I.S. EN 62772:2016
Current
The latest, up-to-date edition.
COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
Hardcopy , PDF
English
01-01-2016
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and marking
5 Environmental conditions
6 Information on transport, storage and
installation
7 Classification of tests
8 Design tests
9 Type tests
10 Sample tests
11 Routine tests
12 Documentation
Annex A (informative) - Water diffusion test
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to composite hollow core station post insulators consisting of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler material a housing made of polymeric material and metal fixing devices at the ends of the insulating tube.
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
SupersededBy |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
ISO 1101:2017 | Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 62231:2006 | Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria |
EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 62231:2006 | Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria |
EN 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |