IEC 60146-2:1999
Current
The latest, up-to-date edition.
Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
18-11-1999
Foreword
1 Scope
2 Normative References
3 Definitions
3.1 Functions of converters
3.2 Types of converters
3.3 Converter circuit components
3.4 Important properties of converters and
electronic valve devices
3.5 Disturbances and electromagnetic compatibility
3.6 Characteristics related to input and output
3.7 Definitions of rated values
3.8 Definitions related to cooling
3.9 Definitions related to temperature
3.10 Definitions related to tests
4 Additional Subscripts and Letter Symbols
5 Service Conditions
5.1 Code of identification for cooling methods
5.2 Environmental conditions
5.2.1 Ambient air circulation
5.2.2 Normal service conditions
5.2.3 Unusual environmental service
conditions and design considerations
5.3 Electrical service conditions
5.3.1 Electrical environment specification
5.3.2 Unknown site conditions
5.4 Character of the load
5.5 Immunity requirements
5.5.1 AC supply
5.5.2 DC supply
5.5.3 Load conditions, load unbalance
5.5.4 Electrical unusual service conditions
and performance requirements
6 Rated Values and Additional Characteristics
6.1 General
6.2 Rated values to be specified by the supplier
6.2.1 Rated input values
6.2.2 Rated output values
6.3 Additional characteristics
6.4 Marking
7 Tests
7.1 General
7.1.1 Classification of tests
7.1.2 Performance of tests
7.2 Test schedule for converter equipment and
converter assemblies
7.3 Test specifications
7.3.1 Visual inspection
7.3.2 Checking of auxiliary devices
7.3.3 Insulation test
7.3.4 Checking of the protective devices
7.3.5 Light load and functional test
7.3.6 Rated output test
7.3.7 Overcurrent test
7.3.8 Temperature-rise test
7.3.9 Power loss determination
7.3.10 Measurement of total harmonic
distortion (THD) or total harmonic
factor (THF)
7.3.11 Measurement of power factor
7.3.12 Measurement of output voltage
7.3.13 Confirmation of output voltage
adjustable range
7.3.14 Output voltage unbalance test
7.3.15 Confirmation of output frequency
adjustable range
7.3.16 Output frequency tolerances band test
7.3.17 Checking of the automatic control
7.3.18 Short-circuit test
7.3.19 Measurement of audible noise
7.3.20 Immunity test
7.3.21 Emission test
7.3.22 Measurement of ripple voltage and
current
7.3.23 Additional tests
7.4 Tolerances
Annex A (informative) Example for testing high power
converters
A.1 Introduction
A.2 Basic concepts
A.3 Test procedures
A.3.1 Rated output test
A.3.2 Overcurrent test
A.3.3 Temperature-rise test
A.3.3.1 GTO and diode
A.3.3.2 Snubber circuits
A.3.3.3 DC capacitors
A.3.4 Power loss determination
Figure 1 - Maximum expected overvoltages versus duration of
transient
Figure 2 - Diagram for calculation of voltage unbalance factor
Figure A.1 - Example of a large converter
Figure A.2 - Test circuit of a converter assembly
Figure A.3 - Timing chart for GTO gate pulses
Table 1 - Immunity levels for stiff a.c. voltage connections
Table 2 - DC voltage tolerances
Table 3 - Relative peak-to-peak ripple factor
Table 4 - Test items
Table 5 - Tolerances of losses and efficiency
Applies to all types of semiconductor inverters of the self-commutated type and semiconductor convertors which contain at least one part of a self-commutated type, including direct a.c. convertors and d.c. convertors for all applications.
