I.S. EN 61400-1:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
WIND TURBINES - PART 1: DESIGN REQUIREMENTS
Hardcopy , PDF
23-04-2019
English
01-01-2005
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
4.1 Symbols and units
4.2 Abbreviations
5 Principal elements
5.1 General
5.2 Design methods
5.3 Safety classes
5.4 Quality assurance
5.5 Wind turbine markings
6 External conditions
6.1 General
6.2 Wind turbine classes
6.3 Wind conditions
6.4 Other environmental conditions
6.5 Electrical power network conditions
7 Structural design
7.1 General
7.2 Design methodology
7.3 Loads
7.4 Design situations and load cases
7.5 Load calculations
7.6 Ultimate limit state analysis
8 Control and protection system
8.1 General
8.2 Control functions
8.3 Protection functions
8.4 Braking system
9 Mechanical systems
9.1 General
9.2 Errors of fitting
9.3 Hydraulic or pneumatic systems
9.4 Main gearbox
9.5 Yaw system
9.6 Pitch system
9.7 Protection function mechanical brakes
9.8 Rolling bearings
10 Electrical system
10.1 General
10.2 General requirements for the electrical system
10.3 Protective devices
10.4 Disconnect devices
10.5 Earth system
10.6 Lightning protection
10.7 Electrical cables
10.8 Self-excitation
10.9 Protection against lightning electromagnetic impulse
10.10 Power quality
10.11 Electromagnetic compatibility
11 Assessment of a wind turbine for site-specific conditions
11.1 General
11.2 Assessment of the topographical complexity of the site
11.3 Wind conditions required for assessment
11.4 Assessment of wake effects from neighbouring wind
turbines
11.5 Assessment of other environmental conditions
11.6 Assessment of earthquake conditions
11.7 Assessment of electrical network conditions
11.8 Assessment of soil conditions
11.9 Assessment of structural integrity by reference to
wind data
11.10 Assessment of structural integrity by load
calculations with reference to site specific
conditions
12 Assembly, installation and erection
12.1 General
12.2 Planning
12.3 Installation conditions
12.4 Site access
12.5 Environmental conditions
12.6 Documentation
12.7 Receiving, handling and storage
12.8 Foundation/anchor systems
12.9 Assembly of wind turbine
12.10 Erection of wind turbine
12.11 Fasteners and attachments
12.12 Cranes, hoists and lifting equipment
13 Commissioning, operation and maintenance
13.1 General
13.2 Design requirements for safe operation, inspection
and maintenance
13.3 Instructions concerning commissioning
13.4 Operator's instruction manual
13.5 Maintenance manual
Annex A (normative) Design parameters for describing wind
turbine class S
Annex B (informative) Turbulence models
Annex C (informative) Assessment of earthquake loading
Annex D (informative) Wake and wind farm turbulence
Annex E (informative) Prediction of wind distribution for
wind turbine sites by measure-correlate-predict (MCP)
methods
Annex F (informative) Statistical extrapolation of loads for
ultimate strength analysis
Annex G (informative) Fatigue analysis using Miner's rule
with load extrapolation
Annex H (informative) Contemporaneous loads
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Specifies essential design requirements to ensure the engineering integrity of wind turbines. Provides an appropriate level of protection against damage from all hazards during the planned lifetime.
DevelopmentNote |
Supersedes I.S. ENV 61400-1 (04/2004) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
128
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 61400-1:2005+AMD1:2010 CSV | Identical |
UNE-EN 61400-1:2006 | Identical |
EN 61400-1:2005/A1:2010 | Identical |
NF EN 61400-1 : 2006 AMD 1 2015 | Identical |
BS EN 61400-1 : 2005 | Identical |
NBN EN 61400-1 : 2006 AMD 1 2011 | Identical |
DIN EN 61400-1 : 2011 | Identical |
SN EN 61400-1 : 2005 | Identical |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60038:2009 | IEC standard voltages |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 61400-2:2014 | Wind turbines - Part 2: Small wind turbines |
IEC 60898:1995 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations |
ISO 3010:2017 | Bases for design of structures — Seismic actions on structures |
IEC 61310-2:2007 | Safety of machinery - Indication, marking and actuation - Part 2: Requirements for marking |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
ISO 6336-2:2006 | Calculation of load capacity of spur and helical gears Part 2: Calculation of surface durability (pitting) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
ISO 4354:2009 | Wind actions on structures |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
ISO 2394:2015 | General principles on reliability for structures |
IEC 60204-11:2000 | Safety of machinery - Electrical equipment of machines - Part 11: Requirements for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV |
ISO 6336-3:2006 | Calculation of load capacity of spur and helical gears Part 3: Calculation of tooth bending strength |
ISO 2533:1975 | Standard Atmosphere |
HD 478.2.1 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - TEMPERATURE AND HUMIDITY |
ISO 281:2007 | Rolling bearings Dynamic load ratings and rating life |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN 61400-21:2008 | WIND TURBINES - PART 21: MEASUREMENT AND ASSESSMENT OF POWER QUALITY CHARACTERISTICS OF GRID CONNECTED WIND TURBINES |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
ISO 81400-4:2005 | Wind turbines Part 4: Design and specification of gearboxes |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 61400-2:2013 | Wind turbines - Part 2: Small wind turbines |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
ISO 8930:1987 | General principles on reliability for structures List of equivalent terms |
EN 60204-11:2000/corrigendum:2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 61310-1:2007 | Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
IEC 60173:1964 | Colours of the cores of flexible cables and cords |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 76:2006 | Rolling bearings Static load ratings |
EN 60204-1 : 2006 COR 2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
IEC 61400-21:2008 | Wind turbines - Part 21: Measurement and assessment of power quality characteristics of grid connected wind turbines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.