I.S. ETS 300 158:1993
Current
The latest, up-to-date edition.
SATELLITE EARTH STATIONS (SES); TELEVISION RECEIVE ONLY (TVRO-FSS) SATELLITE EARTH STATIONS OPERATING IN THE 11/12 GHZ FSS BANDS
Hardcopy , PDF
English
01-01-1993
Foreword
1 Scope
2 Normative references
3 Definitions
4 General conditions for measurement
4.1 General
5 Requirements
5.1 General
5.2 Safety
5.3 Local Oscillator(s) (LO) frequency
5.4 Radiation from the outdoor unit
5.5 Immunity
5.6 Documentation
6 Recommendation
6.1 Documentation
6.2 Radio frequency input range(s)
6.3 Intermediate Frequency (IF) output range
6.4 Figure of merit
6.5 Radiation from outdoor unit
6.6 Antenna sub-system
6.7 Low-Noise Block (LNB) down-converter
6.8 Internal immunity to unwanted signals
6.9 Power supply
6.10 Commands waveguides [13a]
Annex A (normative): General conditions for
measurement
A.1 Standard atmospheric conditions
A.2 Power supply
A.3 Test site
A.4 Accuracy of the measuring instruments
A.5 Stabilisation period
A.6 Presentation of results
A.7 Deviations
A.8 Radio-frequency input signals
Annex B (normative): Radiation measurement in the
frequency range from 1 GHz to
18 GHz
B.1 Measuring equipment
B.2 Measuring set-u
B.3 Site checking and calibration
B.4 Measurement procedure
B.5 Presentation of the results
Annex C (normative): Radiation measurements in the
frequency range from 30 to 1000
MHz
C.1 Introduction
C.2 Measurements in the frequency range 30 MHz - 300
MHz
C.3 Measurements in the frequency range 300 - 1000 MHz
Annex D (normative): Measurement of G/T ratio by direct
method
D.1 Introduction
D.2 Method of measurement
Annex E (normative): Antenna sub-system noise
temperature measurement method
Annex F (informative): G/T ratio (clear sky conditions)
F.1 G/T ratio indirect measurement
F.2 G/T calculation for a particular antenna
Annex G (informative): Protection ratio
Annex H (informative): Dimensions in millimetres of
waveguide flanges
H.1 Dimensions of Type B flanges in millimetres for
ordinary rectangular
H.2 Dimensions of flanges in millimetres for
circular waveguides [13b]
Annex J (informative): Installation
History
Gives minimum specifications for the standardization of the technical characteristics of satellite receiving earth stations, capable of receiving audio visual signals and associated data.
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
ETS 300 158 : 20001 | Identical |
EN 50081-1:1992 | Electromagnetic compatibility - Generic emission standard - Part 1: Residential, commercial and light industry |
IEC 60107-1:1997 | Methods of measurement on receivers for television broadcast transmissions - Part 1: General considerations - Measurements at radio and video frequencies |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60695-1-1:1999 | Fire hazard testing - Part 1-1: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
IEC 60510-1:1975 | Methods of measurement for radio equipment used in satellite earth stations. Part 1: General |
IEC 60510-1-2:1984 | Methods of measurement for radio equipment used in satellite earth stations. Part 1: Measurements common to sub-systems and combinations of sub-systems. Section Two: Measurements in the r.f. range |
HD 444.2.3 : 200S1 | FIRE HAZARD TESTING - TEST METHODS - BAD CONNECTION TEST WITH HEATERS |
CISPR 16:1987 | CISPR specification for radio interference measuring apparatus and measurement methods |
IEC 60510-1-5:1988 | Methods of measurement for radio equipment used in satellite earth stations. Part 1: Measurements common to sub-systems and combinations of sub-systems. Section Five: Noise temperature measurements |
IEC 60154-4:2017 | Flanges for waveguides - Part 4: Relevant specifications for flanges for circular waveguides |
EN 55020:2007/A12:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006) |
HD 444.2.2 : 200S2 | FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST |
IEC 61079-1:1992 | Methods of measurement on receivers for satellite broadcasttransmissions in the 12 GHz band - Part 1: Radio-frequencymeasurements on outdoor units |
HD 444.2.1 : 200S1 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST AND GUIDANCE |
IEC 60154-2:2016 | Flanges for waveguides - Part 2: Relevant specifications for flanges for ordinary rectangular waveguides |
IEC 60510-1A:1980 | Methods of measurement for radio equipment used in satellite earth stations. Part 1: Measurements common to sub-systems and combinations of sub-systems. First supplement: Sub-clause 6.2: D.C. source conditions |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50082-1:1997 | Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry |
IEC 60510-2-4:1988 | Methods of measurement for radio equipment used in satellite earth stations. Part 2: Measurements for sub-systems. Section Four: Up- and down-converters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.