IEC 60076-21:2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power transformers - Part 21: Standard requirements, terminology, and test code for step-voltage regulators

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

31-12-2021

Superseded by

IEC 60076-21:2018

Language(s)

English

Published date

15-12-2011

$650.16
Including GST where applicable

1. Overview
2. Normative references
3. Definitions
4. Service conditions
5. Rating data
6. Construction
7. Other requirements
8. Test code
9. Control systems
Annex A (informative) - Unusual temperature and altitude
        conditions
Annex B (informative) - Field dielectric tests
Annex C (informative) - Bibliography
Annex D (informative) - IEEE List of Participants

IEC 60076-21:2011/IEEE Std C57.15:2009 - Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed single and three-phase step-voltage regulators are described. Winding resistance measurements, polarity tests, insulation power factor and resistance tests, ratio tests, no load loss and excitation current measurements, impedance and load loss measurements, dielectric tests, temperature tests, routine and design impulse tests, short-circuit tests, control tests, calculated data, and certified test data are covered.

DevelopmentNote
Also numbered as IEEE C57.15. (12/2011)
DocumentType
Standard
Pages
103
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
IS 2026 : Part 21 : 2018 Identical
BS IEC 60076-21:2011 Identical
NEN IEC 60076-21 : 2012 Identical

13/30265253 DC : 0 BS EN 60214-1 ED 2 - TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
BS EN 60214-1:2014 Tap-changers Performance requirements and test methods
NF EN 60214-1 : 2015 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
UNE-EN 60214-1:2015 Tap-changers - Part 1: Performance requirements and test methods
I.S. EN 60214-1:2014 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
EN 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods

IEC 60255-22-1:2007 Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests
IEEE 62-1995 IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
IEC 60255-22-5:2008 Measuring relays and protection equipment - Part 22-5: Electrical disturbance tests - Surge immunity test
IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
IEEE C37.90.3-2001 IEEE Standard Electrostatic Discharge Tests for Protective Relays
IEEE C57.104-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers
IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
IEC 60255-22-6:2001 Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields
IEC 60255-22-3:2007 Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
IEC 60255-5:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests
IEEE C57.12.20-2011 REDLINE IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below
IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
IEC 60255-22-2:2008 Measuring relays and protection equipment - Part 22-2: Electrical disturbance tests - Electrostatic discharge tests
IEC 60255-21-1:1988 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)
IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEEE C57.106-2006 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
IEC 60214-2:2004 Tap-changers - Part 2: Application guide
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
IEC 60255-22-4:2008 Measuring relays and protection equipment - Part 22-4: Electrical disturbance tests - Electrical fast transient/burst immunity test
IEEE C57.131-2012 IEEE Standard Requirements for Tap Changers
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more