IEC 60255-11:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-05-2013
English - French, Spanish, Castilian
08-10-2008
FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Test levels
4.2 Test requirements
5 Test equipment
6 Test set-up
6.1 General
6.2 Voltage dips
6.3 Voltage interruptions
6.4 Alternating component in d.c. (ripple)
6.5 Gradual shut-down/start-up test
6.6 Polarity inversion
7 Test procedure
8 Criteria for acceptance
9 Test report
Bibliography
IEC 60255-11:2008 specifies the general requirements for a.c. and d.c. power supplies, for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to dips, interruptions and alternating components (ripple). The main differences with respect to the previous edition are as follows: addition of voltage dips and interruptions test in a.c.; addition of gradual shut-down/start-up test; addition of reversal of d.c. power supply polarity test.
Committee |
TC 95
|
DevelopmentNote |
Stability Date: 2011. (10/2012)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 60255-11 : 2010 | Identical |
NEN EN IEC 60255-11 : 2010 | Identical |
I.S. EN 60255-11:2010 | Identical |
PN EN 60255-11 : 2010 | Identical |
VDE 0435-3014 : 2010 | Identical |
DIN EN 60255-11 : 2010 | Identical |
BIS IS/IEC 60255-11 : 2008 | Identical |
UNE-EN 60255-11:2010 | Identical |
BS EN 60255-11:2010 | Identical |
CEI EN 60255-11 : 2016 | Identical |
EN 60255-11:2010 | Identical |
UNE 21136-11:1983 | Identical |
PN IEC 255-11 : 1994 | Identical |
05/30136363 DC : DRAFT JUL 2005 | IEC 60255-6 ED 3 - ELECTRICAL RELAYS - PART 6: GENERAL REQUIREMENTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
BS EN 60255-1:2010 | Measuring relays and protection equipment Common requirements |
EN 60255-5:2001 | Electrical relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
VDE 0414-44-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
VDE 0435-303 : 1984 | ELECTRICAL RELAYS; STATIC MEASURING RELAYS (SMR) |
DIN EN 60044-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
CEI EN 60044-7 : 2001 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
07/30163348 DC : 0 | BS EN 60255-26 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS |
EN 60044-7:2000 | Instrument transformers - Part 7: Electronic voltage transformers |
DIN 57435-303 : 1984 | ELECTRICAL RELAYS: STATIC MEASURING RELAYS |
13/30281011 DC : 0 | BS EN 61000-6-5 ED.1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR POWER STATION AND SUBSTATION ENVIRONMENTS |
BS EN 60044-7:2000 | Instrument transformers Electronic voltage transformers |
BS EN 60255-6:1995 | Electrical relays Measuring relays and protection equipment |
BS EN 50263:2000 | Electromagnetic compatibility (EMC). Product standard for measuring relays and protection equipment |
CSA C60044-7 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
DIN EN 50263 : 2000 | |
CSA C60044-7 : 2007 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
CEI EN 60255-1 : 2011 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
UNE-EN 60255-1:2010 | Measuring relays and protection equipment -- Part 1: Common requirements |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
CSA C60044-7 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
00/203618 DC : DRAFT AUG 2000 | IEC 60255-26 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
NF EN 60255-1 : 2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
I.S. EN 60255-1:2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
EN 50263:1999 | Electromagnetic compatibility (EMC) - Product standard for measuring relays and protection equipment |
SEMI F47 : 2006(R2012) | SPECIFICATION FOR SEMICONDUCTOR PROCESSING EQUIPMENT VOLTAGE SAG IMMUNITY |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.