IEC 60076-1:2011
Current
The latest, up-to-date edition.
Power transformers - Part 1: General
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French, Spanish, Castilian
20-04-2011
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Rating and general requirements
6 Requirements for transformers having a tapped winding
7 Connection phase displacement symbols
8 Rating plates
9 Safety, environmental and other requirements
10 Tolerances
11 Tests
12 Electromagnetic compatibility (EMC)
13 High frequency switching transients
Annex A (informative) - Check list of information to be
provided with enquiry and order
Annex B (informative) - Examples of specifications for
transformers with tappings
Annex C (informative) - Specification of short-circuit
impedance by boundaries
Annex D (informative) - Examples of three-phase transformer
connections
Annex E (normative) - Temperature correction of load loss
Annex F (informative) - Facilities for future fitting of
condition monitoring systems to
transformers
Annex G (informative) - Environmental and safety
considerations
Bibliography
IEC 60076-1:2011 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers. For those categories of power transformers and reactors which have their own IEC standards, this part is applicable only to the extent in which it is specifically called up by cross-reference in the other standard. This new edition includes the following significant technical additions with respect to the previous one:
- definition of harmonic content;
- subclause on transport;
- functional method of specification;
- connection symbols for single phase transformers;
- safety and environmental requirements;
- requirements for liquid preservation systems;
- clause on DC currents;
- vacuum, pressure and leak tests on tanks;
- facilities for condition monitoring and environmental and safety considerations.
Committee |
TC 14
|
DevelopmentNote |
Supersedes IEC 60076-4. (03/2001) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
ISBN |
978-2-88912-438-1
|
Pages |
152
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60076-1 : 2012 | Identical |
NEN EN IEC 60076-1 : 2011 | Identical |
I.S. EN 60076-1:2011 | Identical |
PN EN 60076-1 : 2011 | Identical |
VDE 0532-76-1 : 2012 | Identical |
DIN EN 60076-1 : 2012 | Identical |
UNE-EN 60076-1:2013 | Identical |
CEI EN 60076-1 : 2015 | Identical |
EN 60076-1:2011 | Identical |
BS EN 60076-1:2011 | Identical |
VDE 0532-101 : 97 AMD 1 2001 | Identical |
UNE 20101-1:1981 | Identical |
BS EN 60076-11:2004 | Power transformers Dry-type transformers |
IEC 61643-352:2018 | Components for low-voltage surge protection - Part 352: Selection and application principles for telecommunications and signalling network surge isolation transformers (SITs) |
BS IEC 60076-15:2015 | Power transformers Gas-filled power transformers |
NF EN 61116 : 2003 | ELECTROMECHANICAL EQUIPMENT GUIDE FOR SMALL HYDROELECTRIC INSTALLATIONS |
BS EN 50216-2:2002 | Power transformers and reactor fittings Gas and oil actuated relay for liquid immersed transformers and reactors with conservator |
BS EN 60076-13:2006 | Power transformers Self-protected liquid-filled transformers |
BS EN 61803 : 1999 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE-COMMUTATED CONVERTERS (IEC 61803:1999) |
BS EN 60143-4:2010 | Series capacitors for power systems Thyristors controlled series capacitors |
15/30324519 DC : 0 | BS EN ISO 14224 - PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
BS EN 50329 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
09/30187488 DC : DRAFT AUG 2009 | BS EN 60076-16 - POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION |
CEI EN 60076-14 : 2014 | POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
CEI EN 61400-22 : 2011 | WIND TURBINES - PART 22: CONFORMITY TESTING AND CERTIFICATION |
07/30170365 DC : DRAFT AUG 2007 | BS EN 60076-2 - POWER TRANSFORMERS - PART 2: TEMPERATURE-RISE FOR OIL-IMMERSED TRANSFORMERS |
I.S. EN 60726:2003 | DRY-TYPE POWER TRANSFORMERS |
BS EN 50216-1:2002 | Power transformers and reactor fittings General |
PD IEC TS 60076-20:2017 | Power transformers Energy efficiency |
BS EN 50216-7:2002 | Power transformers and reactor fittings Electric pumps for transformer oil |
17/30347294 DC : 0 | BS EN 60076-22-1 - POWER TRANSFORMER AND REACTOR FITTINGS - PART 22-1: PROTECTIVE DEVICES |
UNE-EN 50541-1:2012 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
UNE-EN 61378-1:2012 | Convertor transformers -- Part 1: Transformers for industrial applications |
BS IEC/IEEE 65700-19-03 : 2014 | BUSHINGS FOR DC APPLICATION |
12/30263868 DC : 0 | BS EN 60076-14 - POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
