for small reactors |
NF EN 50327 : 2005 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
UNE-EN 61558-2-20:2012 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V -- Part 2-20: Particular requirements and tests for small reactors |
EN 60076-4:2002 | Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors |
EN 60551:1992/A1:1997 | DETERMINATION OF TRANSFORMER AND REACTOR SOUND LEVELS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.