I.S. EN 845-2:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS
Hardcopy , PDF
26-07-2022
English
04-06-2013
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Materials
5 Requirements
6 Description and designation
7 Marking
8 Assessment and verification of constancy of
performance - AVCP
Annex A (informative) - Method for assessment of loads
on lintels
Annex B (informative) - Recommendations for installation
of lintels
Annex C (normative) - Corrosion protection systems
Annex D (informative) - Guidance on FPC frequencies
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the EU
Construction Products Regulation
Bibliography
Describes requirements for prefabricated lintels for maximum spans of 4,5 m and made from steel, autoclaved aerated concrete, manufactured stone, concrete, fired clay units, calcium silicate units, natural stone units, or a combination of these materials.
DevelopmentNote |
Supersedes I.S. 240 & I.S. 255. (11/2011) 2013 Edition Re-Issued in August 2016 & incorporates AMD 1 2016. (08/2016)
|
DocumentType |
Standard
|
Pages |
46
|
ProductNote |
CSV version for this is now available.
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NEN EN 845-2 : 2013 + A1 2016 | Identical |
SN EN 845-2 : 2013 + A1 2016 | Identical |
UNE-EN 845-2:2005 | Identical |
DIN EN 845-2:2013-08 | Identical |
NF EN 845-2 : 2013 + A1 2016 | Identical |
NS EN 845-2 : 2013 + A1 2016 | Identical |
UNI EN 845-2 : 2013 | Identical |
BS EN 845-2 : 2013 | Identical |
NBN EN 845-2 : 2013 | Identical |
EN 845-2:2013+A1:2016 | Identical |
DIN EN 845-2:2003-08 | Identical |
S.R. 325:2013+A2:2018/AC:2019 | RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES IN IRELAND TO EUROCODE 6 |
EN 846-13:2001 | Methods of test for ancillary components for masonry - Part 13: Determination of resistance to impact, abrasion and corrosion of organic coatings |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 12602:2016 | Prefabricated reinforced components of autoclaved aerated concrete |
EN 998-2:2016 | Specification for mortar for masonry - Part 2: Masonry mortar |
ISO 12491:1997 | Statistical methods for quality control of building materials and components |
EN ISO 1463:2004 | Metallic and oxide coatings - Measurement of coating thickness - Microscopical method (ISO 1463:2003) |
EN 13225:2013 | Precast concrete products - Linear structural elements |
CEN/TS 772-22:2006 | Methods of test for masonry units - Part 22: Determination of freeze/thaw resistance of clay masonry units |
EN 846-9:2016 | Methods of test for ancillary components for masonry - Part 9: Determination of flexural resistance and shear resistance of lintels |
EN 846-14:2012 | Methods of test for ancillary components for masonry - Part 14: Determination of the initial shear strength between the prefabricated part of a composite lintel and the masonry above it |
EN 10111:2008 | Continuously hot rolled low carbon steel sheet and strip for cold forming - Technical delivery conditions |
EN 772-1:2011+A1:2015 | Methods of test for masonry units - Part 1: Determination of compressive strength |
EN 10346:2015 | Continuously hot-dip coated steel flat products for cold forming - Technical delivery conditions |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
EN 846-7:2012 | Methods of test for ancillary components for masonry - Part 7: Determination of shear load capacity and load displacement characteristics of shear ties and slip ties (couplet test for mortar joint connections) |
EN 1745:2012 | Masonry and masonry products - Methods for determining thermal properties |
EN 846-10:2000 | Methods of test for ancillary components for masonry - Part 10: Determination of load capacity and load deflection characteristics of brackets |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 10080:2005 | Steel for the reinforcement of concrete - Weldable reinforcing steel - General |
EN 1090-1:2009+A1:2011 | Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components |
EN 1996-1-1:2005+A1:2012 | Eurocode 6 - Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures |
EN 12620:2002+A1:2008 | Aggregates for concrete |
EN 990:2002 | Test methods for verification of corrosion protection of reinforcement in autoclaved aerated concrete and lightweight aggregate concrete with open structure |
EN 846-5:2012 | Methods of test for ancillary components for masonry - Part 5: Determination of tensile and compressive load capacity and load displacement characteristics of wall ties (couplet test) |
EN 10130:2006 | Cold rolled low carbon steel flat products for cold forming - Technical delivery conditions |
EN 846-2:2000 | Methods of test for ancillary components for masonry - Part 2: Determination of bond strength of prefabricated bed joint reinforcement in mortar joints |
EN 846-3:2000 | Methods of test for ancillary components for masonry - Part 3: Determination of shear load capacity of welds in prefabricated bed joint reinforcement |
EN 772-11:2011 | Methods of test for masonry units - Part 11: Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units |
EN 846-11:2000 | Methods of test for ancillary components for masonry - Part 11: Determination of dimensions and bow of lintels |
EN 846-6:2012 | Methods of test for ancillary components for masonry - Part 6: Determination of tensile and compressive load capacity and load displacement characteristics of wall ties (single end test) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.