IEC 60141-1:1993
Current
The latest, up-to-date edition.
Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-09-1993
FOREWORD
Clause
SECTION 1: GENERAL
1.1 Scope
1.2 Normative references
1.3 Definitions and symbols
1.4 Voltage designation
1.5 Test conditions
1.6 Characteristics
1.7 Categories and frequency of tests
SECTION 2: ROUTINE TESTS ON CABLES
2.1 General
2.2 Conductor resistance test
2.3 Capacitance test
2.4 Dielectric loss angle test
2.5 High-voltage test
2.6 Test on corrosion-resistant coverings
SECTION 3: SPECIAL TESTS ON CABLES
3.1 Measurements of thickness
3.2 Mechanical test
SECTION 4: TYPE TESTS ON CABLES
4.1 General
4.2 Test requirements
4.3 Dielectric loss angle/temperature test
4.4 Dielectric security test
4.5 Lightning impulse voltage test
SECTION 5: ROUTINE TESTS ON ACCESSORIES
5.1 General
5.2 Joint and sealing-end assemblies
5.3 Pressure tanks - Hydraulic test
5.4 Pressure gauges
5.5 Alarm pressure gauges
SECTION 6: SPECIAL TESTS ON ACCESSORIES
6.1 Pressure tanks - Pressure/volume test
SECTION 7: TYPE TESTS ON ACCESSORIES
7.1 General
7.2 Test requirement
7.3 Lightning impulse voltage test
7.4 Dielectric security test
SECTION 8: TESTS AFTER INSTALLATION
8.1 General
8.2 Oil-flow test
8.3 Impregnation coefficient
8.4 High-voltage test
8.5 Test on corrosion-resistant coverings
Tables
1 Dielectric loss angle test requirements
2 Standard values of system voltages and test
voltages recommended for cables to be used
in three-phase systems
Annex A - Methods of heating cable samples
Applies to tests on radial field, oil-filled, paper-insulated, metal-sheathed cables and their accessories, which operate with a minimum static pressure of between 20 kPa (0.2 bar) and 300 kPa (3.0 bar) inclusive, a maximum static pressure of not more than 800 kPa (8.0 bar) and a minimum transient pressure of not less than 20 kPa (0.2 bar). The quoted pressures are above atmospheric pressure. Includes routine, special and type tests on cables and accessories as well as tests after installation. Gives details of methods of heating cable samples.
DevelopmentNote |
Stability Date: 2020. (10/2012)
|
DocumentType |
Standard
|
Pages |
61
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST R IEC 141-1 : 1996 | Identical |
BS EN 60695-1-40:2014 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids |
HD 633 S1:1997 | Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV) |
BS EN 62271-203:2012 | High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
BS EN 60517:1997 | Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
I.S. EN 62271-209:2007 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
BS EN 62271-209:2007 | High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations |
UNE-EN 62271-203:2013 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 60695-1-40:2013 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
NF EN 62271-209 : 2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY TYPE CABLE-TERMINATIONS |
BS 6904:1987 | Guide for cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
BIS IS/IEC 62271-203 : 2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 50299:2004 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV |
CEI EN 62271-209 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
08/30179468 DC : DRAFT MAR 2008 | BS EN 62271-203 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
12/30269145 DC : 0 | BS EN 60695-1-40 ED 1.0 - FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
IEC TS 60859:1999 | Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations |
I.S. EN 60695-1-40:2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
UNE-EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
IEC TS 60695-1-40:2002 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEEE 400.4-2015 | IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage |
CEI EN 62271-203 : 2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
CEI EN 60695-1-40 : 2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
I.S. HD 633:1999 | TESTS ON OIL-FILLED (FLUID FILLED), PAPER- OR POLYPROPYLENE PAPER LAMINATED-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV) |
I.S. EN 62271-203:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV)) |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.