Committee |
TC 22
|
DevelopmentNote |
Supersedes IEC 60146, IEC 60146-3 (03/2001) Also numbered as BS EN 60146-2. (09/2005) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
91
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60146-2 : 2002 | Identical |
NEN EN IEC 60146-2 : 2000 | Identical |
I.S. EN 60146-2:2003 | Identical |
PN EN 60146-2 : 2001 | Identical |
SAC GB/T 3859-4 : 2004 | Identical |
SN EN 60146-2 : 2000 | Identical |
AS 60146.2-2001 | Identical |
DIN EN 60146-2 : 2001 | Identical |
VDE 0558-2 : 2001 | Identical |
UNE-EN 60146-2:2000 | Identical |
CEI EN 60146-2 : 2001 | Identical |
EN 60146-2:2000 | Identical |
PNE-EN 60146-2 | Identical |
NFC 53 221 : 1980 | Identical |
14/30295243 DC : 0 | BS EN 62909-1 ED 1.0 - BI-DIRECTIONAL GRID CONNECTED POWER CONVERTERS - PART 1: GENERAL REQUIREMENTS |
NF EN 62040-5-3 : 2017 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS |
16/30296073 DC : 0 | BS EN 62924 ED 1.0 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - STATIONARY ENERGY STORAGE SYSTEM FOR DC TRACTION SYSTEMS |
09/30186728 DC : 0 | BS EN 62040-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
BS EN 62924:2017 | Railway applications. Fixed installations. Stationary energy storage system for DC traction systems |
14/30297921 DC : 0 | BS EN 62040-5-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS FOR D.C. UPS |
I.S. EN 61800-3:2005 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004 (EQV)) |
09/30214359 DC : 0 | BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
07/30158043 DC : 0 | BS EN 62501 - ELECTRICAL TESTING OF VOLTAGE SOURCE CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION |
CEI EN 50328 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
BS EN 50533 : 2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
DD ENV 50091-3:1999 | Specification for uninterruptible power systems (UPS) Performance requirements and test methods |
S.R. HD 60364-4-41:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
IEC TR 60919-1:2010+AMD1:2013 CSV | Performance of high-voltage direct current (HVDC) systems withline-commutated converters - Part 1: Steady-state conditions |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
IEC 62909-1:2017 | Bi-directional grid connected power converters - Part 1: General requirements |
I.S. EN 50328:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
EN 61683:2000 | Photovoltaic systems - Power conditioners - Procedure for measuring efficiency |
EN 62040-5-3:2017 | Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements |
EN 62747:2014/AC:2015 | TERMINOLOGY FOR VOLTAGE-SOURCED CONVERTERS (VSC) FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) SYSTEMS (IEC 62747:2014) |
BS EN 62747:2014 | Terminology for voltage-sourced converters (VSC) for high-voltage direct current (HVDC) systems |
BS 7674:1993 | Nuclear power plants. Instrumentation and control systems important for safety. Requirements for electrical supplies |
I.S. EN 62747:2014-2015-10 | TERMINOLOGY FOR VOLTAGE-SOURCED CONVERTERS (VSC) FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) SYSTEMS |
00/244020 DC : DRAFT SEP 2000 | IEC 61800-3 ED.2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS PRODUCT STANDARD INCLUDING SPECIFIC TEST METHODS |
13/30278886 DC : 0 | BS EN 60092-501 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 501: SPECIAL FEATURES - ELECTRIC PROPULSION PLANT |
BS EN 62040-5-3:2017 | Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements |
BS IEC 60092-304:1980 | Electrical installation in ships Equipment. Semiconductor convertors |
BS EN 61800-3 : 2004 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS |
BS EN 61683:2000 | Photovoltaic systems. Power conditioners. Procedure for measuring efficiency |
I.S. EN 62040-5-3:2017 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS |
CLC/TR 60919-1:2005 | Performance of high-voltage direct current (HVDC) systems with line-commutated converters - Part 1: Steady-state conditions |
EN IEC 62909-1:2018 | Bi-directional grid-connected power converters - Part 1: General requirements |
I.S. EN 60146-1-1:2010 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
IEC 62590:2010 | Railway applications - Fixed installations - Electronic power converters for substations |
I.S. EN 62040-3:2011 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
17/30354643 DC : 0 | BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
BS 5486-1:1986 | Low-voltage switchgear and controlgear assemblies. Specification for type-tested and partially type-tested assemblies (general requirements) |
BS 5486-1:1990 | Low-voltage switchgear and controlgear assemblies Requirements for type-tested and partially type-tested assemblies |
DIN IEC/TR 62543 : 2018 | HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION USING VOLTAGE SOURCED CONVERTERS (VSC) (IEC/TR 62543:2011 + A1:2013 + A2:2017) |
VDE 0553-543 : 2018 | HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION USING VOLTAGE SOURCED CONVERTERS (VSC) (IEC/TR 62543:2011 + A1:2013 + A2:2017) |
DIN VDE 0559-4 : 1988 | POWER CONVERTERS FOR ROLLING STOCK - DIRECT D.C. CONVERTERS (D.C. CHOPPER CONVERTERS) |
12/30251416 DC : 0 | BS EN 62747 - TERMINOLOGY FOR VOLTAGE-SOURCED CONVERTERS (VSC) FOR HVDC SYSTEMS |
BS PD IEC TR 60919-1 : 2010 | PERFORMANCE OF HIGH-VOLTAGE DIRECT CURRENT (HVDC) SYSTEMS WITH LINE-COMMUTATED CONVERTERS - PART 1: STEADY-STATE CONDITIONS |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
BS EN 50328:2003 | Railway applications. Fixed installations. Electronic power convertors for substations |
BS 7698-12:1998 | Reciprocating internal combustion engine driven alternating current generating sets Emergency power supply to safety devices |
00/203525 DC : DRAFT AUG 2000 | IEC 60364-4-41 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - SECTION 41: PROTECTION AGAINST ELECTRIC SHOCK |