CEI 14-4/8 : 2001 | POWER TRANSFORMERS - APPLICATION GUIDE |
PD IEC/TR 63042-100:2016 | UHV AC transmission systems General information |
I.S. EN 60143-4:2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
CEI EN 50216-7 : 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 7: ELECTRIC PUMPS FOR TRANSFORMER OIL |
CEI EN 61116 : 1996 | ELECTROMECHANICAL EQUIPMENT GUIDE FOR SMALL HYDROELECTRIC INSTALLATIONS |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
CEI EN 61378-2 : 2002 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
I.S. EN 60076-11:2004 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. EN 60076-16:2011 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011) |
I.S. EN 60137:2017 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
I.S. EN 62271-212:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS) |
I.S. EN 60076-14:2013 | POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV)) |
I.S. EN 61248-1:1998 | TRANSFORMERS AND INDUCTORS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - PART 1: GENERIC SPECIFICATION |
IEC 61378-3:2015 | Converter transformers - Part 3: Application guide |
NF EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION |
EN 60137:2017 | Insulated bushings for alternating voltages above 1 000 V |
NF EN 60076-13 : 2007 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
I.S. EN 61116:1995 | ELECTROMECHANICAL EQUIPMENT GUIDE FOR SMALL HYDROELECTRIC INSTALLATIONS |
IEC TS 60076-14:2009 | Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials |
UNE-EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
BS EN 61558-1 : 2005 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
11/30253145 DC : 0 | BS EN 62271-202 ED2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
EN 50216-2 : 2002 AMD 1 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR |
EN 50216-1:2002 | Power transformer and reactor fittings - Part 1: General |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 60214:1997 | On-load tap-changers |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 61968-11:2013 | Application integration at electric utilities - System interfaces for distribution management - Part 11: Common information model (CIM) extensions for distribution |
EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
EN 62271-212:2017 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
EN 60289:1994/A11:2002 | REACTORS |
DEFSTAN 08-107/3(2013) : 2013 | GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROTECHNICAL AND NAVAL WEAPON EQUIPMENT |
EN 60726:2003 | Dry-type power transformers |
04/30111589 DC : 0 | |
BS IEC 60076-8:1997 | Power transformers Application guide |
BS EN 60076-2:2011 | Power transformers Temperature rise for liquid-immersed transformers |
CEI EN 61968-11 : 2013 | APPLICATION INTEGRATION AT ELECTRIC UTILITIES - SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT - PART 11: COMMON INFORMATION MODEL (CIM) EXTENSIONS FOR DISTRIBUTION |
16/30336914 DC : 0 | BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS |
DEFSTAN 02-607/2(2008) : 2008 | DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY |
BS EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV General requirements |
02/205931 DC : DRAFT MAY 2002 | IEC 60214-2. ED.1 - TAP CHANGERS - PART 2: APPLICATION GUIDE |
13/30265253 DC : 0 | BS EN 60214-1 ED 2 - TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS |
BS EN 60076-10:2016 | Power transformers Determination of sound levels |
BS EN 60076-14:2013 | Power transformers Liquid-immersed power transformers using high-temperature insulation materials |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
11/30245197 DC : 0 | BS EN 60143-2 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENTS FOR SERIES CAPACITOR BANKS |
CEI EN 60076-5 : 2007 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT |
CEI EN 60076-3 : 2015 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
BS 7806:1995 | Dry-type power transformers |
I.S. EN 60076-13:2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
BS EN 60076-6:2008 | Power transformers Reactors |
BS EN 50541-1:2011 | Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements |
NF EN 61378-1 : 2014 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS |
EN 61643-351:2017 | Components for low-voltage surge protective devices - Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) |
02/211941 DC : 0 | IEC 60076-14 ED.1 - GUIDE FOR THE DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
BS IEC 61378-3:2015 | Converter transformers Application guide |
UNE-EN 60076-14:2014 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
BS PD IEC TS 60076-19 : 2013 | POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
