I.S. EN ISO 25539-3:2011
Current
The latest, up-to-date edition.
CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 3: VENA CAVA FILTERS (ISO 25539-3:2011)
Hardcopy , PDF
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Intended performance
6 Design attributes
7 Materials
8 Design evaluation
9 Post-market surveillance
10 Manufacturing
11 Sterilization
12 Packaging
Annex A (informative) - Attributes of endovascular devices
- Vena cava filters - Technical and clinical
considerations
Annex B (informative) - Descriptions of potential device
effects of failure and failure modes and descriptions
of detrimental clinical effects
Annex C (informative) - Bench and analytical tests
Annex D (informative) - Test methods
Annex E (informative) - Examples of terms for clinical use
of vena cava filters
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 93/42/EEC
Describes requirements for vena cava filters, based upon current medical knowledge.
DevelopmentNote |
Supersedes I.S. EN 12006-3. (01/2012)
|
DocumentType |
Standard
|
Pages |
107
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN ISO 25539-3:2011 | Identical |
ISO 25539-3:2011 | Identical |
ISO 11070:2014 | Sterile single-use intravascular introducers, dilators and guidewires |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 10555-2:1996 | Sterile, single-use intravascular catheters Part 2: Angiographic catheters |
ASTM F 2503 : 2013 : REDLINE | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ISO 17475:2005 | Corrosion of metals and alloys — Electrochemical test methods — Guidelines for conducting potentiostatic and potentiodynamic polarization measurements |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO/TR 14969:2004 | Medical devices Quality management systems Guidance on the application of ISO 13485: 2003 |
ASTM G 71 : 1981 | GUIDE FOR CONDUCTING AND EVALUATING GALVANIC CORROSION TESTS IN ELECTROLYTES |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 14630:2012 | Non-active surgical implants — General requirements |
ASTM F 2052 : 2015 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ISO/TS 15539:2000 | Cardiovascular implants Endovascular prostheses |
ASTM F 2213 : 2017 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ISO/TS 12417:2011 | Cardiovascular implants and extracorporeal systems Vascular device-drug combination products |
EN 12006-3:1998+A1:2009 | Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 3: Endovascular devices |
ISO 10555-3:2013 | Intravascular catheters — Sterile and single-use catheters — Part 3: Central venous catheters |
CFR 21(PTS1-99) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 1-99 |
ISO 10555-1:2013 | Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
ASTM F 640 : 2012 : REDLINE | Standard Test Methods for Determining Radiopacity for Medical Use |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.