01/219357 DC : DRAFT MAY 2001 | IEC 60364-4-41 ED.5.0 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
BS PD IEC TR 62543 : 2011 | HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION USING VOLTAGE SOURCED CONVERTERS (VSC) |
EN 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
I.S. EN 50533:2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
PD IEC/TR 60146-1-2:2011 | Semiconductor converters. General requirements and line commutated converters Application guide |
EN IEC 62933-2-1:2018 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
EN 62501:2009/A2:2017 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING (IEC 62501:2009/A2:2017) |
IEC 60092-501:2013 | Electrical installations in ships - Part 501: Special features - Electric propulsion plant |
BS IEC 60092-501:2013 | Electrical installations in ships Special features. Electric propulsion plant |
EN 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
I.S. EN IEC 62933-2-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
I.S. HD 60364-4-41:2007 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
I.S. EN 61683:2000 | PHOTOVOLTAIC SYSTEMS - POWER CONDITIONERS - PROCEDURE FOR MEASURING EFFICIENCY |
I.S. EN IEC 62909-1:2018 | BI-DIRECTIONAL GRID-CONNECTED POWER CONVERTERS - PART 1: GENERAL REQUIREMENTS |
IEC 62501:2009+AMD1:2014+AMD2:2017 CSV | Voltage sourced converter (VSC) valves for high-voltage direct current (HVDC) power transmission - Electrical testing |
I.S. CLC TR 60919-1:2005 | PERFORMANCE OF HIGH-VOLTAGE DIRECT CURRENT (HVDC) SYSTEMS WITH LINE-COMMUTATED CONVERTERS - PART 1: STEADY-STATE CONDITIONS |
IEC 62933-2-1:2017 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
IEEE 1662-2008 | IEEE Guide for the Design and Application of Power Electronics in Electrical Power Systems on Ships |
IEEE 2030.1.1-2015 | IEEE Standard Technical Specifications of a DC Quick Charger for Use with Electric Vehicles |
IEC 61800-4:2002 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
NF EN 50533 : 2012 AMD 1 2018 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
CEI EN 61683 : 2001 | PHOTOVOLTAIC SYSTEMS - POWER CONDITIONERS PROCEDURE FOR MEASURING EFFICIENCY |
DIN V ENV 50091-3 : 2000 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: PERFORMANCE REQUIREMENTS |
BS EN 62501 : 2009 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
04/30115723 DC : DRAFT JUN 2004 | |
15/30321124 DC : 0 | BS EN 60364-4-41 ED 5.0 /A1 - LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
I.S. EN 62501:2009 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
CEI EN 62040-5-3 : 1ED 2017 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS |
UNE-EN 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
BS EN 62040-3:2011 | Uninterruptible power systems (UPS) Method of specifying the performance and test requirements |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
CEI EN 60146-1-1 : 2013 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
IEC TR 60146-1-2:2011 | Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide |
IEC TS 61800-8:2010 | Adjustable speed electrical power drive systems - Part 8: Specification of voltage on the power interface |
I.S. EN 60439-1:2000 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
DD IEC/TS 61800-8:2010 | Adjustable speed electrical power drive systems Specification of voltage on the power interface |
IEC 62040-5-3:2016 | Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
BS EN 60439-1:1999 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
10/30230568 DC : 0 | BS EN 61892-3 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
14/30279327 DC : 0 | BS EN 61800-3 AMD2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS |
UNE-EN 50533:2012 | Railway applications - Three-phase train line voltage characteristics. |
BS EN 61800-4:2003 | Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV |
PREN 50533 : DRAFT 2009 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
06/30156472 DC : DRAFT SEP 2006 | BS EN 60146-1-1 - SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
BS EN 60146-1-1:2010 | Semiconductor converters. General requirements and line commutated converters Specification of basic requirements |
I.S. EN 62924:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - STATIONARY ENERGY STORAGE SYSTEM FOR DC TRACTION SYSTEMS |
BS IEC 61225:2005 | Nuclear power plants. Instrumentation and control systems important to safety. Requirements for electrical supplies |
CEI UNI EN 45510-2-2 : 1999 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-2: ELECTRICAL EQUIPMENT - UNINTERRUPTIBLE POWER SUPPLIES |
EN 50328 : 2003 COR 2006 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
IEC 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
CEI EN 61800-4 : 2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
I.S. EN 61800-4:2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
IEC TR 62543:2011+AMD1:2013 CSV | High-voltage direct current (HVDC) power transmission using voltage sourced converters (VSC) |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
BS EN 45510-2-2:1999 | Guide for the procurement of power station equipment. Electrical equipment Uninterruptible power supplies - Uninterruptible power supplies for power plants |
DIN VDE 0660-500 : 1991 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - REQUIREMENTS FOR TYPE-TESTED AND PARTIALLY TYPE-TESTED ASSEMBLIES |
ENV 50091-3 : 98 AMD 1 99 | UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
EN 61800-4:2003 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
EN 50533 : 2011 AMD 1 2016 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
CEI EN IEC 61800-3:2024 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60747-1:2006+AMD1:2010 CSV | Semiconductor devices - Part 1: General |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.