18/30368743 DC (published 2018-04) | BS EN 60947-6-2. Low-voltage switchgear and controlgear Part 6-2. Multiple function equipment. Control and protective switching devices (or equipment) (CPS) |
NF EN 60076-10 : 2017 | POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
08/30178668 DC : DRAFT FEB 2008 | BS EN 61378-1 - CONVERTER TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS |
NF EN 60289 : 96 AMD 11 2002 | REACTORS |
IEEE 1031-2011 | IEEE Guide for the Functional Specification of Transmission Static Var Compensators |
CEI EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS |
CEI 14-41 : 2011 | TAP-CHANGERS - PART 2: APPLICATION GUIDE |
NF EN 61558-1 : 2006 AMD 1 2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60092-303:1980 | Electrical installations in ships - Part 303: Equipment - Transformers for power and lighting |
BS EN 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
I.S. EN IEC 61643-352:2018 | COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTION - PART 352: SELECTI AND APPLICATION PRINCIPLES FOR TELECOMMUNICATIONS AND SIGNALLIN NETWORK SURGE ISOLATION TRANSFORMERS (SITS) |
CEI EN 50216-1 : 2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL |
I.S. EN 62271-202:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
I.S. EN 60076-5:2006 | POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT-CIRCUIT |
IEC 60076-7:2018 | Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers |
CEI EN 60076-10 : 2002 | POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
IEC 62695:2014 | Railway applications - Fixed installations - Traction transformers |
DIN EN 15869-3:2010-06 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
CEI 14-42 : 2011 | CONVERTER TRANSFORMERS - PART 3: APPLICATION GUIDE |
CEI EN 61378-1 : 2012 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS |
NF EN 60076-6 : 2008 | POWER TRANSFORMERS - PART 6: REACTORS |
NF EN 50329 : 2005 AMD 1 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
CEI EN 60143-4 : 2012 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
BIS IS 14786 : 2000(R2015) | HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATIONS |
I.S. EN 60146-1-1:2010 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
IEC 61643-351:2016 | Components for low-voltage surge protective devices - Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) |
I.S. EN 61803:1999 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS |
I.S. EN 50216-12:2011 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 12: FANS |
IEC/IEEE 65700-19-03:2014 | Bushings for DC application |
UNE-EN 50216-12:2011 | Power transformer and reactor fittings - Part 12: Fans |
15/30297998 DC : 0 | BS EN 62271-212 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS) |
17/30354643 DC : 0 | BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
IEC 60137:2017 RLV | Insulated bushings for alternating voltages above 1000 V |
EN 50216-12:2011 | Power transformer and reactor fittings - Part 12: Fans |
BS 4571:1994 | On-load tap-changers |
VDE 0532-20 : 1994 | REACTORS |
VDE 0532-42 : 2001 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
BS 4571:1978 | Specification for on-load tap-changers |
CEI EN 60076-2 : 2015 | POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS |
BS IEC 60092-303:1980 | Electrical installation in ships Equipment. Transformers for power and lighting |
DEFSTAN 02-607/3(2013) : 2013 | DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY |
CEI EN 61803 : 2011 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS |
BS 5622-1:1979 | Guide for insulation co-ordination Terms, definitions, principles and rules |
17/30331680 DC : 0 | BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS |
11/30251812 DC : 0 | BS EN 61968-11 - APPLICATION INTEGRATION AT ELECTRIC UTILITIES - SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT - PART 11: COMMON INFORMATION MODEL (CIM) EXTENSIONS FOR DISTRIBUTION |
10/30232718 DC : 0 | BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
13/30295873 DC : DRAFT DEC 2013 | BS EN 60076-20 - POWER TRANSFORMERS - PART 20: ENERGY EFFICIENCY |
UNE-EN 60137:2011 | Insulated bushings for alternating voltages above 1 000 V |
I.S. EN 60143-2:2013 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV)) |
BS EN 60214:1998 | On-load tap-changers |
BS EN 60214-1:2014 | Tap-changers Performance requirements and test methods |
IEEE 1861-2014 | IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above |
CEI EN 50541-1 : 2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
14/30271248 DC : 0 | BS EN 60310 ED 4.0 - RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
CCS GUIDELINE E-07 : DEC 2017 | TRANSFORMERS |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
05/30133866 DC : DRAFT MAY 2005 | IEC 60076-6 - POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 50216-2:2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR |
BS EN 60143-2:2013 | Series capacitors for power systems Protective equipment for series capacitor banks |
IEC/IEEE 60076-57-129:2017 | Power transformers - Part 57-129: Transformers for HVDC applications |
BS EN 60289:1995 | Reactors |
CEI EN 60143-2 : 2014 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS |
EN IEC 62933-2-1:2018 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
I.S. EN 60076-19:2015 | POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
I.S. EN 61643-351:2017 | COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 351: PERFORMANCE REQUIREMENTS AND TEST METHODS FOR TELECOMMUNICATIONS AND SIGNALLING NETWORK SURGE ISOLATION TRANSFORMERS (SIT) |
BS EN 15869-3:2010 | Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz On-board unit, safety requirements |
I.S. EN 50541-1:2011 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
PREN 50541-1 : DRAFT 2009 | THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
NF EN 61803 : 2000 AMD 2 2017 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE-COMMUTATED CONVERTERS |
IEC TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
UNE-EN 60076-19:2016 | Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
I.S. EN 60076-6:2008 | POWER TRANSFORMERS - PART 6: REACTORS |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 62032:2012 | Guide for the Application, Specification and Testing of Phase-Shifting Transformers |
I.S. EN 60076-10:2016 | POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
IEC 60076-3:2013+AMD1:2018 CSV | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
IEC 62933-2-1:2017 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
UNE-EN 62271-202:2015 | High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation |
IEC 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
UNE-EN 60947-4-1:2011 | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 61800-4:2002 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
ISO 14224:2016 | Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment |
UNE-EN 61400-22:2011 | Wind turbines - Part 22: Conformity testing and certification |
EN 50532:2010 | Compact Equipment Assembly for Distribution Substations (CEADS) |
I.S. EN 60076-3:2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
BS EN 61800-4:2003 | Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV |
NF EN 60076-19 : 2016 | POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
PD IEC/TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
BS EN 60076-5:2006 | Power transformers Ability to withstand short-circuit |
BS EN 61968-11:2013 | Application integration at electric utilities. System interfaces for distribution management Common information model (CIM) extensions for distribution |
I.S. EN 50532:2010 | COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
BS EN 61378-1:2011 | Convertor transformers Transformers for industrial applications |
BS EN 60076-16:2011 | Power transformers Transformers for wind turbines applications |
BS EN 61248-1:1997 | Transformers and inductors for use in electronic and telecommunication equipment Generic specification |
06/30156472 DC : DRAFT SEP 2006 | BS EN 60146-1-1 - SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
UNE-EN 60076-16:2012 | Power transformers - Part 16: Transformers for wind turbines applications |
11/30253149 DC : 0 | BS EN 60076-10 ED2 - POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS |
BS EN 60726:2003 | Dry-type power transformers |
DIN VDE 0660-102 : 1992 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS |
16/30318517 DC : 0 | BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
09/30206330 DC : 0 | BS EN 61803:1999+A1 - DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS |
CSA C22.2 NO. 60947-4-1:14 (R2019) | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1) |
BS EN IEC 61643-352:2018 | Components for low-voltage surge protection Selection and application principles for telecommunications and signalling network surge isolation transformers (SITs) |
EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
I.S. EN 60076-2:2011 | POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS |
I.S. EN 61968-11:2013 | APPLICATION INTEGRATION AT ELECTRIC UTILITIES - SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT - PART 11: COMMON INFORMATION MODEL (CIM) EXTENSIONS FOR DISTRIBUTION (IEC 61968-11:2013 (EQV)) |
EN IEC 61643-352:2018 | Components for low-voltage surge protection - Part 352: Selection and application principles for telecommunications and signalling network surge isolation transformers (SITs) |
I.S. EN 15869-3:2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
I.S. EN 50216-1:2002 | POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL |
ISO 18095:2018 | Condition monitoring and diagnostics of power transformers |
CEI EN 60146-1-1 : 2013 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
CEI EN 60076-6 : 2015 | POWER TRANSFORMERS - PART 6: REACTORS |
IEC 60214-2:2004 | Tap-changers - Part 2: Application guide |
IEC TS 60076-19:2013 | Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
I.S. EN 61558-1:2006 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60076-15:2015 | Power transformers - Part 15: Gas-filled power transformers |
IEC TR 63042-100:2016 | UHV AC transmission systems - Part 100: General information |
EN 61803:1999/A2:2016 | DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS (IEC 61803:1999/A2:2016) |
BS EN 62271-212:2017 | High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS) |
IEC 61116:1992 | Electromechanical equipment guide for small hydroelectric installations |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
BS EN 50532:2010 | Compact equipment assembly for distribution substations (CEADS) |
EN 61400-22:2011 | Wind turbines - Part 22: Conformity testing and certification |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 61076-4-102:1997 | Connectors with assessed quality for use in d.c., low-frequencyanalogue and in digital high speed data applications - Part 4:Printed board connectors - Section 102: Detail specification fortwo-part single-pole connectors, for multiple uses on plug-inunits, with pre-centring, coding and early mating features, havinga metric grid in accordance with IEC 60917 |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 61803:1999+AMD1:2010+AMD2:2016 CSV | Determination of power losses in high-voltage direct current (HVDC)converter stations with line-commutated converters |
15/30328159 DC : 0 | BS EN 61558-1 - SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60143-2:2012 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 62271-212:2016 | High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS) |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEC 62271-202:2014 | High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation |
09/30202403 DC : 0 | BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS) |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
UNE-EN 50532:2011 | Compact Equipment Assembly for Distribution Substations (CEADS) |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
UNE-EN 60076-2:2013 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
EN 15869-3:2010 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements |
DD IEC TS 60076-14 : DRAFT 2009 | POWER TRANSFORMERS - PART 14: DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
09/30211604 DC : 0 | BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV |
BS EN 60947-4-1 : 2010 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS |
FM 3990 : 2018 | LESS OR NONFLAMMABLE LIQUID-INSULATED TRANSFORMERS |
CEI EN 60076-13 : 2007 | POWER TRANSFORMERS - PART 13: SELF PROTECTED LIQUID FILLED TRANSFORMERS |
IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
BS EN 50216-12:2011 | Power transformer and reactor fittings Fans |
CEI CLC/TR 50462 : 2009 | RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
CEI EN 60076-11 : 2006 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. HD 428.1:1992 | THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
BS EN 61378-2:2001 | Convertor transformers Transformers for HVDC applications |
CEI EN 60310 : 2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
BS EN 60076-19:2015 | Power transformers Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
BS EN 61643-351:2017 | Components for low-voltage surge protective devices Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) |
13/30281716 DC : 0 | BS EN 50299-2 - OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
16/30349321 DC : 0 | BS EN 60076-11 ED 2.0 - POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
12/30267005 DC : 0 | BS IEC 60076-19 TS ED.1 - POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
CLC/TR 50462:2008 | Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
BS EN 60146-1-1:2010 | Semiconductor converters. General requirements and line commutated converters Specification of basic requirements |
04/30117440 DC : DRAFT JUL 2004 | IEC 60076-13. ED.1 - POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID FILLED TRANSFORMERS |
C88-16 | Power transformers and reactors |
BS EN 60076-3 : 2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
API 689 : 2007 | COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
UNE-EN 15869-3:2011 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements |
I.S. EN 60551:1993 | DETERMINATION OF TRANSFORMER AND REACTOR SOUND LEVELS |
I.S. EN IEC 62933-2-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
IEEE C57.135-2011 | IEEE Guide for the Application, Specification, and Testing of Phase-Shifting Transformers |
UNE-EN 60076-10:2017 | Power transformers - Part 10: Determination of sound levels |
CEI 14-47 : 2012 | POWER TRANSFORMERS - LOADING GUIDE FOR DRY-TYPE POWER TRANSFORMERS |
NF EN 60310 : 2017 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
I.S. EN 60947-4-1:2010 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009 (EQV)) |
I.S. EN 50329:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
I.S. EN 61378-1:2011 | CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011) |
CEI EN 60137 : 2009 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
UNE-EN 60214-1:2015 | Tap-changers - Part 1: Performance requirements and test methods |
UNI EN 15869-3 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS |
UNE-IEC 60076-12:2010 | Power transformers - Part 12: Loading guide for dry-type power transformers |
BIS IS/IEC 60947-4-1 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4: CONTACTORS AND MOTOR-STARTERS - SECTION 1: ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS |
CEI EN 61800-4 : 2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
I.S. EN 60214-1:2014 | TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS |
I.S. EN 61400-22:2011 | WIND TURBINES - PART 22: CONFORMITY TESTING AND CERTIFICATION |
I.S. EN 61800-4:2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
S.R. CLC/TR 50462:2008 | RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS |
IEC 61400-22:2010 | Wind turbines - Part 22: Conformity testing and certification |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
02/714212 DC : DRAFT DEC 2002 | IEC 62271-202 ED.1 - HIGH VOLTAGE/LOW VOLTAGE PREFABRICATED SUBSTATIONS |
IEC 61968-11:2013 | Application integration at electric utilities - System interfaces for distribution management - Part 11: Common information model (CIM) extensions for distribution |
BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
BS EN 62271-202:2014 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
HD 428.1 S1:1992/AC:2011 | THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
EN 60076-13 : 2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 60076-19:2015 | Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors |
EN 61248-1 : 1997 | Transformers and inductors for use in electronic and telecommunication equipment - Part 1: Generic specification |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
EN 61800-4:2003 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
EN 60143-4 : 2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
EN 60143-2:2013 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
EN 60551:1992/A1:1997 | DETERMINATION OF TRANSFORMER AND REACTOR SOUND LEVELS |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
EN 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
EN 60076-3:2013/A1:2018 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR (IEC 60076-3:2013/A1:2018) |
EN 61116:1994 | Electromechanical equipment guide for small hydroelectric installations |
CAN/CSA-E61558-1:12 (R2017) | Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d\'inductance et produits analogues - Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada) |
BS 4944(1994) : 1994 AMD 8405 | REACTORS |
CSA E61558.1:2012 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
NBR ISO 14224 : 2011 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT |
CSA E61558.1 : 2012 : INC : UPD 1 : 2014 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60076-15:2015 | Power transformers - Part 15: Gas-filled power transformers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC TR 60616:1978 | Terminal and tapping markings for power transformers |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 62032:2012 | Guide for the Application, Specification and Testing of Phase-Shifting Transformers |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
IEEE C57.142 : 2010 | GUIDE TO DESCRIBE THE OCCURRENCE AND MITIGATION OF SWITCHING TRANSIENTS INDUCED BY TRANSFORMERS, SWITCHING DEVICE, AND SYSTEM INTERACTION |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC TS 60076-14:2009 | Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
IEC 60076-10-1:2016 | Power transformers - Part 10-1: Determination of sound levels - Application guide |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.